1,182 research outputs found

    Do Staphylococcus epidermidis genetic clusters predict isolation sources?

    Get PDF
    Staphylococcus epidermidis is a ubiquitous colonizer of human skin and a common cause of medical device-associated infections. The extent to which the population genetic structure of S. epidermidis distinguishes commensal from pathogenic isolates is unclear. Previously, Bayesian clustering of 437 multilocus sequence types (STs) in the international database revealed a population structure of six genetic clusters (GCs) that may reflect the species' ecology. Here, we first verified the presence of six GCs, including two (GC3 and GC5) with significant admixture, in an updated database of 578 STs. Next, a single nucleotide polymorphism (SNP) assay was developed that accurately assigned 545 (94%) of 578 STs to GCs. Finally, the hypothesis that GCs could distinguish isolation sources was tested by SNP typing and GC assignment of 154 isolates from hospital patients with bacteremia and those with blood culture contaminants and from nonhospital carriage. GC5 was isolated almost exclusively from hospital sources. GC1 and GC6 were isolated from all sources but were overrepresented in isolates from nonhospital and infection sources, respectively. GC2, GC3, and GC4 were relatively rare in this collection. No association was detected between fdh-positive isolates (GC2 and GC4) and nonhospital sources. Using a machine learning algorithm, GCs predicted hospital and nonhospital sources with 80% accuracy and predicted infection and contaminant sources with 45% accuracy, which was comparable to the results seen with a combination of five genetic markers (icaA, IS256, sesD [bhp], mecA, and arginine catabolic mobile element [ACME]). Thus, analysis of population structure with subgenomic data shows the distinction of hospital and nonhospital sources and the near-inseparability of sources within a hospital

    Unravelling the effects of age, period and cohort on metabolic syndrome components in a Taiwanese population using partial least squares regression

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We investigate whether the changing environment caused by rapid economic growth yielded differential effects for successive Taiwanese generations on 8 components of metabolic syndrome (MetS): body mass index (BMI), systolic blood pressure (SBP), diastolic blood pressure (DBP), fasting plasma glucose (FPG), triglycerides (TG), high-density lipoprotein (HDL), Low-density lipoproteins (LDL) and uric acid (UA).</p> <p>Methods</p> <p>To assess the impact of age, birth year and year of examination on MetS components, we used partial least squares regression to analyze data collected by Mei-Jaw clinics in Taiwan in years 1996 and 2006. Confounders, such as the number of years in formal education, alcohol intake, smoking history status, and betel-nut chewing were adjusted for.</p> <p>Results</p> <p>As the age of individuals increased, the values of components generally increased except for UA. Men born after 1970 had lower FPG, lower BMI, lower DBP, lower TG, Lower LDL and greater HDL; women born after 1970 had lower BMI, lower DBP, lower TG, Lower LDL and greater HDL and UA. There is a similar pattern between the trend in levels of metabolic syndrome components against birth year of birth and economic growth in Taiwan.</p> <p>Conclusions</p> <p>We found cohort effects in some MetS components, suggesting associations between the changing environment and health outcomes in later life. This ecological association is worthy of further investigation.</p

    Effective Theory Approach to the Spontaneous Breakdown of Lorentz Invariance

    Get PDF
    We generalize the coset construction of Callan, Coleman, Wess and Zumino to theories in which the Lorentz group is spontaneously broken down to one of its subgroups. This allows us to write down the most general low-energy effective Lagrangian in which Lorentz invariance is non-linearly realized, and to explore the consequences of broken Lorentz symmetry without having to make any assumptions about the mechanism that triggers the breaking. We carry out the construction both in flat space, in which the Lorentz group is a global spacetime symmetry, and in a generally covariant theory, in which the Lorentz group can be treated as a local internal symmetry. As an illustration of this formalism, we construct the most general effective field theory in which the rotation group remains unbroken, and show that the latter is just the Einstein-aether theory.Comment: 45 pages, no figures

