37 research outputs found

    Effect of sitagliptin on cardiovascular outcomes in type 2 diabetes

    Get PDF
    BACKGROUND: Data are lacking on the long-term effect on cardiovascular events of adding sitagliptin, a dipeptidyl peptidase 4 inhibitor, to usual care in patients with type 2 diabetes and cardiovascular disease. METHODS: In this randomized, double-blind study, we assigned 14,671 patients to add either sitagliptin or placebo to their existing therapy. Open-label use of antihyperglycemic therapy was encouraged as required, aimed at reaching individually appropriate glycemic targets in all patients. To determine whether sitagliptin was noninferior to placebo, we used a relative risk of 1.3 as the marginal upper boundary. The primary cardiovascular outcome was a composite of cardiovascular death, nonfatal myocardial infarction, nonfatal stroke, or hospitalization for unstable angina. RESULTS: During a median follow-up of 3.0 years, there was a small difference in glycated hemoglobin levels (least-squares mean difference for sitagliptin vs. placebo, -0.29 percentage points; 95% confidence interval [CI], -0.32 to -0.27). Overall, the primary outcome occurred in 839 patients in the sitagliptin group (11.4%; 4.06 per 100 person-years) and 851 patients in the placebo group (11.6%; 4.17 per 100 person-years). Sitagliptin was noninferior to placebo for the primary composite cardiovascular outcome (hazard ratio, 0.98; 95% CI, 0.88 to 1.09; P<0.001). Rates of hospitalization for heart failure did not differ between the two groups (hazard ratio, 1.00; 95% CI, 0.83 to 1.20; P = 0.98). There were no significant between-group differences in rates of acute pancreatitis (P = 0.07) or pancreatic cancer (P = 0.32). CONCLUSIONS: Among patients with type 2 diabetes and established cardiovascular disease, adding sitagliptin to usual care did not appear to increase the risk of major adverse cardiovascular events, hospitalization for heart failure, or other adverse events

    Measurements of W+W−+ ≥ 1 jet production cross-sections in pp collisions at s \sqrt{s} = 13 TeV with the ATLAS detector

    Get PDF
    Fiducial and differential cross-section measurements of W+W− production in association with at least one hadronic jet are presented. These measurements are sensitive to the properties of electroweak-boson self-interactions and provide a test of perturbative quantum chromodynamics and the electroweak theory. The analysis is performed using proton-proton collision data collected at p s = 13TeV with the ATLAS experiment, corresponding to an integrated luminosity of 139 fb−1. Events are selected with exactly one oppositely charged electron-muon pair and at least one hadronic jet with a transverse momentum of pT > 30 GeV and a pseudorapidity of |�| < 4.5. After subtracting the background contributions and correcting for detector effects, the jet-inclusive W+W−+ � 1 jet fiducial cross-section and W+W−+ jets differential cross-sections with respect to several kinematic variables are measured. These measurements include leptonic quantities, such as the lepton transverse momenta and the transverse mass of the W+W− system, as well as jet-related observables such as the leading jet transverse momentum and the jet multiplicity. Limits on anomalous triple-gauge-boson couplings are obtained in a phase space where interference between the Standard Model amplitude and the anomalous amplitude is enhanced

    Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents

    Get PDF
    Non-ionizing energy loss causes bulk damage to the silicon sensors of the ATLAS pixel and strip detectors. This damage has important implications for data-taking operations, charged-particle track reconstruction, detector simulations, and physics analysis. This paper presents simulations and measurements of the leakage current in the ATLAS pixel detector and semiconductor tracker as a function of location in the detector and time, using data collected in Run 1 (2010–2012) and Run 2 (2015–2018) of the Large Hadron Collider. The extracted fluence shows a much stronger |z|-dependence in the innermost layers than is seen in simulation. Furthermore, the overall fluence on the second innermost layer is significantly higher than in simulation, with better agreement in layers at higher radii. These measurements are important for validating the simulation models and can be used in part to justify safety factors for future detector designs and interventions.publishedVersio

    Innovation in Gastroenterology—Can We Do Better?

