236 research outputs found
Computational Analysis of Fundus Images: Rule-Based and Scale-Space Models
Fundus images are one of the most important imaging examinations in modern ophthalmology
because they are simple, inexpensive and, above all, noninvasive.
Nowadays, the acquisition and
storage of highresolution
fundus images is relatively easy and fast. Therefore, fundus imaging
has become a fundamental investigation in retinal lesion detection, ocular health monitoring and
screening programmes. Given the large volume and clinical complexity associated with these images,
their analysis and interpretation by trained clinicians becomes a timeconsuming
task and is
prone to human error. Therefore, there is a growing interest in developing automated approaches
that are affordable and have high sensitivity and specificity. These automated approaches need to
be robust if they are to be used in the general population to diagnose and track retinal diseases. To
be effective, the automated systems must be able to recognize normal structures and distinguish
them from pathological clinical manifestations.
The main objective of the research leading to this thesis was to develop automated systems capable
of recognizing and segmenting retinal anatomical structures and retinal pathological clinical
manifestations associated with the most common retinal diseases. In particular, these automated
algorithms were developed on the premise of robustness and efficiency to deal with the difficulties
and complexity inherent in these images. Four objectives were considered in the analysis of
fundus images. Segmentation of exudates, localization of the optic disc, detection of the midline
of blood vessels, segmentation of the vascular network and detection of microaneurysms.
In addition, we also evaluated the detection of diabetic retinopathy on fundus images using the
microaneurysm detection method. An overview of the state of the art is presented to compare the
performance of the developed approaches with the main methods described in the literature for
each of the previously described objectives. To facilitate the comparison of methods, the state of
the art has been divided into rulebased
methods and machine learningbased
methods.
In the research reported in this paper, rulebased
methods based on image processing methods
were preferred over machine learningbased
methods. In particular, scalespace
methods proved
to be effective in achieving the set goals.
Two different approaches to exudate segmentation were developed. The first approach is based on
scalespace
curvature in combination with the local maximum of a scalespace
blob detector and
dynamic thresholds. The second approach is based on the analysis of the distribution function of
the maximum values of the noise map in combination with morphological operators and adaptive
thresholds. Both approaches perform a correct segmentation of the exudates and cope well with
the uneven illumination and contrast variations in the fundus images.
Optic disc localization was achieved using a new technique called cumulative sum fields, which was
combined with a vascular enhancement method. The algorithm proved to be reliable and efficient,
especially for pathological images. The robustness of the method was tested on 8 datasets.
The detection of the midline of the blood vessels was achieved using a modified corner detector
in combination with binary philtres and dynamic thresholding. Segmentation of the vascular network
was achieved using a new scalespace
blood vessels enhancement method. The developed
methods have proven effective in detecting the midline of blood vessels and segmenting vascular
networks.
The microaneurysm detection method relies on a scalespace
microaneurysm detection and labelling
system. A new approach based on the neighbourhood of the microaneurysms was used
for labelling. Microaneurysm detection enabled the assessment of diabetic retinopathy detection.
The microaneurysm detection method proved to be competitive with other methods, especially with highresolution
images. Diabetic retinopathy detection with the developed microaneurysm
detection method showed similar performance to other methods and human experts.
The results of this work show that it is possible to develop reliable and robust scalespace
methods
that can detect various anatomical structures and pathological features of the retina. Furthermore,
the results obtained in this work show that although recent research has focused on machine learning
methods, scalespace
methods can achieve very competitive results and typically have greater
independence from image acquisition. The methods developed in this work may also be relevant
for the future definition of new descriptors and features that can significantly improve the results
of automated methods.As imagens do fundo do olho são hoje um dos principais exames imagiológicos da oftalmologia
moderna, pela sua simplicidade, baixo custo e acima de tudo pelo seu carácter nãoinvasivo.
A
aquisição e armazenamento de imagens do fundo do olho com alta resolução é também relativamente
simples e rápida. Desta forma, as imagens do fundo do olho são um exame fundamental
na identificação de alterações retinianas, monitorização da saúde ocular, e em programas de rastreio.
Considerando o elevado volume e complexidade clínica associada a estas imagens, a análise
e interpretação das mesmas por clínicos treinados tornase
uma tarefa morosa e propensa a erros
humanos. Assim, há um interesse crescente no desenvolvimento de abordagens automatizadas,
acessíveis em custo, e com uma alta sensibilidade e especificidade. Estas devem ser robustas para
serem aplicadas à população em geral no diagnóstico e seguimento de doenças retinianas. Para
serem eficazes, os sistemas de análise têm que conseguir detetar e distinguir estruturas normais
de sinais patológicos.
