254 research outputs found

    Low-Pass filtering approach via empirical mode decomposition improves short-scale entropy-based complexity estimation of QT interval variability in long QT syndrome type 1 patients

    Get PDF
    CITATION: Bari, V. et al. 2014. Low-Pass filtering approach via empirical mode decomposition improves short-scale entropy-based complexity estimation of QT interval variability in long QT syndrome type 1 patients. Entropy, 16(9):4839-4854, doi:10.3390/e16094839.The original publication is available at http://www.mdpi.com/journal/entropyEntropy-based complexity of cardiovascular variability at short time scales is largely dependent on the noise and/or action of neural circuits operating at high frequencies. This study proposes a technique for canceling fast variations from cardiovascular variability, thus limiting the effect of these overwhelming influences on entropy-based complexity. The low-pass filtering approach is based on the computation of the fastest intrinsic mode function via empirical mode decomposition (EMD) and its subtraction from the original variability. Sample entropy was exploited to estimate complexity. The procedure was applied to heart period (HP) and QT (interval from Q-wave onset to T-wave end) variability derived from 24-hour Holter recordings in 14 non-mutation carriers (NMCs) and 34 mutation carriers (MCs) subdivided into 11 asymptomatic MCs (AMCs) and 23 symptomatic MCs (SMCs). All individuals belonged to the same family developing long QT syndrome type 1 (LQT1) via KCNQ1-A341V mutation. We found that complexity indexes computed over EMD-filtered QT variability differentiated AMCs from NMCs and detected the effect of beta-blocker therapy, while complexity indexes calculated over EMD-filtered HP variability separated AMCs from SMCs. The EMD-based filtering method enhanced features of the cardiovascular control that otherwise would have remained hidden by the dominant presence of noise and/or fast physiological variations, thus improving classification in LQT1.http://www.mdpi.com/1099-4300/16/9/4839Publisher's versio

    Intelligent Biosignal Analysis Methods

    Get PDF
    This book describes recent efforts in improving intelligent systems for automatic biosignal analysis. It focuses on machine learning and deep learning methods used for classification of different organism states and disorders based on biomedical signals such as EEG, ECG, HRV, and others

    P Wave Detection in Pathological ECG Signals

    Get PDF
    Důležitou součástí hodnocení elektrokardiogramu (EKG) a následné detekce srdečních patologií, zejména v dlouhodobém monitorování, je detekce vln P. Výsledky detekce vln P umožňují získat ze záznamu EKG více informací o srdeční činnosti. Podle správně detekovaných pozic vln P je možné detekovat a odlišit patologie, které současné programy používané v medicínské praxi identifikovat neumožňují (např. atrioventrikulární blok 1., 2. a 3. stupně, cestující pacemaker, Wolffův-Parkinsonův-Whiteův syndrom). Tato dizertační práce představuje novou metodu detekce vln P v záznamech EKG během fyziologické a zejména patologické srdeční činnosti. Metoda je založena na fázorové transformaci, inovativních pravidlech detekce a identifikaci možných patologií zpřesňující detekci vln P. Dalším důležitým výsledkem práce je vytvoření dvou veřejně dostupných databází záznamů EKG s obsahem patologií a anotovanými vlnami P. Dizertační práce je rozdělena na teoretickou část a soubor publikací představující příspěvek autora v oblasti detekce vlny P.Accurate software for the P wave detection, mainly in long-term monitoring, is an important part of electrocardiogram (ECG) evaluation and subsequent cardiac pathological events detection. The results of P wave detection allow us to obtain more information from the ECG records. According to the correct P wave detection, it is possible to detect and distinguish cardiac pathologies which are nowadays automatically undetectable by commonly used software in medical practice (events e.g. atrioventricular block 1st, 2nd and 3rd degree, WPW syndrome, wandering pacemaker, etc.). This thesis introduces a new method for P wave detection in ECG signals during both physiological and pathological heart function. This novel method is based on a phasor transform, innovative rules, and identification of possible pathologies that improve P wave detection. An equally important part of the work is the creation of two publicly available databases of physiological and pathological ECG records with annotated P waves. The dissertation is divided into theoretical analysis and a set of publications representing the contribution of the author in the area of P wave detection.

