296 research outputs found

    Congenital Midline Upper Lip Sinuses: 3 Rare Cases

    Get PDF
    Congenital sinuses of the upper lip are rare congenital malformations. There have been only 40 cases described in the literature. We report 3 cases of congenital midline upper lip sinus in Caucasian children. Two of those lesions were associated with other anomalies (complete cleft palate and hemifacial macrosomia or submucous cleft palate with bifid uvula). The pathophysiology remains unexplained yet. Congenital upper lip sinuses can be considered as possible microforms of cleft-lips. Associated anomalies are frequent and must be sought. The treatment is a full excision of the sinus tract and of the skin around the punctum in order to avoid risks of recurrence

    Carotid stenting: is there an operator effect? A pooled analysis from the carotid stenting trialists' collaboration.

    No full text
    BACKGROUND AND PURPOSE: Randomized clinical trials show higher 30-day risk of stroke or death after carotid artery stenting compared with surgery. We examined whether operator experience is associated with 30-day risk of stroke or death in the Carotid Stenting Trialists' Collaboration database. METHODS: The Carotid Stenting Trialists' Collaboration is a pooled individual patient database including all patients recruited in 3 randomized trials of stenting versus endarterectomy for symptomatic carotid stenosis (Endarterectomy Versus Angioplasty in patients with Symptomatic Severe Carotid Stenosis trial, Stent-Protected Angioplasty versus Carotid Endarterectomy trial, and International Carotid Stenting Study). Lifetime carotid artery stenting experience, lifetime experience in stenting procedures excluding the carotid, and annual number of procedures performed within the trial (in-trial volume), divided into tertiles, were used to measure operator experience. The outcome event was the occurrence of any stroke or death within 30 days of the procedure. The analysis was done per protocol. RESULTS: Among 1546 patients who underwent carotid artery stenting, 120 (7.8%) had a stroke or death within 30 days of the procedure. The 30-day risk of stroke or death did not differ according to operator lifetime carotid artery stenting experience (P=0.8) or operator lifetime stenting experience excluding the carotid (P=0.7). In contrast, the 30-day risk of stroke or death was significantly higher in patients treated by operators with low (mean ≤3.2 procedures/y; risk 10.1%; adjusted risk ratio=2.30 [1.36-3.87]) and intermediate annual in-trial volumes (3.2-5.6 procedures/y; 8.4%; adjusted risk ratio=1.93 [1.14-3.27]) compared with patients treated by high annual in-trial volume operators (>5.6 procedures/y; 5.1%). CONCLUSIONS: Carotid stenting should only be performed by operators with annual procedure volume ≥6 cases per year

    Polyelectrolyte multilayer formation: electrostatics and short-range interactions

    Full text link
    We investigate the phenomenon of multilayer formation via layer-by-layer deposition of alternating charge polyelectrolytes. Using mean-field theory, we find that a strong short-range attraction between the two types of polymer chains is essential for the formation of multilayers. The dependence of the required short-range attraction on the polymer charge fraction and salt concentration is calculated. For weak short-range attraction between any two adjacent layers, the adsorbed amount (per added layer) decays as the distance from the surface increases, until the chains stop adsorbing altogether. For strong short-range attraction, the adsorbed amount per layer increases after an initial decrease, and finally it stabilizes in the form of a polyelectrolyte multilayer that can be repeated many times.Comment: 8 pages, 7 figure

    The CMS event builder demonstrator based on Myrinet

    Get PDF
    The data acquisition system for the CMS experiment at the Large Hadron Collider (LHC) will require a large and high performance event building network. Several switch technologies are currently being evaluated in order to compare different architectures for the event builder. One candidate is Myrinet. This paper describes the demonstrator which has been set up to study a small-scale (8*8) event builder based on a Myrinet switch. Measurements are presented on throughput, overhead and scaling for various traffic conditions. Results are shown on event building with a push architecture. (6 refs)

    A software approach for readout and data acquisition in CMS

    Get PDF
    Traditional systems dominated by performance constraints tend to neglect other qualities such as maintainability and configurability. Object-Orientation allows one to encapsulate the technology differences in communication sub-systems and to provide a uniform view of data transport layer to the systems engineer. We applied this paradigm to the design and implementation of intelligent data servers in the Compact Muon Solenoid (CMS) data acquisition system at CERN to easily exploiting the physical communication resources of the available equipment. CMS is a high-energy physics experiment under study that incorporates a highly distributed data acquisition system. This paper outlines the architecture of one part, the so called Readout Unit, and shows how we can exploit the object advantage for systems with specific data rate requirements. A C++ streams communication layer with zero copying functionality has been established for UDP, TCP, DLPI and specific Myrinet and VME bus communication on the VxWorks real-time operating system. This software provides performance close to the hardware channel and hides communication details from the application programmers. (28 refs)

