90,026 research outputs found
The 'upstream wake' of swimming and flying animals and its correlation with propulsive efficiency
The interaction between swimming and flying animals and their fluid environments generates downstream wake structures such as vortices. In most studies, the upstream flow in front of the animal is neglected. In this study, we demonstrate the existence of upstream fluid structures even though the upstream flow is quiescent or possesses a uniform incoming velocity. Using a computational model, the flow generated by a swimmer (an oscillating flexible plate) is simulated and a new fluid mechanical analysis is applied to the flow to identify the upstream fluid structures. These upstream structures show the exact portion of fluid that is going to interact with the swimmer. A mass flow rate is then defined based on the upstream structures, and a metric for propulsive efficiency is established using the mass flow rate and the kinematics of the swimmer. We propose that the unsteady mass flow rate defined by the upstream fluid structures can be used as a metric to measure and objectively compare the efficiency of locomotion in water and air
A review of advances in pixel detectors for experiments with high rate and radiation
The Large Hadron Collider (LHC) experiments ATLAS and CMS have established
hybrid pixel detectors as the instrument of choice for particle tracking and
vertexing in high rate and radiation environments, as they operate close to the
LHC interaction points. With the High Luminosity-LHC upgrade now in sight, for
which the tracking detectors will be completely replaced, new generations of
pixel detectors are being devised. They have to address enormous challenges in
terms of data throughput and radiation levels, ionizing and non-ionizing, that
harm the sensing and readout parts of pixel detectors alike. Advances in
microelectronics and microprocessing technologies now enable large scale
detector designs with unprecedented performance in measurement precision (space
and time), radiation hard sensors and readout chips, hybridization techniques,
lightweight supports, and fully monolithic approaches to meet these challenges.
This paper reviews the world-wide effort on these developments.Comment: 84 pages with 46 figures. Review article.For submission to Rep. Prog.
Phy
Vertex-Detector R&D for CLIC
A detector concept based on hybrid planar pixel-detector technology is under
development for the CLIC vertex detector. It comprises fast, low-power and
small-pitch readout ASICs implemented in 65 nm CMOS technology (CLICpix)
coupled to ultra-thin sensors via low-mass interconnects. The power dissipation
of the readout chips is reduced by means of power pulsing, allowing for a
cooling system based on forced gas flow. In this paper the CLIC vertex-detector
requirements are reviewed and the current status of R&D on sensors, readout and
detector integration is presented.Comment: 12 pages, 7 figures. Talk presented at the 13th Topical Seminar on
Innovative Particle and Radiation Detectors (IPRD13), 7 - 10 October 2013,
Siena, Ital
Production and Characterisation of SLID Interconnected n-in-p Pixel Modules with 75 Micrometer Thin Silicon Sensors
The performance of pixel modules built from 75 micrometer thin silicon
sensors and ATLAS read-out chips employing the Solid Liquid InterDiffusion
(SLID) interconnection technology is presented. This technology, developed by
the Fraunhofer EMFT, is a possible alternative to the standard bump-bonding. It
allows for stacking of different interconnected chip and sensor layers without
destroying the already formed bonds. In combination with Inter-Chip-Vias (ICVs)
this paves the way for vertical integration. Both technologies are combined in
a pixel module concept which is the basis for the modules discussed in this
paper.
Mechanical and electrical parameters of pixel modules employing both SLID
interconnections and sensors of 75 micrometer thickness are covered. The
mechanical features discussed include the interconnection efficiency, alignment
precision and mechanical strength. The electrical properties comprise the
leakage currents, tuning characteristics, charge collection, cluster sizes and
hit efficiencies. Targeting at a usage at the high luminosity upgrade of the
LHC accelerator called HL-LHC, the results were obtained before and after
irradiation up to fluences of
(1 MeV neutrons).Comment: 16 pages, 22 figure
Technical Design Report for the PANDA Micro Vertex Detector
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is
outlined
The Palomar Testbed Interferometer
The Palomar Testbed Interferometer (PTI) is a long-baseline infrared
interferometer located at Palomar Observatory, California. It was built as a
testbed for interferometric techniques applicable to the Keck Interferometer.
First fringes were obtained in July 1995. PTI implements a dual-star
architecture, tracking two stars simultaneously for phase referencing and
narrow-angle astrometry. The three fixed 40-cm apertures can be combined
pair-wise to provide baselines to 110 m. The interferometer actively tracks the
white-light fringe using an array detector at 2.2 um and active delay lines
with a range of +/- 38 m. Laser metrology of the delay lines allows for servo
control, and laser metrology of the complete optical path enables narrow-angle
astrometric measurements. The instrument is highly automated, using a
multiprocessing computer system for instrument control and sequencing.Comment: ApJ in Press (Jan 99) Fig 1 available from
http://huey.jpl.nasa.gov/~bode/ptiPicture.html, revised duging copy edi
2D Detectors for Particle Physics and for Imaging Applications
The demands on detectors for particle detection as well as for medical and
astronomical X-ray imaging are continuously pushing the development of novel
pixel detectors. The state of the art in pixel detector technology to date are
hybrid pixel detectors in which sensor and read-out integrated circuits are
processed on different substrates and connected via high density interconnect
structures. While these detectors are technologically mastered such that large
scale particle detectors can be and are being built, the demands for improved
performance for the next generation particle detectors ask for the development
of monolithic or semi-monolithic approaches. Given the fact that the demands
for medical imaging are different in some key aspects, developments for these
applications, which started as particle physics spin-off, are becomming rather
independent. New approaches are leading to novel signal processing concepts and
interconnect technologies to satisfy the need for very high dynamic range and
large area detectors. The present state in hybrid and (semi-)monolithic pixel
detector development and their different approaches for particle physics and
imaging application is reviewed
An overview of a Lagrangian method for analysis of animal wake dynamics
The fluid dynamic analysis of animal wakes is becoming increasingly popular in studies of animal swimming and flying, due in part to the development of quantitative flow visualization techniques such as digital particle imaging velocimetry (DPIV). In most studies, quasi-steady flow is assumed and the flow analysis is based on velocity and/or vorticity fields measured at a single time instant during the stroke cycle. The assumption of quasi-steady flow leads to neglect of unsteady (time-dependent) wake vortex added-mass effects, which can contribute significantly to the instantaneous locomotive forces. In this paper we review a Lagrangian approach recently introduced to determine unsteady wake vortex structure by tracking the trajectories of individual fluid particles in the flow, rather than by analyzing the velocity/vorticity fields at fixed locations and single instants in time as in the Eulerian perspective. Once the momentum of the wake vortex and its added mass are determined, the corresponding unsteady locomotive forces can be quantified. Unlike previous studies that estimated the time-averaged forces over the stroke cycle, this approach enables study of how instantaneous locomotive forces evolve over time. The utility of this method for analyses of DPIV velocity measurements is explored, with the goal of demonstrating its applicability to data that are typically available to investigators studying animal swimming and flying. The methods are equally applicable to computational fluid dynamics studies where velocity field calculations are available
- …