    Genetic predictors of cardiovascular morbidity in Bardet-Biedl syndrome

    Get PDF
    Bardet-Biedl syndrome is a rare ciliopathy characterized by retinal dystrophy, obesity, intellectual disability, polydactyly, hypogonadism and renal impairment. Patients are at high risk of cardiovascular disease. Mutations in BBS1 and BBS10 account for more than half of those with molecular confirmation of the diagnosis. To elucidate genotype-phenotype correlations with respect to cardiovascular risk indicators 50 patients with mutations in BBS1 were compared with 19 patients harbouring BBS10 mutations. All patients had truncating, missense or compound missense/truncating mutations. The effect of genotype and mutation type was analysed. C-reactive protein was higher in those with mutations in BBS10 and homozygous truncating mutations (p = 0.013 and p = 0.002, respectively). Patients with mutations in BBS10 had higher levels of C peptide than those with mutations in BBS1 (p = 0.043). Triglyceride levels were significantly elevated in patients with homozygous truncating mutations (p = 0.048). Gamma glutamyl transferase was higher in patients with homozygous truncating mutations (p = 0.007) and heterozygous missense and truncating mutations (p = 0.002) than those with homozygous missense mutations. The results are compared with clinical cardiovascular risk factors. Patients with missense mutations in BBS1 have lower biochemical cardiovascular disease markers compared with patients with BBS10 and other BBS1 mutations. This could contribute to stratification of the clinical service

    Short-term efficacy of physical interventions in osteoarthritic knee pain. A systematic review and meta-analysis of randomised placebo-controlled trials.

    Get PDF
    BACKGROUND: Treatment efficacy of physical agents in osteoarthritis of the knee (OAK) pain has been largely unknown, and this systematic review was aimed at assessing their short-term efficacies for pain relief. METHODS: Systematic review with meta-analysis of efficacy within 1-4 weeks and at follow up at 1-12 weeks after the end of treatment. RESULTS: 36 randomised placebo-controlled trials (RCTs) were identified with 2434 patients where 1391 patients received active treatment. 33 trials satisfied three or more out of five methodological criteria (Jadad scale). The patient sample had a mean age of 65.1 years and mean baseline pain of 62.9 mm on a 100 mm visual analogue scale (VAS). Within 4 weeks of the commencement of treatment manual acupuncture, static magnets and ultrasound therapies did not offer statistically significant short-term pain relief over placebo. Pulsed electromagnetic fields offered a small reduction in pain of 6.9 mm [95% CI: 2.2 to 11.6] (n = 487). Transcutaneous electrical nerve stimulation (TENS, including interferential currents), electro-acupuncture (EA) and low level laser therapy (LLLT) offered clinically relevant pain relieving effects of 18.8 mm [95% CI: 9.6 to 28.1] (n = 414), 21.9 mm [95% CI: 17.3 to 26.5] (n = 73) and 17.7 mm [95% CI: 8.1 to 27.3] (n = 343) on VAS respectively versus placebo control. In a subgroup analysis of trials with assumed optimal doses, short-term efficacy increased to 22.2 mm [95% CI: 18.1 to 26.3] for TENS, and 24.2 mm [95% CI: 17.3 to 31.3] for LLLT on VAS. Follow-up data up to 12 weeks were sparse, but positive effects seemed to persist for at least 4 weeks after the course of LLLT, EA and TENS treatment was stopped. CONCLUSION: TENS, EA and LLLT administered with optimal doses in an intensive 2-4 week treatment regimen, seem to offer clinically relevant short-term pain relief for OAK

