601 research outputs found

    Faults and unbalance forces in the switched reluctance machine

    Get PDF
    The paper identifies and analyzes a number of severe fault conditions that can occur in the switched reluctance machine, from the electrical and mechanical points of view. It is shown how the currents, torques, and forces may be estimated, and examples are included showing the possibility of large lateral forces on the rotor. The methods used for analysis include finite-element analysis, magnetic circuit models, and experiments on a small machine specially modified for the measurement of forces and magnetization characteristics when the rotor is off-center. Also described is a computer program (PC-SRD dynamic) which is used for simulating operation under fault conditions as well as normal conditions. The paper discusses various electrical configurations of windings and controller circuits, along with methods of fault detection and protective relaying. The paper attempts to cover several analytical and experimental aspects as well as methods of detection and protection

    Studies in Electrical Machines & Wind Turbines associated with developing Reliable Power Generation

    Get PDF
    The publications listed in date order in this document are offered for the Degree of Doctor of Science in Durham University and have been selected from the author’s full publication list. The papers in this thesis constitute a continuum of original work in fundamental and applied electrical science, spanning 30 years, deployed on real industrial problems, making a significant contribution to conventional and renewable energy power generation. This is the basis of a claim of high distinction, constituting an original and substantial contribution to engineering science

    Electrical and magnetic faults diagnosis in permanent magnet synchronous motors

    Get PDF
    Permanent magnet synchronous motors (PMSMs) are an alternative in critical applications where high-speed operation, compactness and high efficiency are required. In these applications it is highly desired to dispose of an on-line, reliable and cost-effective fault diagnosis method. Fault prediction and diagnosis allows increasing electric machines performance and raising their lifespan, thus reducing maintenance costs, while ensuring optimum reliability, safe operation and timely maintenance. Consequently this thesis is dedicated to the diagnosis of magnetic and electrical faults in PMSMs. As a first step, the behavior of a healthy machine is studied, and with this aim a new 2D finite element method (FEM) modelbased system for analyzing surface-mounted PSMSs with skewed rotor magnets is proposed. It is based on generating a geometric equivalent non-skewed permanent magnet distribution which accounts for the skewed distribution of the practical rotor, thus avoiding 3D geometries and greatly reducing the computational burden of the problem. To diagnose demagnetization faults, this thesis proposes an on-line methodology based on monitoring the zero-sequence voltage component (ZSVC). Attributes of the proposed method include simplicity, very low computational burden and high sensibility when compared with the well known stator currents analysis method. A simple expression of the ZSVC is deduced, which can be used as a fault indicator parameter. Furthermore, mechanical effects arising from demagnetization faults are studied. These effects are analyzed by means of FEM simulations and experimental tests based on direct measurements of the shaft trajectory through self-mixing interferometry. For that purpose two perpendicular laser diodes are used to measure displacements in both X and Y axes. Laser measurements proved that demagnetization faults may induce a quantifiable deviation of the rotor trajectory. In the case of electrical faults, this thesis studies the effects of resistive unbalance and stator winding inter-turn short-circuits in PMSMs and compares two methods for detecting and discriminating both faults. These methods are based on monitoring and analyzing the third harmonic component of the stator currents and the first harmonic of the ZSVC. Finally, the Vold-Kalman filtering order tracking algorithm is introduced and applied to extract selected harmonics related to magnetic and electrical faults when the machine operates under variable speed and different load levels. Furthermore, different fault indicators are proposed and their behavior is validated by means of experimental data. Both simulation and experimental results show the potential of the proposed methods to provide helpful and reliable data to carry out a simultaneous diagnosis of resistive unbalance and stator winding inter-turn faults

    Health Monitoring Techniques for High Availability Drives

    Get PDF
    The growing number and need for high availability drives in the modern world places high importance on reliability and operational availability. Part of the solution to the increased requirements on availability involves monitoring degradation associated with machine failure, diagnosing the mode of failure and predicting into the future to a possible time to failure. Broad multi-disciplinary knowledge is required to understand drive ageing and implement monitoring systems. This research reviews the failure modes associated with high availability drives, in particular with regards to low voltage random wound permanent magnet inverter driven machines. The main failure modes are presented, with analysis of available literature regarding machine failure. Gaps in literature are identified and the most common failure modes of the low voltage machine, bearing and winding damage are presented. Currently the area of least understanding in the field of drive health monitoring involves the measurement and analysis of winding insulation failure. The modes of insulation failure are investigated in detail and a new model for ground-wall insulation is developed. Methods to measure insulation ground-wall insulation have been reviewed, and a new method has been developed to monitor the ground-wall insulation health, during machine operation, using common-mode current inherent in inverter driven machines during operation. To expand the knowledge of insulation failure, the novel insulation health monitoring method is used to monitor four stators during an accelerated ageing test, representing monitoring of insulation of real machine lifetimes. The results are analysed and additional testing is presented in order to develop the monitoring system for standard industry drives. The major conclusion from results indicates that insulation degradation progression follows a deterministic trend, with clearly defined threshold of failure, allowing prognosis of lifetime based on monitored parameters. Future work recommendations are made to expand on the findings during the course of research

    Design and fabrication of a long-life Stirling cycle cooler for space application. Phase 3: Prototype model

    Get PDF
    A second-generation, Stirling-cycle cryocooler (cryogenic refrigerator) for space applications, with a cooling capacity of 5 watts at 65 K, was recently completed. The refrigerator, called the Prototype Model, was designed with a goal of 5 year life with no degradation in cooling performance. The free displacer and free piston of the refrigerator are driven directly by moving-magnet linear motors with the moving elements supported by active magnetic bearings. The use of clearance seals and the absence of outgassing material in the working volume of the refrigerator enable long-life operation with no deterioration in performance. Fiber-optic sensors detect the radial position of the shafts and provide a control signal for the magnetic bearings. The frequency, phase, stroke, and offset of the compressor and expander are controlled by signals from precision linear position sensors (LVDTs). The vibration generated by the compressor and expander is cancelled by an active counter balance which also uses a moving-magnet linear motor and magnetic bearings. The driving signal for the counter balance is derived from the compressor and expander position sensors which have wide bandwidth for suppression of harmonic vibrations. The efficiency of the three active members, which operate in a resonant mode, is enhanced by a magnetic spring in the expander and by gas springs in the compressor and counterbalance. The cooling was achieved with a total motor input power of 139 watts. The magnetic-bearing stiffness was significantly increased from the first-generation cooler to accommodate shuttle launch vibrations

    Embedded Sensors and Controls to Improve Component Performance and Reliability Conceptual Design Report

    Full text link
    • …