1,813 research outputs found

    Optimization Based Partitioning Selection for Improved Contaminant Detection Performance

    Get PDF
    Indoor Air Quality monitoring is an essential ingredient of intelligent buildings. The release of various airborne contaminants into the buildings, compromises the health and safety of occupants. Therefore, early contaminant detection is of paramount importance for the timely activation of proper contingency plans in order to minimize the impact of contaminants on occupants health. The objective of this work is to enhance the performance of a distributed contaminant detection methodology, in terms of the minimum detectable contaminant release rates, by considering the joint problem of partitioning selection and observer gain design. Towards this direction, a detectability analysis is performed to derive appropriate conditions for the minimum guaranteed detectable contaminant release rate for specific partitioning configuration and observer gains. The derived detectability conditions are then exploited to formulate and solve an optimization problem for jointly selecting the partitioning configuration and observer gains that yield the best contaminant detection performance

    Modeling, Monitoring and Fault Diagnosis of Spacecraft Air Contaminants

    Get PDF
    Control of air contaminants is a crucial factor in the safety considerations of crewed space flight. Indoor air quality needs to be closely monitored during long range missions such as a Mars mission, and also on large complex space structures such as the International Space Station. This work mainly pertains to the detection and simulation of air contaminants in the space station, though much of the work is easily extended to buildings, and issues of ventilation systems. Here we propose a method with which to track the presence of contaminants using an accurate physical model, and also develop a robust procedure that would raise alarms when certain tolerance levels are exceeded. A part of this research concerns the modeling of air flow inside a spacecraft, and the consequent dispersal pattern of contaminants. Our objective is to also monitor the contaminants on-line, so we develop a state estimation procedure that makes use of the measurements from a sensor system and determines an optimal estimate of the contamination in the system as a function of time and space. The real-time optimal estimates in turn are used to detect faults in the system and also offer diagnoses as to their sources. This work is concerned with the monitoring of air contaminants aboard future generation spacecraft and seeks to satisfy NASA's requirements as outlined in their Strategic Plan document (Technology Development Requirements, 1996)

    Virtual sensor of surface electromyography in a new extensive fault-tolerant classification system

    Get PDF
    A few prosthetic control systems in the scientific literature obtain pattern recognition algorithms adapted to changes that occur in the myoelectric signal over time and, frequently, such systems are not natural and intuitive. These are some of the several challenges for myoelectric prostheses for everyday use. The concept of the virtual sensor, which has as its fundamental objective to estimate unavailable measures based on other available measures, is being used in other fields of research. The virtual sensor technique applied to surface electromyography can help to minimize these problems, typically related to the degradation of the myoelectric signal that usually leads to a decrease in the classification accuracy of the movements characterized by computational intelligent systems. This paper presents a virtual sensor in a new extensive fault-tolerant classification system to maintain the classification accuracy after the occurrence of the following contaminants: ECG interference, electrode displacement, movement artifacts, power line interference, and saturation. The Time-Varying Autoregressive Moving Average (TVARMA) and Time-Varying Kalman filter (TVK) models are compared to define the most robust model for the virtual sensor. Results of movement classification were presented comparing the usual classification techniques with the method of the degraded signal replacement and classifier retraining The experimental results were evaluated for these five noise types in 16 surface electromyography (sEMG) channel degradation case studies. The proposed system without using classifier retraining techniques recovered of mean classification accuracy was of 4% to 38% for electrode displacement, movement artifacts, and saturation noise. The best mean classification considering all signal contaminants and channel combinations evaluated was the classification using the retraining method, replacing the degraded channel by the virtual sensor TVARMA model. This method recovered the classification accuracy after the degradations, reaching an average of 5.7% below the classification of the clean signal, that is the signal without the contaminants or the original signal. Moreover, the proposed intelligent technique minimizes the impact of the motion classification caused by signal contamination related to degrading events over time. There are improvements in the virtual sensor model and in the algorithm optimization that need further development to provide an increase the clinical application of myoelectric prostheses but already presents robust results to enable research with virtual sensors on biological signs with stochastic behavior

