185 research outputs found

    Reference values and clinical predictors of bone strength for HR-pQCT-based distal radius and tibia strength assessments in women and men.

    Get PDF
    Reference values for radius and tibia strength using multiple-stack high-resolution peripheral quantitative computed tomography (HR-pQCT) with homogenized finite element analysis are presented in order to derive critical values improving risk prediction models of osteoporosis. Gender and femoral neck areal bone mineral density (aBMD) were independent predictors of bone strength. INTRODUCTION The purpose was to obtain reference values for radius and tibia bone strength computed by using the homogenized finite element analysis (hFE) using multiple stacks with a HR-pQCT. METHODS Male and female healthy participants aged 20-39 years were recruited at the University Hospital of Bern. They underwent interview and clinical examination including hand grip, gait speed and DXA of the hip. The nondominant forearm and tibia were scanned with a double and a triple-stack protocol, respectively, using HR-pQCT (XCT II, SCANCO Medical AG). Bone strength was estimated by using the hFE analysis, and reference values were calculated using quantile regression. Multivariable analyses were performed to identify clinical predictors of bone strength. RESULTS Overall, 46 women and 41 men were recruited with mean ages of 25.1 (sd 5.0) and 26.2 (sd 5.2) years. Sex-specific reference values for bone strength were established. Men had significantly higher strength for radius (mean (sd) 6640 (1800) N vs. 4110 (1200) N; p < 0.001) and tibia (18,200 (4220) N vs. 11,970 (3150) N; p < 0.001) than women. In the two multivariable regression models with and without total hip aBMD, the addition of neck hip aBMD significantly improved the model (p < 0.001). No clinical predictors of bone strength other than gender and aBMD were identified. CONCLUSION Reference values for radius and tibia strength using multiple HR-pQCT stacks with hFE analysis are presented and provide the basis to help refining accurate risk prediction models. Femoral neck aBMD and gender were significant predictors of bone strength

    Light-coupled cryogenic probes to detect low-micromolar samples and allow for an automated NMR platform

    Get PDF
    Recent advances in NMR fragment screening use sample illumination to boost NMR sensitivity, reduce measurement time to a few seconds, and reduce sample concentration to a few micromolars. Nevertheless, the absence of a fully automated solution to measure several hundreds of samples with photoinduced hyperpolarization limits the large-scale applicability of the method. We present a setup to couple an optical fiber with a cryogenic probe using the flow-cell accessory port. This setup is compatible with commercially available autosamplers, enabling the fully automated measurement of several hundreds of samples per day.</p

    Effect of biomechanical footwear on knee pain in people with knee osteoarthritis : the BIOTOK randomized clinical trial

    Get PDF
    Importance: Individually calibrated biomechanical footwear therapy may improve pain and physical function in people with symptomatic knee osteoarthritis, but the benefits of this therapy are unclear. Objective: To assess the effect of a biomechanical footwear therapy vs control footwear over 24 weeks of follow-up. Design, Setting, and Participants: Randomized clinical trial conducted at a Swiss university hospital. Participants (N = 220) with symptomatic, radiologically confirmed knee osteoarthritis were recruited between April 20, 2015, and January 10, 2017. The last participant visit occurred on August 15, 2017. Interventions: Participants were randomized to biomechanical footwear involving shoes with individually adjustable external convex pods attached to the outsole (n = 111) or to control footwear (n = 109) that had visible outsole pods that were not adjustable and did not create a convex walking surface. Main Outcomes and Measures: The primary outcome was knee pain at 24 weeks of follow-up assessed with the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain subscore standardized to range from 0 (no symptoms) to 10 (extreme symptoms). The secondary outcomes included WOMAC physical function and stiffness subscores and the WOMAC global score, all ranging from 0 (no symptoms) to 10 (extreme symptoms) at 24 weeks of follow-up, and serious adverse events. Results: Among the 220 randomized participants (mean age, 65.2 years [SD, 9.3 years]; 104 women [47.3%]), 219 received the allocated treatment and 213 (96.8%) completed follow-up. At 24 weeks of follow-up, the mean standardized WOMAC pain subscore improved from 4.3 to 1.3 in the biomechanical footwear group and from 4.0 to 2.6 in the control footwear group (between-group difference in scores at 24 weeks of follow-up, -1.3 [95% CI, -1.8 to -0.9]; P < .001). The results were consistent for WOMAC physical function subscore (between-group difference, -1.1 [95% CI, -1.5 to -0.7]), WOMAC stiffness subscore (between-group difference, -1.4 [95% CI, -1.9 to -0.9]), and WOMAC global score (between-group difference, -1.2 [95% CI, -1.6 to -0.8]) at 24 weeks of follow-up. Three serious adverse events occurred in the biomechanical footwear group compared with 9 in the control footwear group (2.7% vs 8.3%, respectively); none were related to treatment. Conclusions and Relevance: Among participants with knee pain from osteoarthritis, use of biomechanical footwear compared with control footwear resulted in an improvement in pain at 24 weeks of follow-up that was statistically significant but of uncertain clinical importance. Further research would be needed to assess long-term efficacy and safety, as well as replication, before reaching conclusions about the clinical value of this device

    Solar Particle Radiation Storms Forecasting and Analysis: The HESPERIA HORIZON 2020 Project and Beyond