O objetivo principal da investigação que levou a esta tese de doutoramento é o desenvolvimento
de sistemas automáticos capazes de detetar e segmentar as estruturas anatómicas da retina, e os
sinais patológicos retinianos associados às doenças retinianas mais comuns. Em particular, estes
algoritmos automatizados foram desenvolvidos segundo as premissas de robustez e eficácia para
lidar com as dificuldades e complexidades inerentes a estas imagens.
Foram considerados quatro objetivos de análise de imagens do fundo do olho. São estes, a segmentação
de exsudados, a localização do disco ótico, a deteção da linha central venosa dos vasos
sanguíneos e segmentação da rede vascular, e a deteção de microaneurismas. De acrescentar que
usando o método de deteção de microaneurismas, avaliouse
também a capacidade de deteção da
retinopatia diabética em imagens do fundo do olho.
Para comparar o desempenho das metodologias desenvolvidas neste trabalho, foi realizado um
levantamento do estado da arte, onde foram considerados os métodos mais relevantes descritos na
literatura para cada um dos objetivos descritos anteriormente. Para facilitar a comparação entre
métodos, o estado da arte foi dividido em metodologias de processamento de imagem e baseadas
em aprendizagem máquina.
Optouse
no trabalho de investigação desenvolvido pela utilização de metodologias de análise espacial
de imagem em detrimento de metodologias baseadas em aprendizagem máquina. Em particular,
as metodologias baseadas no espaço de escalas mostraram ser efetivas na obtenção dos
objetivos estabelecidos.
Para a segmentação de exsudados foram usadas duas abordagens distintas. A primeira abordagem
baseiase
na curvatura em espaço de escalas em conjunto com a resposta máxima local de um detetor
de manchas em espaço de escalas e limiares dinâmicos. A segunda abordagem baseiase
na
análise do mapa de distribuição de ruído em conjunto com operadores morfológicos e limiares
adaptativos. Ambas as abordagens fazem uma segmentação dos exsudados de elevada precisão,
além de lidarem eficazmente com a iluminação nãouniforme
e a variação de contraste presente
nas imagens do fundo do olho. A localização do disco ótico foi conseguida com uma nova técnica
designada por campos de soma acumulativos, combinada com métodos de melhoramento da rede
vascular. O algoritmo revela ser fiável e eficiente, particularmente em imagens patológicas. A robustez
do método foi verificada pela sua avaliação em oito bases de dados. A deteção da linha central
dos vasos sanguíneos foi obtida através de um detetor de cantos modificado em conjunto com
filtros binários e limiares dinâmicos. A segmentação da rede vascular foi conseguida com um novo
método de melhoramento de vasos sanguíneos em espaço de escalas. Os métodos desenvolvidos mostraram ser eficazes na deteção da linha central dos vasos sanguíneos e na segmentação da rede
vascular. Finalmente, o método para a deteção de microaneurismas assenta num formalismo de
espaço de escalas na deteção e na rotulagem dos microaneurismas. Para a rotulagem foi utilizada
uma nova abordagem da vizinhança dos candidatos a microaneurismas. A deteção de microaneurismas
permitiu avaliar também a deteção da retinopatia diabética. O método para a deteção
de microaneurismas mostrou ser competitivo quando comparado com outros métodos, em particular
em imagens de alta resolução. A deteção da retinopatia diabética exibiu um desempenho
semelhante a outros métodos e a especialistas humanos.
Os trabalhos descritos nesta tese mostram ser possível desenvolver uma abordagem fiável e robusta
em espaço de escalas capaz de detetar diferentes estruturas anatómicas e sinais patológicos
da retina.
Além disso, os resultados obtidos mostram que apesar de a pesquisa mais recente concentrarse
em metodologias de aprendizagem máquina, as metodologias de análise espacial apresentam
resultados muito competitivos e tipicamente independentes do equipamento de aquisição das imagens.
