29 research outputs found
Plasma AÎČ42/AÎČ40 and phosphoâtau217 concentration ratios increase the accuracy of amyloid PET classification in preclinical Alzheimer's disease
INTRODUCTION: Incorporating blood-based Alzheimer's disease biomarkers such as tau and amyloid beta (AÎČ) into screening algorithms may improve screening efficiency. METHODS: Plasma AÎČ, phosphorylated tau (p-tau)181, and p-tau217 concentration levels from AHEAD 3-45 study participants were measured using mass spectrometry. Tau concentration ratios for each proteoform were calculated to normalize for inter-individual differences. Receiver operating characteristic (ROC) curve analysis was performed for each biomarker against amyloid positivity, defined by > 20 Centiloids. Mixture of experts analysis assessed the value of including tau concentration ratios into the existing predictive algorithm for amyloid positron emission tomography status. RESULTS: The area under the receiver operating curve (AUC) was 0.87 for AÎČ42/AÎČ40, 0.74 for phosphorylated variant p-tau181 ratio (p-tau181/np-tau181), and 0.92 for phosphorylated variant p-tau217 ratio (p-tau217/np-tau217). The Plasma Predicted Centiloid (PPC), a predictive model including p-tau217/np-tau217, AÎČ42/AÎČ40, age, and apolipoprotein E improved AUC to 0.95. DISCUSSION: Including plasma p-tau217/np-tau217 along with AÎČ42/AÎČ40 in predictive algorithms may streamline screening preclinical individuals into anti-amyloid clinical trials. CLINICALTRIALS: gov Identifier: NCT04468659 HIGHLIGHTS: The addition of plasma phosphorylated variant p-tau217 ratio (p-tau217/np-tau217) significantly improved plasma biomarker algorithms for identifying preclinical amyloid positron emission tomography positivity. Prediction performance at higher NAV Centiloid levels was improved with p-tau217/np-tau217. All models generated for this study are incorporated into the Plasma Predicted Centiloid (PPC) app for public use
Antennas for the detection of radio emission pulses from cosmic-ray induced air showers at the Pierre Auger Observatory
The Pierre Auger Observatory is exploring the potential of the radio detection technique to study extensive air showers induced by ultra-high energy cosmic rays. The Auger Engineering Radio Array (AERA) addresses both technological and scientific aspects of the radio technique. A first phase of AERA has been operating since September 2010 with detector stations observing radio signals at frequencies between 30 and 80 MHz. In this paper we present comparative studies to identify and optimize the antenna design for the final configuration of AERA consisting of 160 individual radio detector stations. The transient nature of the air shower signal requires a detailed description of the antenna sensor. As the ultra-wideband reception of pulses is not widely discussed in antenna literature, we review the relevant antenna characteristics and enhance theoretical considerations towards the impulse response of antennas including polarization effects and multiple signal reflections. On the basis of the vector effective length we study the transient response characteristics of three candidate antennas in the time domain. Observing the variation of the continuous galactic background intensity we rank the antennas with respect to the noise level added to the galactic signal
Measurement of the Cosmic Ray e(+)+e(-) Spectrum from 20 GeV to 1 TeV with the Fermi Large Area Telescope
Designed as a high-sensitivity gamma-ray observatory, the Fermi Large Area Telescope is also an electron detector with a large acceptance exceeding 2 m2 sr at 300 GeV. Building on the gamma-ray analysis, we have developed an efficient electron detection strategy which provides sufficient background rejection for measurement of the steeply falling electron spectrum up to 1 TeV. Our high precision data show that the electron spectrum falls with energy as E-3.0 and does not exhibit prominent spectral features. Interpretations in terms of a conventional diffusive model as well as a potential local extra component are briefly discussed
Testing hadronic-model predictions of depth of maximum of air-shower profiles and ground-particle signals using hybrid data of the Pierre Auger Observatory
We test the predictions of hadronic interaction models regarding the depth of maximum of air-shower
profiles, Xmax , and ground-particle signals in water-Cherenkov detectors at 1000 m from the shower core,
SĂ°1000Ă, using the data from the fluorescence and surface detectors of the Pierre Auger Observatory. The
test consists of fitting the measured two-dimensional (SĂ°1000Ă, Xmax ) distributions using templates for
simulated air showers produced with hadronic interaction models E pos-LHC , QGSJ et-II -04, SIBYLL 2.3d and
leaving the scales of predicted Xmax and the signals from hadronic component at ground as free-fit
parameters. The method relies on the assumption that the mass composition remains the same at all zenith
angles, while the longitudinal shower development and attenuation of ground signal depend on the mass
composition in a correlated way. The analysis was applied to 2239 events detected by both the fluorescence
and surface detectors of the Pierre Auger Observatory with energies between 10 18.5 eV to 10 19.0 eV and
zenith angles below 60°. We found, that within the assumptions of the method, the best description of the
data is achieved if the predictions of the hadronic interaction models are shifted to deeper Xmax values and
larger hadronic signals at all zenith angles. Given the magnitude of the shifts and the data sample size, the
statistical significance of the improvement of data description using the modifications considered in the
paper is larger than 5Ï even for any linear combination of experimental systematic uncertainties