    Get PDF
    While it is believed that the acceleration of Solar Energetic Particles (SEPs) is powered by the release of magnetic energy at the Sun, the nature, and location of the acceleration are uncertain, i.e. the origin of the highest energy particles is heavily debated. Information about the highest energy SEPs relies on observations by ground-based Neutron Monitors (NMs). SEPs with energies above 500 MeV entering the Earth’s atmosphere will lead to an increase of the intensities recorded by NMs on the ground, also known as Ground Level Event or Ground Level Enhancement (GLE). A Fokker-Planck equation well describes the interplanetary transport of near relativistic electrons and protons. An NM is an integral counter defined by its yield function. From the observations of the NM network, the additional solar cosmic ray characteristics (intensity, spectrum, and anisotropy) in the energy range ≳ ≳ 500 MeV can be assessed. If the interplanetary magnetic field outside the Earth magnetosphere is known (see Sect. 10.3.2) a computation chain can be set up in order to calculate the count rate increase of an NM for a delta injection at the Sun along the magnetic field line that connects the Sun with the Earth (Sect. 10.3.3). By this computations, we define a set of Green’s functions that can be fitted to an observed GLE to determine the injection time profile. If the latter is compared to remote sensing measurements like radio observations conclusions of the most probable acceleration process can be drawn.</p

    Major Surface Glycoproteins of Insect Forms of Trypanosoma brucei Are Not Essential for Cyclical Transmission by Tsetse

    Get PDF
    Procyclic forms of Trypanosoma brucei reside in the midgut of tsetse flies where they are covered by several million copies of glycosylphosphatidylinositol-anchored proteins known as procyclins. It has been proposed that procyclins protect parasites against proteases and/or participate in tropism, directing them from the midgut to the salivary glands. There are four different procyclin genes, each subject to elaborate levels of regulation. To determine if procyclins are essential for survival and transmission of T. brucei, all four genes were deleted and parasite fitness was compared in vitro and in vivo. When co-cultured in vitro, the null mutant and wild type trypanosomes (tagged with cyan fluorescent protein) maintained a near-constant equilibrium. In contrast, when flies were infected with the same mixture, the null mutant was rapidly overgrown in the midgut, reflecting a reduction in fitness in vivo. Although the null mutant is patently defective in competition with procyclin-positive parasites, on its own it can complete the life cycle and generate infectious metacyclic forms. The procyclic form of T. brucei thus differs strikingly from the bloodstream form, which does not tolerate any perturbation of its variant surface glycoprotein coat, and from other parasites such as Plasmodium berghei, which requires the circumsporozoite protein for successful transmission to a new host

    Comparison of codes assessing galactic cosmic radiation exposure of aircraft crew

    Get PDF
    The assessment of the exposure to cosmic radiation onboard aircraft is one of the preoccupations of bodies responsible for radiation protection. Cosmic particle flux is significantly higher onboard aircraft than at ground level and its intensity depends on the solar activity. The dose is usually estimated using codes validated by the experimental data. In this paper, a comparison of various codes is presented, some of them are used routinely, to assess the dose received by the aircraft crew caused by the galactic cosmic radiation. Results are provided for periods close to solar maximum and minimum and for selected flights covering major commercial routes in the world. The overall agreement between the codes, particularly for those routinely used for aircraft crew dosimetry, was better than ±20 % from the median in all but two cases. The agreement within the codes is considered to be fully satisfactory for radiation protection purpose

    Search for Event Rate Modulation in XENON100 Electronic Recoil Data

    Get PDF
    We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to identify any periodicity up to 500 days. We find a global significance of less than 1 sigma for all periods suggesting no statistically significant modulation in the data. While the local significance for an annual modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and the phase of the modulation disfavor a dark matter interpretation. The DAMA/LIBRA annual modulation interpreted as a dark matter signature with axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.Comment: 6 pages, 4 figure

    Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

    Get PDF
    The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 216 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.Comment: 10 pages, 5 figure

    Search for Two-Neutrino Double Electron Capture of 124^{124}Xe with XENON100

    Get PDF
    Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For 124^{124}Xe this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K-shell of 124^{124}Xe using 7636 kg⋅\cdotd of data from the XENON100 dark matter detector. Using a Bayesian analysis we observed no significant excess above background, leading to a lower 90 % credibility limit on the half-life T1/2>6.5×1020T_{1/2}>6.5\times10^{20} yr. We also evaluated the sensitivity of the XENON1T experiment, which is currently being commissioned, and find a sensitivity of T1/2>6.1×1022T_{1/2}>6.1\times10^{22} yr after an exposure of 2 t⋅\cdotyr.Comment: 6 pages, 4 figure

    Removing krypton from xenon by cryogenic distillation to the ppq level

    Get PDF
    The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the β\beta-emitter 85^{85}Kr which is an intrinsic contamination of the xenon. For the XENON1T experiment a concentration of natural krypton in xenon nat\rm{^{nat}}Kr/Xe < 200 ppq (parts per quadrillion, 1 ppq = 10−15^{-15} mol/mol) is required. In this work, the design of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4⋅\cdot105^5 with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of nat\rm{^{nat}}Kr/Xe < 26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN
    • …
    corecore