110 research outputs found

    An Intermediate-mass Black Hole of Over 500 Solar Masses in the Galaxy ESO 243-49

    Full text link
    Ultra-luminous X-ray sources are extragalactic objects located outside the nucleus of the host galaxy with bolometric luminosities >10^39 erg s^-1. These extreme luminosities - if the emission is isotropic and below the theoretical (i.e. Eddington) limit, where the radiation pressure is balanced by the gravitational pressure - imply the presence of an accreting black hole with a mass of ~10^2-10^5 times that of the Sun. The existence of such intermediate mass black holes is in dispute, and though many candidates have been proposed, none are widely accepted as definitive. Here we report the detection of a variable X-ray source with a maximum 0.2-10 keV luminosity of up to 1.2 x 10^42 erg s^-1 in the edge-on spiral galaxy ESO 243-49, with an implied conservative lower limit of the mass of the black hole of ~500 Msun. This finding presents the strongest observational evidence to date for the existence of intermediate mass black holes, providing the long sought after missing link between the stellar mass and super-massive black hole populations.Comment: 5 pages, 2 figures, 1 table, published in Natur

    Angular and Current-Target Correlations in Deep Inelastic Scattering at HERA

    Get PDF
    Correlations between charged particles in deep inelastic ep scattering have been studied in the Breit frame with the ZEUS detector at HERA using an integrated luminosity of 6.4 pb-1. Short-range correlations are analysed in terms of the angular separation between current-region particles within a cone centred around the virtual photon axis. Long-range correlations between the current and target regions have also been measured. The data support predictions for the scaling behaviour of the angular correlations at high Q2 and for anti-correlations between the current and target regions over a large range in Q2 and in the Bjorken scaling variable x. Analytic QCD calculations and Monte Carlo models correctly describe the trends of the data at high Q2, but show quantitative discrepancies. The data show differences between the correlations in deep inelastic scattering and e+e- annihilation.Comment: 26 pages including 10 figures (submitted to Eur. J. Phys. C

    TNFA-863 polymorphism is associated with a reduced risk of Chronic Obstructive Pulmonary Disease: A replication study

    Get PDF
    <p/> <p>Background</p> <p>TNF-α mediated inflammation is thought to play a key role in the respiratory and systemic features of Chronic Obstructive Pulmonary Disease. The aim of the present study was to replicate and extend recent findings in Taiwanese and Caucasian populations of associations between COPD susceptibility and variants of the <it>TNFA </it>gene in a Spanish cohort.</p> <p>Methods</p> <p>The 3 reported SNPs were complemented with nine tag single nucleotide polymorphisms (SNP) of the <it>TNFA </it>and <it>LTA </it>genes and genotyped in 724 individuals (202 COPD patients, 90 smokers without COPD and 432 healthy controls). Pulmonary function parameters and serum inflammatory markers were also measured in COPD patients.</p> <p>Results</p> <p>The <it>TNFA </it>rs1800630 (-863C/A) SNP was associated with a lower COPD susceptibility (ORadj = 0.50, 95% CI = 0.33-0.77, p = 0.001). The -863A allele was also associated with less severe forms of the disease (GOLD stages I and II) (ORadj = 0.303, 95%CI = 0.14-0.65, p = 0.014) and with lower scores of the BODE index (< 2) (ORadj = 0.40, 95%CI = 0.17-0.94, p = 0.037). Moreover, the -863A carrier genotype was associated with a better FEV<sub>1 </sub>percent predicted (p = 0.004) and a lower BODE index (p = 0.003) over a 2 yrs follow-up period. None of the <it>TNFA </it>or <it>LTA </it>gene variants correlated with the serum inflammatory markers in COPD patients (p > 0.05).</p> <p>Conclusions</p> <p>We replicated the previously reported association between the <it>TNFA </it>-863 SNP and COPD. <it>TNFA </it>-863A allele may confer a protective effect to the susceptibility to the disease in the Spanish population.</p

    Change in albuminuria as a surrogate endpoint for progression of kidney disease: a meta-analysis of treatment effects in randomised clinical trials