    Data-driven methods for analyzing ballistocardiograms in longitudinal cardiovascular monitoring

    Get PDF
    Cardiovascular disease (CVD) is the leading cause of death in the US; about 48% of American adults have one or more types of CVD. The importance of continuous monitoring of the older population, for early detection of changes in health conditions, has been shown in the literature, as the key to a successful clinical intervention. We have been investigating environmentally-embedded in-home networks of non-invasive sensing modalities. This dissertation concentrates on the signal processing techniques required for the robust extraction of morphological features from the ballistocardiographs (BCG), and machine learning approaches to utilize these features in non-invasive monitoring of cardiovascular conditions. At first, enhancements in the time domain detection of the cardiac cycle are addressed due to its importance in the estimation of heart rate variability (HRV) and sleep stages. The proposed enhancements in the energy-based algorithm for BCG beat detection have shown at least 50% improvement in the root mean square error (RMSE) of the beat to beat heart rate estimations compared to the reference estimations from the electrocardiogram (ECG) R to R intervals. These results are still subject to some errors, primarily due to the contamination of noise and motion artifacts caused by floor vibration, unconstrained subject movements, or even the respiratory activities. Aging, diseases, breathing, and sleep disorders can also affect the quality of estimation as they slightly modify the morphology of the BCG waveform.Includes bibliographical reference

    Assessing Variability of EEG and ECG/HRV Time Series Signals Using a Variety of Non-Linear Methods

    Get PDF
    Time series signals, such as Electroencephalogram (EEG) and Electrocardiogram (ECG) represent the complex dynamic behaviours of biological systems. The analysis of these signals using variety of nonlinear methods is essential for understanding variability within EEG and ECG, which potentially could help unveiling hidden patterns related to underlying physiological mechanisms. EEG is a time varying signal, and electrodes for recording EEG at different positions on the scalp give different time varying signals. There might be correlation between these signals. It is important to know the correlation between EEG signals because it might tell whether or not brain activities from different areas are related. EEG and ECG might be related to each other because both of them are generated from one co-ordinately working body. Investigating this relationship is of interest because it may reveal information about the correlation between EEG and ECG signals. This thesis is about assessing variability of time series data, EEG and ECG, using variety of nonlinear measures. Although other research has looked into the correlation between EEGs using a limited number of electrodes and a limited number of combinations of electrode pairs, no research has investigated the correlation between EEG signals and distance between electrodes. Furthermore, no one has compared the correlation performance for participants with and without medical conditions. In my research, I have filled up these gaps by using a full range of electrodes and all possible combinations of electrode pairs analysed in Time Domain (TD). Cross-Correlation method is calculated on the processed EEG signals for different number unique electrode pairs from each datasets. In order to obtain the distance in centimetres (cm) between electrodes, a measuring tape was used. For most of our participants the head circumference range was 54-58cm, for which a medium-sized I have discovered that the correlation between EEG signals measured through electrodes is linearly dependent on the physical distance (straight-line) distance between them for datasets without medical condition, but not for datasets with medical conditions. Some research has investigated correlation between EEG and Heart Rate Variability (HRV) within limited brain areas and demonstrated the existence of correlation between EEG and HRV. But no research has indicated whether or not the correlation changes with brain area. Although Wavelet Transformations (WT) have been performed on time series data including EEG and HRV signals to extract certain features respectively by other research, so far correlation between WT signals of EEG and HRV has not been analysed. My research covers these gaps by conducting a thorough investigation of all electrodes on the human scalp in Frequency Domain (FD) as well as TD. For the reason of different sample rates of EEG and HRV, two different approaches (named as Method 1 and Method 2) are utilised to segment EEG signals and to calculate Pearson’s Correlation Coefficient for each of the EEG frequencies with each of the HRV frequencies in FD. I have demonstrated that EEG at the front area of the brain has a stronger correlation with HRV than that at the other area in a frequency domain. These findings are independent of both participants and brain hemispheres. Sample Entropy (SE) is used to predict complexity of time series data. Recent research has proposed new calculation methods for SE, aiming to improve the accuracy. To my knowledge, no one has attempted to reduce the computational time of SE calculation. I have developed a new calculation method for time series complexity which could improve computational time significantly in the context of calculating a correlation between EEG and HRV. The results have a parsimonious outcome of SE calculation by exploiting a new method of SE implementation. In addition, it is found that the electrical activity in the frontal lobe of the brain appears to be correlated with the HRV in a time domain. Time series analysis method has been utilised to study complex systems that appear ubiquitous in nature, but limited to certain dynamic systems (e.g. analysing variables affecting stock values). In this thesis, I have also investigated the nature of the dynamic system of HRV. I have disclosed that Embedding Dimension could unveil two variables that determined HRV

