113 research outputs found

    Preferential oxidation of CO over Au/CuOx-CeO2 catalyst in microstructured reactors studied through CFD simulations

    Get PDF
    A computational fluid dynamics (CFD) simulation study of the preferential oxidation of CO (CO-PROX) in microstructured reactors consisting in square and semicircular microchannels coated with anAu/CuOx¿CeO2catalyst is presented. The CO content of the feed stream was set at 1 vol.%. A parametricsensitivity analysis has been performed under isothermal conditions revealing that an optimal reactiontemperature exists that leads to a minimum CO content at the microreactor exit. The influence of thespace velocity, CO2concentration and oxygen-to-CO molar ratio in the feed stream (), catalyst loading,and microchannel characteristic dimension (d) on the microreactor performance has been investigated.Under suitable conditions, the CO concentration can be reduced below 10 ppm at relatively low tem-peratures within the 155¿175¿C range. A negative effect of the increase of d from 0.35 mm to 2.8 mmon the CO removal efficiency has been found and attributed to a more detrimental effect of the masstransport limitations on the oxidation of CO than that of H2. Non-isothermal CFD simulations have beenperformed to investigate the cooling of the CO-PROX reactor with air or a fuel cell anode off gas surrogatein parallel microchannels. Due to the very rapid heat transfer allowed by the microreactor and the stronginfluence of the reaction temperature on the exit CO concentration, a careful control of the coolant flowrate and inlet temperature is required for proper reactor operation. The microreactor behavior is virtuallyisothermal.Peer Reviewe

    Influence of left bundle branch block on the electrocardiographic changes induced by acute coronary artery occlusion of distinct location and duration

    Get PDF
    Altres ajuts: This work was supported by Spanish Ministerio de Economia y Competitividad, Instituto de Salud Carlos III, Centro de Investigación Biomédica en Red Enfermedades Cardiovaculares, CIBERCV (CB16/11/00276), and Fondo Europeo de Desarrollo Regional (FEDER).Background: Electrocardiographic (ECG) diagnosis of acute myocardial ischemia is hampered in the presence of left bundle branch block (LBBB). Objectives: We analyzed the influence of location and duration of myocardial ischemia on the ECG changes in pigs with LBBB. Methods: LBBB was acutely induced in 14 closed chest anesthetized pigs by local electrical ablation. Thereafter, episodes of 5 min catheter balloon occlusion followed by 10 min reperfusion of the left anterior descending (LAD), left circumflex (LCX), and right (RCA) coronary arteries were done sequentially in 5 pigs. Additionally, a 3-h occlusion of these arteries was performed separately in the other 9 pigs. A 15-lead ECG including leads V7 to V9 was continuously recorded. Results: Ablation induced LBBB showed QRS widening, loss of r wave in V1, and predominant R waves in V2 to V9. After 5 min of ischemia the occluded artery could be identified in all cases: the LAD by R waves and ST elevation in V1-V3; the LCX by both ST segment elevation in II, III, aVF, V7 to V9 and ST segment depression in V1 to V4; and the RCA by ST depression and new S-waves in all precordial leads. Three hours after coronary occlusion, ST segment changes declined progressively and only the LAD occlusion could be reliably recognized. Conclusion: LBBB did not mask the ECG recognition of the occluded coronary artery during the first 60 min of ischemia, but 3 h later only the LAD occlusion could be reliably identified. ST elevation in leads V7 to V9 is specific of LCX occlusion and it could be useful in the diagnosis of acute myocardial ischemia in the presence of LBBB

    Preferential oxidation of CO (CO-PROX) over CuOx/CeO2 coated microchannel reactor

    Get PDF
    The general aspects of the synthesis and characterization results of a CuOx/CeO2 catalyst were presented. In addition the principal steps for manufacturing a microchannel reactor and for the coating of the CuOx/CeO2 catalyst onto the microchannels walls, were also summarized. The catalytic activity of this microchannel reactor during the preferential oxidation of CO (CO-PROX) was evaluated employing a feed-stream that simulates a reformate off-gas after the WGS unit. Two activation atmospheres were studied (H2/N2 and O2/N 2). The reducing pretreatment improved the resistance to deactivation by formation of carbonaceous species over the catalyst surface at high temperatures. The presence of H2O and CO2 in the feed-stream was also analyzed indicating that the adsorption of CO2 inhibited the conversion of CO at lower temperatures because these compounds modified the active sites through the formation of carbonaceous species on the catalyst surface. Finally, the experimental results of the microreactor performance were compared with CFD simulations that were carried out using a kinetic for the CuOx/CeO2 powder catalyst. The experimental results were reasonably well described by the model, thus confirming its validity.Peer Reviewe

    Influence of Left Bundle Branch Block on the Electrocardiographic Changes Induced by Acute Coronary Artery Occlusion of Distinct Location and Duration

