4,213 research outputs found
Optical coherence tomography-based consensus definition for lamellar macular hole.
BackgroundA consensus on an optical coherence tomography definition of lamellar macular hole (LMH) and similar conditions is needed.MethodsThe panel reviewed relevant peer-reviewed literature to reach an accord on LMH definition and to differentiate LMH from other similar conditions.ResultsThe panel reached a consensus on the definition of three clinical entities: LMH, epiretinal membrane (ERM) foveoschisis and macular pseudohole (MPH). LMH definition is based on three mandatory criteria and three optional anatomical features. The three mandatory criteria are the presence of irregular foveal contour, the presence of a foveal cavity with undermined edges and the apparent loss of foveal tissue. Optional anatomical features include the presence of epiretinal proliferation, the presence of a central foveal bump and the disruption of the ellipsoid zone. ERM foveoschisis definition is based on two mandatory criteria: the presence of ERM and the presence of schisis at the level of Henle's fibre layer. Three optional anatomical features can also be present: the presence of microcystoid spaces in the inner nuclear layer (INL), an increase of retinal thickness and the presence of retinal wrinkling. MPH definition is based on three mandatory criteria and two optional anatomical features. Mandatory criteria include the presence of a foveal sparing ERM, the presence of a steepened foveal profile and an increased central retinal thickness. Optional anatomical features are the presence of microcystoid spaces in the INL and a normal retinal thickness.ConclusionsThe use of the proposed definitions may provide uniform language for clinicians and future research
SPRK: A Low-Cost Stewart Platform For Motion Study In Surgical Robotics
To simulate body organ motion due to breathing, heart beats, or peristaltic
movements, we designed a low-cost, miniaturized SPRK (Stewart Platform Research
Kit) to translate and rotate phantom tissue. This platform is 20cm x 20cm x
10cm to fit in the workspace of a da Vinci Research Kit (DVRK) surgical robot
and costs $250, two orders of magnitude less than a commercial Stewart
platform. The platform has a range of motion of +/- 1.27 cm in translation
along x, y, and z directions and has motion modes for sinusoidal motion and
breathing-inspired motion. Modular platform mounts were also designed for
pattern cutting and debridement experiments. The platform's positional
controller has a time-constant of 0.2 seconds and the root-mean-square error is
1.22 mm, 1.07 mm, and 0.20 mm in x, y, and z directions respectively. All the
details, CAD models, and control software for the platform is available at
github.com/BerkeleyAutomation/sprk
Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery
One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions
Autonomous Tissue Scanning under Free-Form Motion for Intraoperative Tissue Characterisation
In Minimally Invasive Surgery (MIS), tissue scanning with imaging probes is
required for subsurface visualisation to characterise the state of the tissue.
However, scanning of large tissue surfaces in the presence of deformation is a
challenging task for the surgeon. Recently, robot-assisted local tissue
scanning has been investigated for motion stabilisation of imaging probes to
facilitate the capturing of good quality images and reduce the surgeon's
cognitive load. Nonetheless, these approaches require the tissue surface to be
static or deform with periodic motion. To eliminate these assumptions, we
propose a visual servoing framework for autonomous tissue scanning, able to
deal with free-form tissue deformation. The 3D structure of the surgical scene
is recovered and a feature-based method is proposed to estimate the motion of
the tissue in real-time. A desired scanning trajectory is manually defined on a
reference frame and continuously updated using projective geometry to follow
the tissue motion and control the movement of the robotic arm. The advantage of
the proposed method is that it does not require the learning of the tissue
motion prior to scanning and can deal with free-form deformation. We deployed
this framework on the da Vinci surgical robot using the da Vinci Research Kit
(dVRK) for Ultrasound tissue scanning. Since the framework does not rely on
information from the Ultrasound data, it can be easily extended to other
probe-based imaging modalities.Comment: 7 pages, 5 figures, ICRA 202
Computer- and robot-assisted Medical Intervention
Medical robotics includes assistive devices used by the physician in order to
make his/her diagnostic or therapeutic practices easier and more efficient.
This chapter focuses on such systems. It introduces the general field of
Computer-Assisted Medical Interventions, its aims, its different components and
describes the place of robots in that context. The evolutions in terms of
general design and control paradigms in the development of medical robots are
presented and issues specific to that application domain are discussed. A view
of existing systems, on-going developments and future trends is given. A
case-study is detailed. Other types of robotic help in the medical environment
(such as for assisting a handicapped person, for rehabilitation of a patient or
for replacement of some damaged/suppressed limbs or organs) are out of the
scope of this chapter.Comment: Handbook of Automation, Shimon Nof (Ed.) (2009) 000-00
Robot Autonomy for Surgery
Autonomous surgery involves having surgical tasks performed by a robot
operating under its own will, with partial or no human involvement. There are
several important advantages of automation in surgery, which include increasing
precision of care due to sub-millimeter robot control, real-time utilization of
biosignals for interventional care, improvements to surgical efficiency and
execution, and computer-aided guidance under various medical imaging and
sensing modalities. While these methods may displace some tasks of surgical
teams and individual surgeons, they also present new capabilities in
interventions that are too difficult or go beyond the skills of a human. In
this chapter, we provide an overview of robot autonomy in commercial use and in
research, and present some of the challenges faced in developing autonomous
surgical robots
Caveats on the first-generation da Vinci Research Kit: latent technical constraints and essential calibrations
Telesurgical robotic systems provide a well established form of assistance in
the operating theater, with evidence of growing uptake in recent years. Until
now, the da Vinci surgical system (Intuitive Surgical Inc, Sunnyvale,
California) has been the most widely adopted robot of this kind, with more than
6,700 systems in current clinical use worldwide [1]. To accelerate research on
robotic-assisted surgery, the retired first-generation da Vinci robots have
been redeployed for research use as "da Vinci Research Kits" (dVRKs), which
have been distributed to research institutions around the world to support both
training and research in the sector. In the past ten years, a great amount of
research on the dVRK has been carried out across a vast range of research
topics. During this extensive and distributed process, common technical issues
have been identified that are buried deep within the dVRK research and
development architecture, and were found to be common among dVRK user feedback,
regardless of the breadth and disparity of research directions identified. This
paper gathers and analyzes the most significant of these, with a focus on the
technical constraints of the first-generation dVRK, which both existing and
prospective users should be aware of before embarking onto dVRK-related
research. The hope is that this review will aid users in identifying and
addressing common limitations of the systems promptly, thus helping to
accelerate progress in the field.Comment: 15 pages, 7 figure
- …