    The Application of Computer Techniques to ECG Interpretation

    Get PDF
    This book presents some of the latest available information on automated ECG analysis written by many of the leading researchers in the field. It contains a historical introduction, an outline of the latest international standards for signal processing and communications and then an exciting variety of studies on electrophysiological modelling, ECG Imaging, artificial intelligence applied to resting and ambulatory ECGs, body surface mapping, big data in ECG based prediction, enhanced reliability of patient monitoring, and atrial abnormalities on the ECG. It provides an extremely valuable contribution to the field

    Analysis of Ventricular Depolarisation and Repolarisation Using Registration and Machine Learning

    Get PDF
    Our understanding of cardiac diseases has greatly advanced since the advent of electrocardiography (ECG). With the increasing influx of available data in recent times, significant research efforts have been put forth to automate the study and detection of cardiac conditions. Naturally, the focus has progressed toward studying dynamic changes in ventricular depolarisation and repolarisation across serial recordings - as complex beat-to-beat changes in morphology manifest over time. Manual extraction of diagnostic and prognostic markers is a laborious task. Hence, automated and accurate methods are required to extract markers for the study of ventricular lability and detection of common diseases, such as myocardial ischemia and myocardial infarction. The aim of this thesis is to improve automated marker extraction and detection of diseases for the study of ventricular depolarisation and repolarisation lability in ECG. As such, two novel template adaptation methods capable of capturing complex beat-to-beat morphological changes are proposed for three-dimensional and two-dimensional data, respectively. The proposed three-dimensional template adaptation method provides an inhomogeneous method for transforming template vectorcardiogram (VCG) by exploiting registrationinspired parametrisation and an efficient kernel ridge regression formulation. Analysis across simulated data and clinical myocardial infarction data demonstrates state-of-the-art results. The two-dimensional template adaptation method draws from traditional registrationbased techniques and treats the ECG as a two-dimensional point set problem. Validation against previously employed simulated data and a gold-standard annotated clinical database demonstrate the highest level of performance. Subsequently, frameworks employing the proposed template adaptation techniques are developed for the automated detection of ischemic beats and myocardial infarction. Furthermore, a small study analysing ventricular repolarisation variability (VRV) in non-ischemic cardiomyopathy (CM) is considered, utilising markers of cardiac lability proposed in the development of the three-dimensional template adaptation system. In summary, this thesis highlights the necessity for custom template adaptation methods for the accurate measurement of beat-to-beat variability in cardiac data. Two novel stateof- the-art methods are proposed and extended to study myocardial ischemia, myocardial infarction and non-ischemic CM.Thesis (Ph.D.) -- University of Adelaide, School of Electrical and Electronic Engineering, 202

    Novel Low Complexity Biomedical Signal Processing Techniques for Online Applications

    Get PDF
    Biomedical signal processing has become a very active domain of research nowadays. With the advent of portable monitoring devices, from accelerometer-enabled bracelets and smart-phones to more advanced vital sign tracking body area networks, this field has been receiving unprecedented attention. Indeed, portable health monitoring can help uncover the underlying dynamics of human health in a way that has not been possible before. Several challenges have emerged however, as these devices present key differences in terms of signal acquisition and processing in comparison with conventional methods. Hardware constraints such as processing power and limited battery capacity make most established techniques unsuitable and therefore, the need for low-complexity yet robust signal processing methods has appeared. Another issue that needs to be addressed is the quality of the signals captured by these devices. Unlike in clinical scenarios, in portable health monitoring subjects are constantly performing their daily activities. Moreover, signals maybe captured from unconventional locations and subsequently, be prone to perturbations. In order to obtain reliable measures from these monitoring devices, one needs to acquire dependable signal quality measures, to avoid false alarms. Indeed, hardware limitations and low-quality signals can greatly influence the performance of portable monitoring devices. Nevertheless, most devices offer simultaneous acquisition of multiple physiological parameters, such as electrocardiogram (ECG) and photoplethysmogram (PPG). Through multi-modal signal processing the overall performance can be improved, for instance by deriving parameters such as heart rate estimation from the most reliable and uncontaminated source. This thesis is therefore, dedicated to propose novel low-complexity biomedical processing techniques for real-time/online applications. Throughout this dissertation, several bio-signals such as the ECG, PPG, and electroencephalogram (EEG) are investigated. %There is an emphasis on ECG processing techniques, as most of the bio-signals recorded today reflect information about the heart. The main contribution of this dissertation consists in two signal processing techniques: 1) a novel ECG QRS-complex detection and delineation technique, and 2) a short-term event extraction technique for biomedical signals. The former is based on a processing technique called mathematical morphology (MM), and adaptively uses subject QRS-complex amplitude- and morphological attributes for a robust detection and delineation. This method is generalized to intra-cardiac electrograms for atrial activation detection during atrial fibrillation. The second method, called the Relative-Energy algorithm, uses short- and long-term signal energies to highlight events of interest and discard unwanted activities. Collectively, the results obtained by these methods suggest that while presenting low-computational costs, they can efficiently and robustly extract biomedical events of interest. Using the relative energy algorithm, a continuous non-binary ECG signal quality index is presented. The ECG quality is determined by creating a cleaned-up version of the input ECG and calculating the correlation coefficient between the cleaned-up and the original ECG. The proposed quality index is fast and can be implemented online, making it suitable for portable monitoring scenarios

