1,807 research outputs found

    Orchestrating Tuple-based Languages

    Get PDF
    The World Wide Web can be thought of as a global computing architecture supporting the deployment of distributed networked applications. Currently, such applications can be programmed by resorting mainly to two distinct paradigms: one devised for orchestrating distributed services, and the other designed for coordinating distributed (possibly mobile) agents. In this paper, the issue of designing a pro- gramming language aiming at reconciling orchestration and coordination is investigated. Taking as starting point the orchestration calculus Orc and the tuple-based coordination language Klaim, a new formalism is introduced combining concepts and primitives of the original calculi. To demonstrate feasibility and effectiveness of the proposed approach, a prototype implementation of the new formalism is described and it is then used to tackle a case study dealing with a simplified but realistic electronic marketplace, where a number of on-line stores allow client applications to access information about their goods and to place orders

    Network-aware Evaluation Environment for Reputation Systems

    Get PDF
    Parties of reputation systems rate each other and use ratings to compute reputation scores that drive their interactions. When deciding which reputation model to deploy in a network environment, it is important to find the most suitable model and to determine its right initial configuration. This calls for an engineering approach for describing, implementing and evaluating reputation systems while taking into account specific aspects of both the reputation systems and the networked environment where they will run. We present a software tool (NEVER) for network-aware evaluation of reputation systems and their rapid prototyping through experiments performed according to user-specified parameters. To demonstrate effectiveness of NEVER, we analyse reputation models based on the beta distribution and the maximum likelihood estimation

    Evidence of spontaneous spin polarized transport in magnetic nanowires

    Full text link
    The exploitation of the spin in charge-based systems is opening revolutionary opportunities for device architecture. Surprisingly, room temperature electrical transport through magnetic nanowires is still an unresolved issue. Here, we show that ferromagnetic (Co) suspended atom chains spontaneously display an electron transport of half a conductance quantum, as expected for a fully polarized conduction channel. Similar behavior has been observed for Pd (a quasi-magnetic 4d metal) and Pt (a non-magnetic 5d metal). These results suggest that the nanowire low dimensionality reinforces or induces magnetic behavior, lifting off spin degeneracy even at room temperature and zero external magnetic field.Comment: 4 pages, 3 eps fig

    Vertical ridge augmentation with Ti-reinforced dense polytetrafluoroethylene (d-PTFE) membranes or Ti-meshes and collagen membranes: 3-year results of a randomized clinical trial

    Get PDF
    BackgroundThe present study aimed to evaluate hard and soft tissue parameters around implants placed in augmented posterior mandible, comparing Ti-reinforced d-PTFE membranes with Ti-meshes covered with collagen membranes, after 3 years of follow-up. Materials and MethodsForty eligible patients were randomly assigned to group A (Ti-reinforced d-PTFE membrane) or group B (mesh covered with collagen membrane) for vertical ridge augmentation (VRA) and simultaneous implants. Implants were evaluated using specific peri-implant parameters for bone and soft tissues: probing pocket depth (PPD), modified plaque index (mPI), bleeding on probing (BoP), modified gingival index (mGI), thickness of keratinized tissue (tKT), width of keratinized tissue (wKT), fornix depth (FD), peri-implant bone level (PBL), interproximal bone peaks (IBP), marginal bone loss (MBL), interproximal bone loss (IBL). ResultsA total of 28 patients with 79 implants were evaluated after 3 years of follow-up. The mean value of MBL was 0.70 mm (group A = 0.73 mm; group B = 0.71 mm), while mean IBL was 0.54 mm (group A = 0.64 mm; group B = 0.40 mm). The treatment with meshes resulted not inferior to PTFE and their clinical results appeared similar. A strong correlation between PBL and IBP was confirmed. Both study groups showed an increase of tKT and wKT values. ConclusionIn the posterior mandible, VRA using both techniques provides stable PBLs up to 3 years. A correct soft tissue management and a strict professional oral hygiene protocol play a crucial role on peri-implant health over time

    Fundamental Power Limits of SAR and ΔΣ Analog-to-Digital Converters

    Get PDF
    This work aims at estimating and comparing the power limits of ΔΣ and charge-redistribution successiveapproximation register (CR-SAR) analog-to-digital converters (ADCs), in order to identify which topology is the most powerefficient for a target resolution. A power consumption model for mismatch-limited SAR ADCs and for discrete-time (DT) ΔΣ modulators is presented and validated against experimental data. SAR ADCs are found to be the best choice for low-to-medium resolutions, up to roughly 80 dB of dynamic range (DR). At high resolutions, on the other hand, ΔΣ modulators become more power-efficient. This is due to the intrinsic robustness of the ΔΣ modulation principle against circuit imperfections and nonidealities. Furthermore, a comparison of the area occupation of such topologies reveals that, at high resolutions and for a given dynamic range, ΔΣ ADCs result more area-efficient as well

    Ultrasonographic honeycomb pattern of the spleen in cats: correlation with pathological diagnosis in 33 cases

    Get PDF
    Objectives: The aim of this study was to evaluate the relationship between the ultra sonographic (US) diffuse honeycomb pattern (HCP) of the spleen and a pathological diagnosis in cats, and to assess the influence of transducer type on HCP visualisation. Methods: Abdominal ultrasounds of cats with an HCP were reviewed and splenic size, shape, margination, other parenchymal alterations and splenic hilar lymphadenopathy were recorded. When applicable, images acquired with high-frequency linear and curvilinear transducers were compared to determine if an HCP was more frequently demonstrated on high-resolution images. A retrospective review of the corresponding splenic cyto histopathological samples was also performed. Results: Thirty-three cats met the inclusion criteria. Five cases were diagnosed by histology and 28 by cytology, confirmed by PCR for antigen receptor rearrangements (PARR) in uncertain cases. There were 15 cases of lymphoid hyperplasia, eight cases of lymphoma (four B cell, three T cell and one large granular lymphocytes), six cats with splenitis, three with extramedullary haematopoiesis and one with histiocytic sarcoma. The prevalence of lymphoma in cats with an HCP of the spleen was 24%. Splenomegaly was the most frequent US feature associated with an HCP and was observed in all lymphoma cases. In the images obtained from both high-frequency linear and micro-convex transducers the visualisation of an HCP was enabled in all cases (24/24) and in 62.5% (15/24), respectively. Conclusions and relevance: Based on our findings, an US HCP of the spleen in cats can be associated with benign and malignant disorders and is infrequently associated with lymphoma in comparison with dogs. Cytological or histological examination, possibly supplemented by PARR, should always be performed for diagnostic support. Use of high-frequency linear transducers is recommended to properly recognise an HCP or subtle changes in splenic parenchyma
    • 

    corecore