    The Readability of Information and Consent Forms in Clinical Research in France

    Get PDF
    BACKGROUND: Quantitative tools have been developed to evaluate the readability of written documents and have been used in several studies to evaluate information and consent forms. These studies all showed that such documents had a low level of readability. Our objective is to evaluate the readability of Information and Consent Forms (ICFs) used in clinical research. METHODS AND FINDINGS: Clinical research protocols were collected from four public clinical research centers in France. Readability was evaluated based on three criteria: the presence of an illustration, the length of the text and its Flesch score. Potential effects of protocol characteristics on the length and readability of the ICFs were determined. Medical and statutory parts of the ICF form were analyzed separately. The readability of these documents was compared with that of everyday contracts, press articles, literary extracts and political speeches. We included 209 protocols and the corresponding 275 ICFs. The median length was 1304 words. Their Flesch readability scores were low (median: 24), and only about half that of selected press articles. ICF s for industrially sponsored and randomized protocols were the longest and had the highest readability scores. More than half (52%) of the text in ICFs concerned medical information, and this information was statistically (p<0.05) more readable (Flesch: 28) than statutory information (Flesch: 21). CONCLUSION: Regardless of the field of research, the ICFs for protocols included had poor readability scores. However, a prospective analysis of this test in French should be carried out before it is put into general use

    Digital Drugs: an anatomy of new medicines

    Get PDF
    Medicines are digitalized as aspects of their regulation and use are embodied in or draw from interlinked computerized systems and databases. This paper considers how this development changes the delivery of health care, the pharma industry, and regulatory and professional structures, as it reconfigures the material character of drugs themselves. It draws on the concept of assemblage in presenting a theory-based analysis that explores digital drugs’ ontological status including how they embody benefit and value. The paper addresses three interconnected domains – that of use of drugs (practice), of research (epistemology) and of regulation (structures)

    Reduced-Dose Intravenous Thrombolysis for Acute Intermediate-High-risk Pulmonary Embolism: Rationale and Design of the Pulmonary Embolism International THrOmbolysis (PEITHO)-3 trial

    Get PDF
    Intermediate-high-risk pulmonary embolism (PE) is characterized by right ventricular (RV) dysfunction and elevated circulating cardiac troponin levels despite apparent hemodynamic stability at presentation. In these patients, full-dose systemic thrombolysis reduced the risk of hemodynamic decompensation or death but increased the risk of life-threatening bleeding. Reduced-dose thrombolysis may be capable of improving safety while maintaining reperfusion efficacy. The Pulmonary Embolism International THrOmbolysis (PEITHO)-3 study (ClinicalTrials.gov Identifier: NCT04430569) is a randomized, placebo-controlled, double-blind, multicenter, multinational trial with long-term follow-up. We will compare the efficacy and safety of a reduced-dose alteplase regimen with standard heparin anticoagulation. Patients with intermediate-high-risk PE will also fulfill at least one clinical criterion of severity: systolic blood pressure ≤110 mm Hg, respiratory rate &gt;20 breaths/min, or history of heart failure. The primary efficacy outcome is the composite of all-cause death, hemodynamic decompensation, or PE recurrence within 30 days of randomization. Key secondary outcomes, to be included in hierarchical analysis, are fatal or GUSTO severe or life-threatening bleeding; net clinical benefit (primary efficacy outcome plus severe or life-threatening bleeding); and all-cause death, all within 30 days. All outcomes will be adjudicated by an independent committee. Further outcomes include PE-related death, hemodynamic decompensation, or stroke within 30 days; dyspnea, functional limitation, or RV dysfunction at 6 months and 2 years; and utilization of health care resources within 30 days and 2 years. The study is planned to enroll 650 patients. The results are expected to have a major impact on risk-adjusted treatment of acute PE and inform guideline recommendations

    Proceedings from the 2nd European Clinical Consensus Conference for device-based therapies for hypertension: state of the art and considerations for the future.

    Get PDF
    The interest in RDN for hypertension has fluctuated recently, with a flurry of initial enthusiasm followed by sudden loss of interest by researchers and device manufacturers, with an almost as sudden resurgence in clinical trials activity and device innovation more recently. There is widespread consensus that this therapeutic strategy can be effective, at least for some of the technologies available. Major uncertainties remain as to the clinical role of RDN, and whether any of the emerging technologies such as AV-anastomosis formation, carotid body ablation, carotid bulb expansion, or baroreflex stimulation will have a future as effective treatment options in patients with hypertension. In our first consensus report in 2015, the European Expert Group pointed to the major unmet need of standardization of measurements, trial design and procedural performance.6 With the large number of different technologies currently in the pipeline, this need has even increased. Only through high-quality, collaborative research and openness to new methods for recruitment, patient selection, and assessment of outcomes will it be possible to establish incontrovertibly whether device therapies for hypertension are effective and what are preferred patient populations. Once the proof of concept is established, further studies with a design relevant to clinical reality will be needed to establish the place of new devices in the treatment armoury. The clinical and research community has a large responsibility to prove or disprove the value of new therapies, in order to ensure that antihypertensive devices provide future patients with the greatest benefit and the smallest risk. copy; The Author 2017
    corecore