    Get PDF
    Background: Electrocardiographic (ECG) diagnosis of acute myocardial ischemia is hampered in the presence of left bundle branch block (LBBB).Objectives: We analyzed the influence of location and duration of myocardial ischemia on the ECG changes in pigs with LBBB.Methods: LBBB was acutely induced in 14 closed chest anesthetized pigs by local electrical ablation. Thereafter, episodes of 5 min catheter balloon occlusion followed by 10 min reperfusion of the left anterior descending (LAD), left circumflex (LCX), and right (RCA) coronary arteries were done sequentially in 5 pigs. Additionally, a 3-h occlusion of these arteries was performed separately in the other 9 pigs. A 15-lead ECG including leads V7 to V9 was continuously recorded.Results: Ablation induced LBBB showed QRS widening, loss of r wave in V1, and predominant R waves in V2 to V9. After 5 min of ischemia the occluded artery could be identified in all cases: the LAD by R waves and ST elevation in V1–V3; the LCX by both ST segment elevation in II, III, aVF, V7 to V9 and ST segment depression in V1 to V4; and the RCA by ST depression and new S-waves in all precordial leads. Three hours after coronary occlusion, ST segment changes declined progressively and only the LAD occlusion could be reliably recognized.Conclusion: LBBB did not mask the ECG recognition of the occluded coronary artery during the first 60 min of ischemia, but 3 h later only the LAD occlusion could be reliably identified. ST elevation in leads V7 to V9 is specific of LCX occlusion and it could be useful in the diagnosis of acute myocardial ischemia in the presence of LBBB

    Prognostic Impact of Nutritional Status After Transcatheter Edge-to-Edge Mitral Valve Repair: The MIVNUT Registry

    Full text link
    Background Malnutrition is associated with poor prognosis in several cardiovascular diseases. However, its prognostic impact in patients undergoing transcatheter edge-to-edge mitral valve repair (TEER) is not well known. This study sought to assess the prevalence, clinical associations, and prognostic consequences of malnutrition in patients undergoing TEER. Methods and Results A total of 892 patients undergoing TEER from the international MIVNUT (Mitral Valve Repair and Nutritional Status) registry were studied. Malnutrition status was assessed with the Controlling Nutritional Status score. The association of nutritional status with mortality was analyzed with multivariable Cox regression models, whereas the association with heart failure admission was assessed by Fine-Gray models, with death as a competing risk. According to the Controlling Nutritional Status score, 74.4% of patients with TEER had any degree of malnutrition at the time of TEER (75.1% in patients with body mass index <25?kg/m2, 72.1% in those with body mass index ?25?kg/m2). However, only 20% had moderate-severe malnutrition. TEER was successful in most of patients (94.2%). During a median follow-up of 1.6?years (interquartile range, 0.6-3.0), 267 (29.9%) patients died and 256 patients (28.7%) were admitted for heart failure after TEER. Compared with normal nutritional status moderate-severe malnutrition resulted a strong predictor of mortality (adjusted hazard ratio [HR], 2.1 [95% CI, 1.1-2.4]; P<0.001) and heart failure admission (adjusted subdistribution HR, 1.6 [95% CI, 1.1-2.4]; P=0.015). Conclusions Malnutrition is common among patients submitted to TEER, and moderate-severe malnutrition is strongly associated with increased mortality and heart failure readmission. Assessment of nutritional status in these patients may help to improve risk stratification

    Management and outcomes of patients with left atrial appendage thrombus prior to percutaneous closure

    Get PDF
    Altres ajuts: Fundación Interhospitalaria para la Investigación Cardiovascular (FIC Foundation); Abbott.Objective: Left atrial appendage (LAA) thrombus has heretofore been considered a contraindication to percutaneous LAA closure (LAAC). Data regarding its management are very limited. The aim of this study was to analyse the medical and invasive treatment of patients referred for LAAC in the presence of LAA thrombus. Methods: This multicentre observational registry included 126 consecutive patients referred for LAAC with LAA thrombus on preprocedural imaging. Treatment strategies included intensification of antithrombotic therapy (IAT) or direct LAAC. The primary and secondary endpoints were a composite of bleeding, stroke and death at 18 months, and procedural success, respectively. Results: IAT was the preferred strategy in 57.9% of patients, with total thrombus resolution observed in 60.3% and 75.3% after initial and subsequent IAT, respectively. Bleeding complications and stroke during IAT occurred in 9.6% and 2.9%, respectively, compared with 3.8% bleeding and no embolic events in the direct LAAC group before the procedure. Procedural success was 90.5% (96.2% vs 86.3% in direct LAAC and IAT group, respectively, p=0.072), without cases of in-hospital thromboembolic complications. The primary endpoint occurred in 29.3% and device-related thrombosis was found in 12.8%, without significant difference according to treatment strategy. Bleeding complications at 18 months occurred in 22.5% vs 10.5% in the IAT and direct LAAC group, respectively (p=0.102). Conclusion: In the presence of LAA thrombus, IAT was the initial management strategy in half of our cohort, with initial thrombus resolution in 60% of these, but with a relatively high bleeding rate (∼10%). Direct LAAC was feasible, with high procedural success and absence of periprocedural embolic complications. However, a high rate of device-related thrombosis was detected during follow-up
    corecore