18,668 research outputs found

    Extended mixed integer quadratic programming for simultaneous distributed generation location and network reconfiguration

    Get PDF
    Introduction. To minimise power loss, maintain the voltage within the acceptable range, and improve power quality in power distribution networks, reconfiguration and optimal distributed generation placement are presented. Power flow analysis and advanced optimization techniques that can handle significant combinatorial problems must be used in distribution network reconfiguration investigations. The optimization approach to be used depends on the size of the distribution network. Our methodology simultaneously addresses two nonlinear discrete optimization problems to construct an intelligent algorithm to identify the best solution. The proposed work is novel in that it the Extended Mixed-Integer Quadratic Programming (EMIQP) technique, a deterministic approach for determining the topology that will effectively minimize power losses in the distribution system by strategically sizing and positioning Distributed Generation (DG) while taking network reconfiguration into account. Using an efficient Quadratic Mixed Integer Programming (QMIP) solver (IBM ®), the resulting optimization problem has a quadratic form. To ascertain the range and impact of various variables, our methodology outperforms cutting-edge algorithms described in the literature in terms of the obtained power loss reduction, according to extensive numerical validation carried out on typical IEEE 33-and 69-bus systems at three different load factors. Practical value. Examining the effectiveness of concurrent reconfiguration and DG allocation versus sole reconfiguration is done using test cases. According to the findings, network reconfiguration along with the installation of a distributed generator in the proper location, at the proper size, with the proper loss level, and with a higher profile, is effective. References 24, table 4, figures 14

    Optimized Solar Photovoltaic Generation in a Real Local Distribution Network

    Full text link
    Remarkable penetration of renewable energy in electric networks, despite its valuable opportunities, such as power loss reduction and loadability improvements, has raised concerns for system operators. Such huge penetration can lead to a violation of the grid requirements, such as voltage and current limits and reverse power flow. Optimal placement and sizing of Distributed Generation (DG) are one of the best ways to strengthen the efficiency of the power systems. This paper builds a simulation model for the local distribution network based on obtained load profiles, GIS information, solar insolation, feeder and voltage settings, and define the optimization problem of solar PVDG installation to determine the optimal siting and sizing for different penetration levels with different objective functions. The objective functions include voltage profile improvement and energy loss minimization and the considered constraints include the physical distribution network constraints (AC power flow), the PV capacity constraint, and the voltage and reverse power flow constraints.Comment: To be published (Accepted) in: Proceedings of the IEEE PES Innovative Smart Grid Technologies Conference (ISGT), Washington D.C., USA, 201

    Distribution System Planning with Distributed Generation: Optimal versus Heuristic Approach

    Get PDF
    Distribution system design and planning is facing a major change in paradigm because of deregulation of the power industry and with rapid penetration of distributed generation (DG) sources. Distribution system design and planning are key features for determining the best expansion strategies to provide reliable and economic services to the customer. In classical planning, the load growth is typically met by adding a new substation or upgrading the existing substation capacity along with their feeders. Today, rapid advances in DG technology and their numerous benefits have made them an attractive option to the distribution companies, power system planners and operators, energy policy makers and regulators, as well as developers. This thesis first presents a comprehensive planning framework for the distribution system from the distribution company perspective. It incorporates DG units as an option for local distribution companies (LDCs) and determines the sizing, placement and upgrade plans for feeders and substations. Thereafter, a new heuristic approach to multi-year distribution system planning is proposed which is based on a back-propagation algorithm starting from the terminal year and arriving at the first year. It is based on cost-benefit analysis, which incorporates various energy supply options for LDCs such as DG, substations and feeders and determines the size, placement and upgrade plan. The proposed heuristic approach combines a bi-level procedure in which Level-1 selects the optimal size and location of distribution system component upgrades and Level-2 determines the optimal period of commissioning for the selected upgrades in Level-1. The proposed heuristic is applied to a 32-bus radial distribution system. The first level of the distribution system planning framework is formulated as a mixed integer linear programming (MILP) problem while the second level is a linear programming (LP) model. The results demonstrate that the proposed approach can achieve better performance than a full optimization for the same distribution system

    Spring search algorithm for simultaneous placement of distributed generation and capacitors