As metodologias desenvolvidas nesta tese podem ser importantes na definição de novos
descritores e características, que podem melhorar significativamente o resultado de métodos automatizados
Automated microaneurysm detection algorithms applied to diabetic retinopathy retinal images
Diabetic retinopathy is the commonest cause of blindness in working age people. It is characterised and graded by the development of retinal microaneurysms, haemorrhages and exudates. The damage caused by diabetic retinopathy can be prevented if it is treated in its early stages. Therefore, automated early detection can limit the severity of the disease, improve the follow-up management of diabetic patients and assist ophthalmologists in investigating and treating the disease more efficiently. This review focuses on microaneurysm detection as the earliest clinically localised characteristic of diabetic retinopathy, a frequently observed complication in both Type 1 and Type 2 diabetes. Algorithms used for microaneurysm detection from retinal images are reviewed. A number of features used to extract microaneurysm are summarised. Furthermore, a comparative analysis of reported methods used to automatically detect microaneurysms is presented and discussed. The performance of methods and their complexity are also discussed
Detection and Classification of Diabetic Retinopathy Pathologies in Fundus Images
Diabetic Retinopathy (DR) is a disease that affects up to 80% of diabetics around the world. It is the second greatest cause of blindness in the Western world, and one of the leading causes of blindness in the U.S. Many studies have demonstrated that early treatment can reduce the number of sight-threatening DR cases, mitigating the medical and economic impact of the disease. Accurate, early detection of eye disease is important because of its potential to reduce rates of blindness worldwide. Retinal photography for DR has been promoted for decades for its utility in both disease screening and clinical research studies. In recent years, several research centers have presented systems to detect pathology in retinal images. However, these approaches apply specialized algorithms to detect specific types of lesion in the retina. In order to detect multiple lesions, these systems generally implement multiple algorithms. Furthermore, some of these studies evaluate their algorithms on a single dataset, thus avoiding potential problems associated with the differences in fundus imaging devices, such as camera resolution. These methodologies primarily employ bottom-up approaches, in which the accurate segmentation of all the lesions in the retina is the basis for correct determination. A disadvantage of bottom-up approaches is that they rely on the accurate segmentation of all lesions in order to measure performance. On the other hand, top-down approaches do not depend on the segmentation of specific lesions. Thus, top-down methods can potentially detect abnormalities not explicitly used in their training phase. A disadvantage of these methods is that they cannot identify specific pathologies and require large datasets to build their training models. In this dissertation, I merged the advantages of the top-down and bottom-up approaches to detect DR with high accuracy. First, I developed an algorithm based on a top-down approach to detect abnormalities in the retina due to DR. By doing so, I was able to evaluate DR pathologies other than microaneurysms and exudates, which are the main focus of most current approaches. In addition, I demonstrated good generalization capacity of this algorithm by applying it to other eye diseases, such as age-related macular degeneration. Due to the fact that high accuracy is required for sight-threatening conditions, I developed two bottom-up approaches, since it has been proven that bottom-up approaches produce more accurate results than top-down approaches for particular structures. Consequently, I developed an algorithm to detect exudates in the macula. The presence of this pathology is considered to be a surrogate for clinical significant macular edema (CSME), a sight-threatening condition of DR. The analysis of the optic disc is usually not taken into account in DR screening systems. However, there is a pathology called neovascularization that is present in advanced stages of DR, making its detection of crucial clinical importance. In order to address this problem, I developed an algorithm to detect neovascularization in the optic disc. These algorithms are based on amplitude-modulation and frequency-modulation (AM-FM) representations, morphological image processing methods, and classification algorithms. The methods were tested on a diverse set of large databases and are considered to be the state-of the art in this field
Evaluation of fractal dimension effectiveness for damage detection in retinal background
[EN] This work investigates the characterization of bright lesions in retinal fundus images using texture analysis techniques. Exudates and drusen are evidences of retinal damage in diabetic retinopathy (DR) and age-related macular degeneration (AMD) respectively. An automatic detection of pathological tissues could make possible an early detection of these diseases. In this work, fractal analysis is explored in order to discriminate between pathological and healthy retinal texture. After a deep preprocessing step, in which spatial and colour normalization are performed, the fractal dimension is extracted locally by computing the Hurst exponent (H) along different directions. The greyscale image is described by the increments of the fractional Brownian motion model and the H parameter is computed by linear regression in the frequency domain. The ability of fractal dimension to detect pathological tissues is demonstrated using a home-made system, based on fractal analysis and Support Vector Machine, able to achieve around a 70% and 83% of accuracy in E-OPHTHA and DIARETDB1 public databases respectively. In a second experiment, the fractal descriptor is combined with texture information, extracted by the Local Binary Patterns, improving the bright lesion detection. Accuracy, sensitivity and specificity values higher than 89%, 80% and 90% respectively suggest that the method presented in this paper is a robust algorithm for describing retina texture and can be useful in the automatic detection of DR and AMD.This paper was supported by the European Union's Horizon 2020 research and innovation programme under the Project GALAHAD [H2020-ICT-2016-2017, 732613]. In addition, this work was partially funded by the Ministerio de Economia y Competitividad of Spain, Project SICAP [DPI2016-77869-C2-1-R]. The work of Adrian Colomer has been supported by the Spanish Government under a FPI Grant [BES-2014-067889]. We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this research.Colomer, A.; Naranjo Ornedo, V.; Janvier, T.; Mossi García, JM. (2018). Evaluation of fractal dimension effectiveness for damage detection in retinal background. Journal of Computational and Applied Mathematics. 337:341-353. https://doi.org/10.1016/j.cam.2018.01.005S34135333