    Geochemical detection of carbon dioxide in dilute aquifers

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Carbon storage in deep saline reservoirs has the potential to lower the amount of CO<sub>2 </sub>emitted to the atmosphere and to mitigate global warming. Leakage back to the atmosphere through abandoned wells and along faults would reduce the efficiency of carbon storage, possibly leading to health and ecological hazards at the ground surface, and possibly impacting water quality of near-surface dilute aquifers. We use static equilibrium and reactive transport simulations to test the hypothesis that perturbations in water chemistry associated with a CO<sub>2 </sub>gas leak into dilute groundwater are important measures for the potential release of CO<sub>2 </sub>to the atmosphere. Simulation parameters are constrained by groundwater chemistry, flow, and lithology from the High Plains aquifer. The High Plains aquifer is used to represent a typical sedimentary aquifer overlying a deep CO<sub>2 </sub>storage reservoir. Specifically, we address the relationships between CO<sub>2 </sub>flux, groundwater flow, detection time and distance. The CO<sub>2 </sub>flux ranges from 10<sup>3 </sup>to 2 × 10<sup>6 </sup>t/yr (0.63 to 1250 t/m<sup>2</sup>/yr) to assess chemical perturbations resulting from relatively small leaks that may compromise long-term storage, water quality, and surface ecology, and larger leaks characteristic of short-term well failure.</p> <p>Results</p> <p>For the scenarios we studied, our simulations show pH and carbonate chemistry are good indicators for leakage of stored CO<sub>2 </sub>into an overlying aquifer because elevated CO<sub>2 </sub>yields a more acid pH than the ambient groundwater. CO<sub>2 </sub>leakage into a dilute groundwater creates a slightly acid plume that can be detected at some distance from the leak source due to groundwater flow and CO<sub>2 </sub>buoyancy. pH breakthrough curves demonstrate that CO<sub>2 </sub>leaks can be easily detected for CO<sub>2 </sub>flux ≥ 10<sup>4 </sup>t/yr within a 15-month time period at a monitoring well screened within a permeable layer 500 m downstream from the vertical gas trace. At lower flux rates, the CO<sub>2 </sub>dissolves in the aqueous phase in the lower most permeable unit and does not reach the monitoring well. Sustained pumping in a developed aquifer mixes the CO<sub>2</sub>-affected water with the ambient water and enhances pH signal for small leaks (10<sup>3 </sup>t/yr) and reduces pH signal for larger leaks (≥ 10<sup>4</sup>t/yr).</p> <p>Conclusion</p> <p>The ability to detect CO<sub>2 </sub>leakage from a storage reservoir to overlying dilute groundwater is dependent on CO<sub>2 </sub>solubility, leak flux, CO<sub>2 </sub>buoyancy, and groundwater flow. Our simulations show that the most likely places to detect CO<sub>2 </sub>are at the base of the confining layer near the water table where CO<sub>2 </sub>gas accumulates and is transported laterally in all directions, and downstream of the vertical gas trace where groundwater flow is great enough to transport dissolved CO<sub>2 </sub>laterally. Our simulations show that CO<sub>2 </sub>may not rise high enough in the aquifer to be detected because aqueous solubility and lateral groundwater transport within the lower aquifer unit exceeds gas pressure build-up and buoyancy needed to drive the CO<sub>2 </sub>gas upwards.</p

    Primary Hyperparathyroidism Patients with Positive Preoperative Sestamibi Scan and Negative Ultrasound Are More Likely to Have Posteriorly Located Upper Gland Adenomas (PLUGs)

    Get PDF
    BackgroundStandard preoperative imaging for primary hyperparathyroidism usually includes sestamibi scanning (MIBI) and ultrasound (US). In a subset of patients with a positive MIBI and a negative US, we hypothesize that the parathyroid adenomas are more likely to be located posteriorly in the neck, where anatomically they are more difficult to detect by US.MethodsWe retrospectively reviewed the records of 661 patients treated for primary hyperparathyroidism between 2004 and 2009 at a tertiary referral center. We included patients who for their first operation had a MIBI that localized a single lesion in the neck and an US that found no parathyroid adenoma. We excluded patients with persistent or recurrent hyperparathyroidism, and patients with MIBIs that were negative, that had more than one positive focus, or that had foci outside of the neck. Sixty-six cases were included in the final analysis.ResultsA total of 54 patients (83%) had a single adenoma, 4 (6%) had double adenomas, and 7 (11%) had hyperplasia. Thirty-three patients (51%) had a single upper gland adenoma; 19 of these (58%) were posteriorly located upper gland adenomas (PLUGs). PLUGs occurred more often on the right side than on the left (P = 0.048, Fisher's test). PLUGs were also larger than other single adenomas (mean 1.85 vs. 1.48&nbsp;cm, P = 0.021, t-test). Seventy-six percent of patients successfully underwent a unilateral or focused exploration. Six patients (9%) had persistent disease, which is double our group's overall average (4-5%).ConclusionsPrimary hyperparathyroid patients with preoperative positive MIBI and negative US are more likely to have PLUGs