    Get PDF
    Purpose. In this paper, for simultaneous placement of distributed generation (DG) and capacitors, a new approach based on Spring Search Algorithm (SSA), is presented. This method is contained two stages using two sensitive index Sv and Ss. Sv and Ss are calculated according to nominal voltageand network losses. In the first stage, candidate buses are determined for installation DG and capacitors according to Sv and Ss. Then in the second stage, placement and sizing of distributed generation and capacitors are specified using SSA. The spring search algorithm is among the optimization algorithms developed by the idea of laws of nature and the search factors are a set of objects. The proposed algorithm is tested on 33-bus and 69-bus radial distribution networks. The test results indicate good performance of the proposed methodЦель. В статье для одновременного размещения распределенной генерации и конденсаторов представлен новый подход, основанный на "пружинном" алгоритме поиска (Spring Search Algorithm, SSA). Данный метод состоит из двух этапов с использованием двух показателей чувствительности Sv и Ss. Показатели чувствительности Sv и Ss рассчитываются в соответствии с номинальным напряжением и потерями в сети. На первом этапе определяются шины-кандидаты для установки распределенной генерации и конденсаторов согласно Sv и Ss. Затем, на втором этапе размещение и калибровка распределенной генерации и конденсаторов выполняются с использованием алгоритма SSA. "Пружинный" алгоритм поиска входит в число алгоритмов оптимизации, разработанных на основе идей законов природы, а факторы поиска представляют собой набор объектов. Предлагаемый алгоритм тестируется на радиальных распределительных сетях с 33 и 69 шинами. Результаты тестирования показывают хорошую эффективность предложенного метода

    Optimal Number, Location, and Size of Distributed Generators in Distribution Systems by Symbiotic Organism Search Based Method

    Get PDF
    This paper proposes an approach based on the Symbiotic Organism Search (SOS) for optimal determining sizing, siting, and number of Distributed Generations (DG) in distribution systems. The objective of the problem is to minimize the power loss of the system subject to the equality and inequality constraints such as power balance, bus voltage limits, DG capacity limits, and DG penetration limit. The SOS approach is defined as the symbiotic relationship observed between two organisms in an ecosystem, which does not need the control parameters like other meta-heuristic algorithms in the literature. For the implementation of the proposed method to the problem, an integrated approach of Loss Sensitivity Factor (LSF) is used to determine the optimal location for installation of DG units, and SOS is used to find the optimal size of DG units. The proposed method has been tested on IEEE 33-bus, 69-bus, and 118-bus radial distribution systems. The obtained results from the SOS algorithm have been compared to those of other methods in the literature. The simulated results have demonstrated that the proposed SOS method has a very good performance and effectiveness for the problem of optimal placement of DG units in distribution systems

    Optimal Microgrid Topology Design and Siting of Distributed Generation Sources Using a Multi-Objective Substrate Layer Coral Reefs Optimization Algorithm

    Get PDF
    n this work, a problem of optimal placement of renewable generation and topology design for a Microgrid (MG) is tackled. The problem consists of determining the MG nodes where renewable energy generators must be optimally located and also the optimization of the MG topology design, i.e., deciding which nodes should be connected and deciding the lines’ optimal cross-sectional areas (CSA). For this purpose, a multi-objective optimization with two conflicting objectives has been used, utilizing the cost of the lines, C, higher as the lines’ CSA increases, and the MG energy losses, E, lower as the lines’ CSA increases. To characterize generators and loads connected to the nodes, on-site monitored annual energy generation and consumption profiles have been considered. Optimization has been carried out by using a novel multi-objective algorithm, the Multi-objective Substrate Layers Coral Reefs Optimization algorithm (Mo-SL-CRO). The performance of the proposed approach has been tested in a realistic simulation of a MG with 12 nodes, considering photovoltaic generators and micro-wind turbines as renewable energy generators, as well as the consumption loads from different commercial and industrial sites. We show that the proposed Mo-SL-CRO is able to solve the problem providing good solutions, better than other well-known multi-objective optimization techniques, such as NSGA-II or multi-objective Harmony Search algorithm.This research was partially funded by Ministerio de Economía, Industria y Competitividad, project number TIN2017-85887-C2-1-P and TIN2017-85887-C2-2-P, and by the Comunidad Autónoma de Madrid, project number S2013ICE-2933_02

    Smart Grid for the Smart City

    Get PDF
    Modern cities are embracing cutting-edge technologies to improve the services they offer to the citizens from traffic control to the reduction of greenhouse gases and energy provisioning. In this chapter, we look at the energy sector advocating how Information and Communication Technologies (ICT) and signal processing techniques can be integrated into next generation power grids for an increased effectiveness in terms of: electrical stability, distribution, improved communication security, energy production, and utilization. In particular, we deliberate about the use of these techniques within new demand response paradigms, where communities of prosumers (e.g., households, generating part of their electricity consumption) contribute to the satisfaction of the energy demand through load balancing and peak shaving. Our discussion also covers the use of big data analytics for demand response and serious games as a tool to promote energy-efficient behaviors from end users
    corecore