Automated retinal analysis
Diabetes is a chronic disease affecting over 2% of the population in the UK [1]. Long-term complications of diabetes can affect many different systems of the body including the retina of the eye. In the retina, diabetes can lead to a disease called diabetic retinopathy, one of the leading causes of blindness in the working population of industrialised countries. The risk of visual loss from diabetic retinopathy can be reduced if treatment is given at the onset of sight-threatening retinopathy. To detect early indicators of the disease, the UK National Screening Committee have recommended that diabetic patients should receive annual screening by digital colour fundal photography [2]. Manually grading retinal images is a subjective and costly process requiring highly skilled staff. This thesis describes an automated diagnostic system based oil image processing and neural network techniques, which analyses digital fundus images so that early signs of sight threatening retinopathy can be identified. Within retinal analysis this research has concentrated on the development of four algorithms: optic nerve head segmentation, lesion segmentation, image quality assessment and vessel width measurements. This research amalgamated these four algorithms with two existing techniques to form an integrated diagnostic system. The diagnostic system when used as a 'pre-filtering' tool successfully reduced the number of images requiring human grading by 74.3%: this was achieved by identifying and excluding images without sight threatening maculopathy from manual screening
Dual-Branch U-Net Architecture for Retinal Lesions Segmentation on Fundus Image
Deep learning has found widespread application in diabetic retinopathy (DR) screening, primarily for lesion detection. However, this approach encounters challenges such as information loss due to convolutional operations, shape uncertainty, and the high similarity between different lesions types. These factors collectively hinder the accurate segmentation of lesions. In this research paper, we introduce a novel dual-branch U-Net architecture, referred to as Dual-Branch (DB)-U-Net, tailored to address the intricacies of small-scale lesion segmentation. Our approach involves two branches: one employs a U-Net to capture the shared characteristics of lesions, while the other utilizes a modified U-Net, known as U2Net, equipped with two decoders that share a common encoder. U2Net is responsible for generating probability maps for lesion segmentation as well as corresponding boundary segmentation. DB U-Net combines the outputs of U2Net and U-Net as a dual branch, concatenating their segmentation maps to produce the final result. To mitigate the challenge of imbalanced data, we employ the Dice loss as a loss function. We evaluate the effectiveness of our approach on publicly available datasets, including DDR, IDRiD, and E-Ophtha. Our results demonstrate that DB U-Net achieves AUPR values of 0.5254 and 0.7297 for Microaneurysms and soft exudates segmentation, respectively, on the IDRiD dataset. These results outperform other models, highlighting the potential clinical utility of our method in identifying retinal lesions from retinal fundus images
Deep learning for diabetic retinopathy detection and classification based on fundus images: A review.
Diabetic Retinopathy is a retina disease caused by diabetes mellitus and it is the leading cause of blindness globally. Early detection and treatment are necessary in order to delay or avoid vision deterioration and vision loss. To that end, many artificial-intelligence-powered methods have been proposed by the research community for the detection and classification of diabetic retinopathy on fundus retina images. This review article provides a thorough analysis of the use of deep learning methods at the various steps of the diabetic retinopathy detection pipeline based on fundus images. We discuss several aspects of that pipeline, ranging from the datasets that are widely used by the research community, the preprocessing techniques employed and how these accelerate and improve the models' performance, to the development of such deep learning models for the diagnosis and grading of the disease as well as the localization of the disease's lesions. We also discuss certain models that have been applied in real clinical settings. Finally, we conclude with some important insights and provide future research directions
Automated Retinal Lesion Detection via Image Saliency Analysis
Background and objective:The detection of abnormalities such as lesions or leakage from retinal images is an important health informatics task for automated early diagnosis of diabetic and malarial retinopathy or other eye diseases, in order to prevent blindness and common systematic conditions. In this work, we propose a novel retinal lesion detection method by adapting the concepts of saliency. Methods :Retinal images are firstly segmented as superpixels, two new saliency feature representations: uniqueness and compactness, are then derived to represent the superpixels. The pixel level saliency is then estimated from these superpixel saliency values via a bilateral filter. These extracted saliency features form a matrix for low-rank analysis to achieve saliency detection. The precise contour of a lesion is finally extracted from the generated saliency map after removing confounding structures such as blood vessels, the optic disc, and the fovea. The main novelty of this method is that it is an effective tool for detecting different abnormalities at pixel-level from different modalities of retinal images, without the need to tune parameters. Results:To evaluate its effectiveness, we have applied our method to seven public datasets of diabetic and malarial retinopathy with four different types of lesions: exudate, hemorrhage, microaneurysms, and leakage. The evaluation was undertaken at pixel-level, lesion-level, or image-level according to ground truth availability in these datasets. Conclusions:The experimental results show that the proposed method outperforms existing state-of-the-art ones in applicability, effectiveness, and accuracy
- …