    The Endocrine and Metabolic Characteristics of a Large Bardet-Biedl Syndrome Clinic Population

    Get PDF
    Context: Bardet-Biedl syndrome (BBS) is a rare autosomal recessive disorder in which previous reports have described obesity and a metabolic syndrome. Objective: We describe the endocrine and metabolic characteristics of a large BBS population compared with matched control subjects. Design: We performed a case-control study. Setting: This study was performed at a hospital clinic. Patients: Study patients had a clinical or genetic diagnosis of BBS. Main Outcome Measurements: Our study determined the prevalence of a metabolic syndrome in our cohort. Results: A total of 152 subjects were studied. Eighty-four (55.3%) were male. Mean (± standard deviation) age was 33.2 ± 1.0 years. Compared with age-, sex-, and body mass index-matched control subjects, fasting glucose and insulin levels were significantly higher in subjects with BBS (glucose: BBS, 5.2 ± 1.2 mmol/L vs control, 4.9 ± 0.9 mmol/L, P = 0.04; insulin: BBS, 24.2 ± 17.0 pmol/L vs control, 14.2 ± 14.8 pmol/L, P < 0.001). Serum triglycerides were significantly higher in subjects with BBS (2.0 ± 1.2 mmol/L) compared with control subjects (1.3 ± 0.8 mmol/L; P < 0.001), but total cholesterol, high-density lipoprotein, and low-density lipoprotein were similar in both groups. Systolic blood pressure was higher in the BBS group (BBS, 135 ± 18 mm Hg vs control subjects, 129 ± 16 mm Hg; P = 0.02). Alanine transaminase was raised in 34 (26.8%) subjects with BBS, compared with five (8.9%) control subjects (P = 0.01). The rate of metabolic syndrome, determined using International Diabetes Federation criteria, was significantly higher in the BBS group (54.3%) compared with control subjects (26% P < 0.001). Twenty-six (19.5%) of male subjects with BBS were hypogonadal (serum testosterone, 9.9 ± 5.3 mmol/L), but significant pituitary abnormalities were uncommon. Subclinical hypothyroidism was present in 24 of 125 (19.4%) patients with BBS, compared with 3 of 65 (4.6%) control subjects (P = 0.01). Conclusions: Insulin resistance and the metabolic syndrome are increased in adult patients with BBS compared with matched control subjects. Increased subclinical hypothyroidism in the BBS cohort needs further investigation

    The Random Nature of Genome Architecture: Predicting Open Reading Frame Distributions

    Get PDF
    Background: A better understanding of the size and abundance of open reading frames (ORFS) in whole genomes may shed light on the factors that control genome complexity. Here we examine the statistical distributions of open reading frames (i.e. distribution of start and stop codons) in the fully sequenced genomes of 297 prokaryotes, and 14 eukaryotes. Methodology/Principal Findings: By fitting mixture models to data from whole genome sequences we show that the size-frequency distributions for ORFS are strikingly similar across prokaryotic and eukaryotic genomes. Moreover, we show that i) a large fraction (60–80%) of ORF size-frequency distributions can be predicted a priori with a stochastic assembly model based on GC content, and that (ii) size-frequency distributions of the remaining “non-random” ORFs are well-fitted by log-normal or gamma distributions, and similar to the size distributions of annotated proteins. Conclusions/Significance: Our findings suggest stochastic processes have played a primary role in the evolution of genome complexity, and that common processes govern the conservation and loss of functional genomics units in both prokaryotes and eukaryotes.8 page(s
    corecore