    Get PDF
    Background Change in albuminuria has strong biological plausibility as a surrogate endpoint for progression of chronic kidney disease, but empirical evidence to support its validity is lacking. We aimed to determine the association between treatment effects on early changes in albuminuria and treatment effects on clinical endpoints and surrograte endpoints, to inform the use of albuminuria as a surrogate endpoint in future randomised controlled trials. Methods In this meta-analysis, we searched PubMed for publications in English from Jan 1, 1946, to Dec 15, 2016, using search terms including “chronic kidney disease”, “chronic renal insufficiency”, “albuminuria”, “proteinuria”, and “randomized controlled trial”; key inclusion criteria were quantifiable measurements of albuminuria or proteinuria at baseline and within 12 months of follow-up and information on the incidence of end-stage kidney disease. We requested use of individual patient data from the authors of eligible studies. For all studies that the authors agreed to participate and that had sufficient data, we estimated treatment effects on 6-month change in albuminuria and the composite clinical endpoint of treated end-stage kidney disease, estimated glomerular filtration rate of less than 15 mL/min per 1·73 m2, or doubling of serum creatinine. We used a Bayesian mixed-effects meta-regression analysis to relate the treatment effects on albuminuria to those on the clinical endpoint across studies and developed a prediction model for the treatment effect on the clinical endpoint on the basis of the treatment effect on albuminuria. Findings We identified 41 eligible treatment comparisons from randomised trials (referred to as studies) that provided sufficient patient-level data on 29 979 participants (21 206 [71%] with diabetes). Over a median follow-up of 3·4 years (IQR 2·3–4·2), 3935 (13%) participants reached the composite clinical endpoint. Across all studies, with a meta-regression slope of 0·89 (95% Bayesian credible interval [BCI] 0·13–1·70), each 30% decrease in geometric mean albuminuria by the treatment relative to the control was associated with an average 27% lower hazard for the clinical endpoint (95% BCI 5–45%; median R2 0·47, 95% BCI 0·02–0·96). The association strengthened after restricting analyses to patients with baseline albuminuria of more than 30 mg/g (ie, 3·4 mg/mmol; R2 0·72, 0·05–0·99]). For future trials, the model predicts that treatments that decrease the geometric mean albuminuria to 0·7 (ie, 30% decrease in albuminuria) relative to the control will provide an average hazard ratio (HR) for the clinical endpoint of 0·68, and 95% of sufficiently large studies would have HRs between 0·47 and 0·95. Interpretation Our results support a role for change in albuminuria as a surrogate endpoint for the progression of chronic kidney disease, particularly in patients with high baseline albuminuria; for patients with low baseline levels of albuminuria this association is less certain

    Topical antibiotics as a major contextual hazard toward bacteremia within selective digestive decontamination studies: a meta-analysis

    Get PDF

    Communication methods and production techniques in fixed prosthesis fabrication: a UK based survey. Part 2: Production techniques

    Get PDF
    Aim The aim of this study was to identify the communication methods and production techniques used by dentists and dental technicians for the fabrication of fixed prostheses within the UK from the dental technicians' perspective. This second paper reports on the production techniques utilised.Materials and methods Seven hundred and eighty-two online questionnaires were distributed to the Dental Laboratories Association membership and included a broad range of topics, such as demographics, impression disinfection and suitability, and various production techniques. Settings were managed in order to ensure anonymity of respondents. Statistical analysis was undertaken to test the influence of various demographic variables such as the source of information, the location, and the size of the dental laboratory.Results The number of completed responses totalled 248 (32% response rate). Ninety percent of the respondents were based in England and the majority of dental laboratories were categorised as small sized (working with up to 25 dentists). Concerns were raised regarding inadequate disinfection protocols between dentists and dental laboratories and the poor quality of master impressions. Full arch plastic trays were the most popular impression tray used by dentists in the fabrication of crowns (61%) and bridgework (68%). The majority (89%) of jaw registration records were considered inaccurate. Forty-four percent of dental laboratories preferred using semi-adjustable articulators. Axial and occlusal under-preparation of abutment teeth was reported as an issue in about 25% of cases. Base metal alloy was the most (52%) commonly used alloy material. Metal-ceramic crowns were the most popular choice for anterior (69%) and posterior (70%) cases. The various factors considered did not have any statistically significant effect on the answers provided. The only notable exception was the fact that more methods of communicating the size and shape of crowns were utilised for large laboratories.Conclusion This study suggests that there are continuing issues in the production techniques utilised between dentists and dental laboratories

    Angular and Current-target Correlations in Deep Inelastic Scattering at HERA

    Get PDF
    Correlations between charged particles in deep inelastic e+ p scattering have been studied in the Breit frame with the ZEUS detector at HERA using an integrated luminosity of 6.4pb-1. Short-range correlations are analysed in terms of the angular separation between current-region particles within a cone centred around the virtual photon axis. Long-range correlations between the current and target regions have also been measured. The data support predictions for the scaling behaviour of the angular correlations at high Q2 and for anti-correlations between the current and target regions over a large range in Q2 and in the Bjorken scaling variable x. Analytic QCD calculations and Monte Carlo models correctly describe the trends of the data at high Q2, but show quantitative discrepancies. The data show differences between the correlations in deep inelastic scattering and e+e- annihilation

    First measurement of coherent ρ0 photoproduction in ultra-peripheral Xe–Xe collisions at √sNN = 5.44 TeV

    Get PDF
    The first measurement of the coherent photoproduction of ρ0 vector mesons in ultra-peripheral Xe–Xe collisions at sNN=5.44 TeV is presented. This result, together with previous HERA Îłp data and γ–Pb measurements from ALICE, describes the atomic number (A) dependence of this process, which is particularly sensitive to nuclear shadowing effects and to the approach to the black-disc limit of QCD at a semi-hard scale. The cross section of the Xe+Xe→ρ0+Xe+Xe process, measured at midrapidity through the decay channel ρ0→π+π−, is found to be dσ/dy=131.5±5.6(stat.)−16.9+17.5(syst.) mb. The ratio of the continuum to resonant contributions for the production of pion pairs is also measured. In addition, the fraction of events accompanied by electromagnetic dissociation of either one or both colliding nuclei is reported. The dependence on A of cross section for the coherent ρ0 photoproduction at a centre-of-mass energy per nucleon of the ÎłA system of WÎłA,n=65 GeV is found to be consistent with a power-law behaviour σ(ÎłA→ρ0A)∝Aα with a slope α=0.96±0.02(syst.). This slope signals important shadowing effects, but it is still far from the behaviour expected in the black-disc limit.publishedVersio
    • 

    corecore