    Spatiotemporal brain dynamics induced by propofol and ketamine in humans

    Get PDF
    Human brain dynamics are radically altered under the influence of anaesthetics. However, despite their widespread clinical use, the whole-brain mechanisms by which anaesthetics alter consciousness are still not fully understood and clinical translation of existing insights is limited. This thesis presents several lines of investigation aimed to improve our understanding of spatiotemporal brain states under the anaesthetics propofol and ketamine. First, slow-wave activity saturation (SWAS) was studied across the brain and in relation to existing depth of anaesthesia markers. Local propofol concentration needed to achieve SWAS in healthy volunteers correlated with GABA-A receptor density (Spearman ρ=-0.69, P=0.0018), providing more evidence for the importance of the neurophysiological state of SWAS. The average Bispectral Index at SWAS across volunteers was 49±4, but its value varied significantly over time. Second, relevant cortico-cardiac interactions were studied. A slow propofol infusion increased heart rate in a dose-dependent manner (increase of +4.2±1.5 bpm / (μg ml-1), P<0.001). Individual cortical slow waves were coupled to the heartbeat (P<0.001), with heartbeat incidence peaking about 450ms before slow-wave onset. A ketamine case study showed decreased amplitude of heartbeat-evoked potentials, suggesting impaired interoceptive signalling may have a part in dissociative phenomenology. Third, novel methodology was developed, validated, and applied throughout the thesis. Iterated Masking Empirical Mode Decomposition was used to identify three types of low-frequency propofol waves with different spatiotemporal maps and dose-responses. Hidden Markov Modelling of propofol showed a shift to anterior alpha states and a reduced switching rate (P<0.01); with ketamine states exhibiting low alpha power and decreased connectivity became more prominent (P<0.001). Fourth, the potential of translating electroencephalographic markers from high- to low- density montages was studied. Posterior montages were best at capturing the reduced state switching under propofol. A patient study of antidepressant ketamine treatment demonstrated reduced temporal lobe alpha and theta power were associated with dissociation (P=0.0109)

    Wearable and BAN Sensors for Physical Rehabilitation and eHealth Architectures

    Get PDF
    The demographic shift of the population towards an increase in the number of elderly citizens, together with the sedentary lifestyle we are adopting, is reflected in the increasingly debilitated physical health of the population. The resulting physical impairments require rehabilitation therapies which may be assisted by the use of wearable sensors or body area network sensors (BANs). The use of novel technology for medical therapies can also contribute to reducing the costs in healthcare systems and decrease patient overflow in medical centers. Sensors are the primary enablers of any wearable medical device, with a central role in eHealth architectures. The accuracy of the acquired data depends on the sensors; hence, when considering wearable and BAN sensing integration, they must be proven to be accurate and reliable solutions. This book is a collection of works focusing on the current state-of-the-art of BANs and wearable sensing devices for physical rehabilitation of impaired or debilitated citizens. The manuscripts that compose this book report on the advances in the research related to different sensing technologies (optical or electronic) and body area network sensors (BANs), their design and implementation, advanced signal processing techniques, and the application of these technologies in areas such as physical rehabilitation, robotics, medical diagnostics, and therapy
    corecore