    No full text
    The health system can reap significant benefits by adopting and implementing innovative measures, as was recently demonstrated and emphasized during the COVID-19 pandemic. Herein, we present our bird’s eye view of gastroenterology’s innovative technologies via utilizing a text-mining technique. We analyzed five research fields that comply with innovation: artificial intelligence (AI), virtual reality (VR), telemedicine, the microbiome, and advanced endoscopy. According to gastroenterology literature, the two most innovative fields were the microbiome and advanced endoscopy. Though artificial intelligence (AI), virtual reality (VR), and telemedicine trailed behind, the number of AI publications in gastroenterology has shown an exponential trend in the last couple of years. While VR and telemedicine are neglected compared to other fields, their implementation could improve physician and patient training, patient access to care, cost reduction, and patient outcomes

    Obstetric and Neonatal Outcomes following COVID-19 Vaccination in Pregnancy

    No full text
    COVID-19 infection imposes a risk for pregnant individuals and may lead to adverse maternal and obstetric outcomes. This is a retrospective cohort study of all women giving birth between March and July 2021 at a single tertiary center. Obstetric and neonatal outcomes were compared between vaccinated and non-vaccinated pregnant women with singleton pregnancies. Women with prior COVID-19 infection, multiple gestations and stillbirth were excluded from the study. Of 4708 women who delivered during the study period, 3700 met the eligibility criteria, of whom 3240 were vaccinated during pregnancy. Compared with the non-vaccinated group, the vaccinated group was characterized by a lower rate of smoking (3.70% vs. 6.67%, p = 0.0028), whereasother maternal characteristics were not significantly different. Multivariable analysis demonstrated that COVID-19 mRNA vaccination was not significantly associated with increased risk of preterm birth as well as other adverse obstetric outcomes including hypertensive diseases of pregnancy, cesarean delivery and small for gestational age. However, a significantly lower risk for meconium-stained amniotic fluid was observed among the vaccinated group (adjusted odds ratio 0.63; 95% confidence interval, 0.46&ndash;0.86, p = 0.0039). Moreover, the vaccine was not significantly associated with increased risk of neonatal adverse outcomes including respiratory complications and NICU hospitalization. In conclusion, BNT162b2 messenger RNA vaccination during pregnancy was not associated with an increased rate of adverse obstetric and neonatal outcomes. Therefore, in view of its safety on one hand, and the risk associated with COVID-19 disease in pregnancy on the other hand, BNT 162b2 COVID-19 vaccine should be recommended for pregnant women

    Personalized charts for the fetal corpus callosum length

    No full text
    <p><b>Objective:</b> To personally customize the antenatal ultrasound charts for the fetal corpus callosum (CC) length.</p> <p><b>Methods:</b> A retrospective analysis of fetal neuro-sonography scans. Cases were grouped as normal neuro-sonographic evaluation (normal) or as high risk and suspected brain anomaly (abnormal). The normal group was subcategorized according to Cignini’s CC length charts. Data of fetuses with a CC length between the 5th–95th percentile served for creating new charts, describing the ratio of the CC length to the major biometric parameters as a function of gestational age (GA).</p> <p><b>Results:</b> A total of 410 measurements were included. Of them 255 were normal and 155 abnormal. The CC length/estimated fetal weight (EFW) ratio had the strongest linear association with GA (<i>R</i><sup>2</sup> = 0.929). Applying charts using this ratio to the normal group, significantly increased the percent of CC length measurements defined as normal from 84.7 to 94.5% (<i>p</i> < .001). Conversely, applying these charts to the abnormal group nonsignificantly decreased the number of measurement defined as normal from 89 to 83.2% (<i>p</i> = .137)</p> <p><b>Conclusions:</b> The CC length/EFW ratio is strongly and linearly associated with GA. Using this personalized ratio may improve the diagnostic accuracy of CC evaluation by adjusting the CC length to the fetus natural proportions.</p
    corecore