Modification Factor for Shear Capacity of Lightweight Concrete Beams
yesThe validity of the modification factor specified in the ACI 318-11 shear provision for concrete members to account for the reduced frictional properties along crack interfaces is examined using a comprehensive database comprised of 1716 normalweight concrete (NWC) beam specimens, 73 all-lightweight concrete (ALWC) beam specimens, and 54 sand-lightweight concrete (SLWC) beam specimens without shear reinforcement. Comparisons of measured and predicted shear capacities of concrete beams in the database show that ACI 318-11 provisions for shear-transfer capacity of concrete are less conservative for lightweight concrete (LWC) beams than NWC beams. A rational approach based on the upper-bound theorem of concrete plasticity has been developed to assess the reduced aggregate interlock along the crack interfaces and predict the shear-transfer capacity of concrete. A simplified model for the modification factor is then proposed as a function of the compressive strength and dry density of concrete and maximum aggregate size on the basis of analytical parametric studies on the ratios of shear-transfer capacity of LWC to that of the companion NWC. The proposed modification factor decreases with the decrease in the dry density of concrete, gives closer predictions to experimental results than does the ACI 318-11 shear provision and, overall, improves the safety of shear capacity of LWC beams
Shear capacity of reinforced concrete corbels using mechanism analysis
A mechanism analysis is developed to predict the shear capacity of reinforced concrete corbels. Based on shear failure observed in experimental tests, kinematically admissible failure mechanisms are idealised as an assemblage of two rigid blocks separated by a failure plane of displacement discontinuity. Shear capacity predictions obtained from the developed mechanism analysis are in better agreement with corbel test results of a comprehensive database compiled from the available literature than other existing models for corbels. The developed mechanism model shows that the shear capacity of corbels generally decreases with the increase of shear span-to-depth ratio, increases with the increase of main longitudinal reinforcement up to a certain limit beyond which it remains constant, and decreases with the increase of horizontal applied loads. It also demonstrates that the smaller the shear span-to-overall depth ratio of corbels, the more effective the horizontal shear reinforcement
Shear Capacity of Monolithic Concrete Joints without Transverse Reinforcement.
yesA mechanism analysis based on the upper-bound theorem of concrete plasticity for monolithic concrete joints without transverse reinforcement is presented. Concrete is modelled as a rigid–perfectly plastic material obeying modified Coulomb failure criteria. Existing stress–strain relationships of concrete in compression and tension are comprehensively modified using the crack band theory to allow for concrete type and maximum aggregate size. Simple equations for the effectiveness factor for compression, ratio of effective tensile strength to compressive strength and angle of concrete friction are then mathematically developed using the modified stress–strain relationships of concrete. In addition, 12 push-off specimens made of all-lightweight, sand–lightweight and normal-weight concrete having maximum aggregate size between 4 and 19 mm were physically tested. Test results and mechanism analysis clearly showed that the shear capacity of monolithic concrete joints increased with the increase of the maximum aggregate size and dry density of concrete. The mean and standard deviation of the ratio between experimentally measured and predicted (by the mechanism analysis shear capacities) are 1·01 and 0·16 respectively, showing a closer prediction and less variation than Vecchio and Collins' equation, regardless of concrete type and maximum aggregate size
Shear friction strength of monolithic concrete interfaces
YesThis paper presents an integrated model for shear friction strength of monolithic concrete interfaces derived from the upper-bound theorem of concrete plasticity. The model accounts for the effects of applied axial stresses and transverse reinforcement on the shear friction action at interfacial shear cracks. Simple equations were also developed to generalize the effectiveness factor for compression, ratio of effective tensile to compressive strengths and angle of concrete friction. The reliability of the proposed model was then verified through comparisons with previous empirical equations and 103 push-off test specimens compiled from different sources in the literature.
The previous equations considerably underestimate the concrete shear transfer capacity and the underestimation is notable for the interfaces subjected to additional axial stresses. The proposed model provides superior accuracy in predicting the shear friction strength, resulting in a mean between experimental and predicted friction strengths of 0.97 and least scatter. Moreover, the proposed model has consistent trends with test results in evaluating the effect of various parameters on the shear friction strength
Assessment of web crippling design provisions for application to proprietary soldier beams
Structures used for temporary works are lightweight so that they are easy to transport, erect
and dismantle. Particular care should be taken in their design as local instabilities could arise due to
their thin-walled nature. This article presents 12 tests on proprietary soldier beams subjected to two
concentrate opposing loads applied simultaneously. The geometry of the proprietary beams feature
cold-formed C-shaped sections with web holes connected back to back with internal spacers. In the
absence of design rules for application to such members, the experimental results are used in the
present investigation to assess the suitability of the provisions for the web crippling design of coldformed steel members as well as existing design methods from the literature, which account for the
effect of perforations in the web. Experimental and predicted resistances are compared and design
recommendations are provided.Leada Acro
An experimental and analytical investigation of reinforced concrete beam-column joints strengthened with a range of CFRP schemes applied only to the beam
This paper investigates the experimental and analytical behaviour of beam-column joints that are subjected to a combination of torque, flexural and direct shear forces, where different Carbon Fibre Polymer (CFRP) strengthening wraps have been applied only to the beam. These wrapping schemes have previously been determined by the research community as an effective method of enhancing the torsional capacities of simply supported reinforced concrete beams. In this investigation, four 3/4-scale exterior beam-column joints were subjected to combined monotonic loading; three different beam wrapping schemes were employed to strengthen the beam region of the joint. The paper suggests a series of rational formulae, based on the space truss mechanism, which can be used to evaluate the joint shear demand of the beams wrapped in these various ways. Further, an iterative model, based on the average stress-strain method, has been introduced to predict joint strength. The proposed analytical approaches show good agreement with the experimental results. The experimental outcomes along with the adopted analytical methods reflect the consistent influence of the wrapping ratio, the interaction between the combined forces, the concrete strut capacity and the fibre orientation on the joint forces, the failure mode and the distortion levels. A large rise in the strut force resulting from shear stresses generated from this combination of forces is demonstrated and leads to a sudden-brittle failure. Likewise, increases in the beams’ main steel rebar strains are identified at the column face, again influenced by the load interactions and the wrapping systems used
- …