    Atmospheric Air Pollution and Monitoring

    Get PDF
    Indoor air quality (IAQ) is an important aspect in building design due to its effect on human health and wellbeing. Generally, people spend about 90% of their time indoors where they are exposed to chemicals, particulate matters, biological contaminants and possibly carcinogens. In particular, the air quality at hospitals carries with it risks for serious health consequences for medical staff as well as patients and visitors. This book is a study of atmospheric air pollution and presents ways we can reduce its impacts on human health. It discusses tools for measuring IAQ as well as analyzes IAQ in closed buildings. It is an important documentation of air quality and its impact on human health

    Validation Techniques for Sensor Data in Mobile Health Applications

    Get PDF
    Mobile applications have become amust in every user’s smart device, andmany of these applications make use of the device sensors’ to achieve its goal. Nevertheless, it remains fairly unknown to the user to which extent the data the applications use can be relied upon and, therefore, to which extent the output of a given application is trustworthy or not. To help developers and researchers and to provide a common ground of data validation algorithms and techniques, this paper presents a review of the most commonly used data validation algorithms, along with its usage scenarios, and proposes a classification for these algorithms. This paper also discusses the process of achieving statistical significance and trust for the desired output.Portuguese Foundation for Science and Technology UID/EEA/50008/2013COST Action Architectures, Algorithms and Protocols for Enhanced Living Environments (AAPELE) IC130

    Intelligent urban water infrastructure management

    Get PDF
    Copyright © 2013 Indian Institute of ScienceUrban population growth together with other pressures, such as climate change, create enormous challenges to provision of urban infrastructure services, including gas, electricity, transport, water, etc. Smartgrid technology is viewed as the way forward to ensure that infrastructure networks are fl exible, accessible, reliable and economical. “Intelligent water networks” take advantage of the latest information and communication technologies to gather and act on information to minimise waste and deliver more sustainable water services. The effective management of water distribution, urban drainage and sewerage infrastructure is likely to require increasingly sophisticated computational techniques to keep pace with the level of data that is collected from measurement instruments in the field. This paper describes two examples of intelligent systems developed to utilise this increasingly available real-time sensed information in the urban water environment. The first deals with the failure-management decision-support system for water distribution networks, NEPTUNE, that takes advantage of intelligent computational methods and tools applied to near real-time logger data providing pressures, flows and tank levels at selected points throughout the system. The second, called RAPIDS, deals with urban drainage systems and the utilisation of rainfall data to predict flooding of urban areas in near real-time. The two systems have the potential to provide early warning and scenario testing for decision makers within reasonable time, this being a key requirement of such systems. Computational methods that require hours or days to run will not be able to keep pace with fast-changing situations such as pipe bursts or manhole flooding and thus the systems developed are able to react in close to real time.Engineering and Physical Sciences Research CouncilUK Water Industry ResearchYorkshire Wate

    LC-MS based analysis of secondary metabolites from <i>Chaetomium</i> and <i>Stachybotrys</i> growth in indoor environments

    Get PDF

    NASA SBIR abstracts of 1990 phase 1 projects

    Get PDF
    The research objectives of the 280 projects placed under contract in the National Aeronautics and Space Administration (NASA) 1990 Small Business Innovation Research (SBIR) Phase 1 program are described. The basic document consists of edited, non-proprietary abstracts of the winning proposals submitted by small businesses in response to NASA's 1990 SBIR Phase 1 Program Solicitation. The abstracts are presented under the 15 technical topics within which Phase 1 proposals were solicited. Each project was assigned a sequential identifying number from 001 to 280, in order of its appearance in the body of the report. The document also includes Appendixes to provide additional information about the SBIR program and permit cross-reference in the 1990 Phase 1 projects by company name, location by state, principal investigator, NASA field center responsible for management of each project, and NASA contract number
    corecore