1,107 research outputs found
Medical image computing and computer-aided medical interventions applied to soft tissues. Work in progress in urology
Until recently, Computer-Aided Medical Interventions (CAMI) and Medical
Robotics have focused on rigid and non deformable anatomical structures.
Nowadays, special attention is paid to soft tissues, raising complex issues due
to their mobility and deformation. Mini-invasive digestive surgery was probably
one of the first fields where soft tissues were handled through the development
of simulators, tracking of anatomical structures and specific assistance
robots. However, other clinical domains, for instance urology, are concerned.
Indeed, laparoscopic surgery, new tumour destruction techniques (e.g. HIFU,
radiofrequency, or cryoablation), increasingly early detection of cancer, and
use of interventional and diagnostic imaging modalities, recently opened new
challenges to the urologist and scientists involved in CAMI. This resulted in
the last five years in a very significant increase of research and developments
of computer-aided urology systems. In this paper, we propose a description of
the main problems related to computer-aided diagnostic and therapy of soft
tissues and give a survey of the different types of assistance offered to the
urologist: robotization, image fusion, surgical navigation. Both research
projects and operational industrial systems are discussed
Robot Autonomy for Surgery
Autonomous surgery involves having surgical tasks performed by a robot
operating under its own will, with partial or no human involvement. There are
several important advantages of automation in surgery, which include increasing
precision of care due to sub-millimeter robot control, real-time utilization of
biosignals for interventional care, improvements to surgical efficiency and
execution, and computer-aided guidance under various medical imaging and
sensing modalities. While these methods may displace some tasks of surgical
teams and individual surgeons, they also present new capabilities in
interventions that are too difficult or go beyond the skills of a human. In
this chapter, we provide an overview of robot autonomy in commercial use and in
research, and present some of the challenges faced in developing autonomous
surgical robots
New Mechatronic Systems for the Diagnosis and Treatment of Cancer
Both two dimensional (2D) and three dimensional (3D) imaging modalities are useful tools for viewing the internal anatomy. Three dimensional imaging techniques are required for accurate targeting of needles. This improves the efficiency and control over the intervention as the high temporal resolution of medical images can be used to validate the location of needle and target in real time. Relying on imaging alone, however, means the intervention is still operator dependent because of the difficulty of controlling the location of the needle within the image. The objective of this thesis is to improve the accuracy and repeatability of needle-based interventions over conventional techniques: both manual and automated techniques. This includes increasing the accuracy and repeatability of these procedures in order to minimize the invasiveness of the procedure.
In this thesis, I propose that by combining the remote center of motion concept using spherical linkage components into a passive or semi-automated device, the physician will have a useful tracking and guidance system at their disposal in a package, which is less threatening than a robot to both the patient and physician. This design concept offers both the manipulative transparency of a freehand system, and tremor reduction through scaling currently offered in automated systems. In addressing each objective of this thesis, a number of novel mechanical designs incorporating an remote center of motion architecture with varying degrees of freedom have been presented. Each of these designs can be deployed in a variety of imaging modalities and clinical applications, ranging from preclinical to human interventions, with an accuracy of control in the millimeter to sub-millimeter range
On uncertainty propagation in image-guided renal navigation: Exploring uncertainty reduction techniques through simulation and in vitro phantom evaluation
Image-guided interventions (IGIs) entail the use of imaging to augment or replace direct vision during therapeutic interventions, with the overall goal is to provide effective treatment in a less invasive manner, as an alternative to traditional open surgery, while reducing patient trauma and shortening the recovery time post-procedure. IGIs rely on pre-operative images, surgical tracking and localization systems, and intra-operative images to provide correct views of the surgical scene. Pre-operative images are used to generate patient-specific anatomical models that are then registered to the patient using the surgical tracking system, and often complemented with real-time, intra-operative images. IGI systems are subject to uncertainty from several sources, including surgical instrument tracking / localization uncertainty, model-to-patient registration uncertainty, user-induced navigation uncertainty, as well as the uncertainty associated with the calibration of various surgical instruments and intra-operative imaging devices (i.e., laparoscopic camera) instrumented with surgical tracking sensors. All these uncertainties impact the overall targeting accuracy, which represents the error associated with the navigation of a surgical instrument to a specific target to be treated under image guidance provided by the IGI system. Therefore, understanding the overall uncertainty of an IGI system is paramount to the overall outcome of the intervention, as procedure success entails achieving certain accuracy tolerances specific to individual procedures. This work has focused on studying the navigation uncertainty, along with techniques to reduce uncertainty, for an IGI platform dedicated to image-guided renal interventions. We constructed life-size replica patient-specific kidney models from pre-operative images using 3D printing and tissue emulating materials and conducted experiments to characterize the uncertainty of both optical and electromagnetic surgical tracking systems, the uncertainty associated with the virtual model-to-physical phantom registration, as well as the uncertainty associated with live augmented reality (AR) views of the surgical scene achieved by enhancing the pre-procedural model and tracked surgical instrument views with live video views acquires using a camera tracked in real time. To better understand the effects of the tracked instrument calibration, registration fiducial configuration, and tracked camera calibration on the overall navigation uncertainty, we conducted Monte Carlo simulations that enabled us to identify optimal configurations that were subsequently validated experimentally using patient-specific phantoms in the laboratory. To mitigate the inherent accuracy limitations associated with the pre-procedural model-to-patient registration and their effect on the overall navigation, we also demonstrated the use of tracked video imaging to update the registration, enabling us to restore targeting accuracy to within its acceptable range. Lastly, we conducted several validation experiments using patient-specific kidney emulating phantoms using post-procedure CT imaging as reference ground truth to assess the accuracy of AR-guided navigation in the context of in vitro renal interventions. This work helped find answers to key questions about uncertainty propagation in image-guided renal interventions and led to the development of key techniques and tools to help reduce optimize the overall navigation / targeting uncertainty
Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery
One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions
Computer- and robot-assisted Medical Intervention
Medical robotics includes assistive devices used by the physician in order to
make his/her diagnostic or therapeutic practices easier and more efficient.
This chapter focuses on such systems. It introduces the general field of
Computer-Assisted Medical Interventions, its aims, its different components and
describes the place of robots in that context. The evolutions in terms of
general design and control paradigms in the development of medical robots are
presented and issues specific to that application domain are discussed. A view
of existing systems, on-going developments and future trends is given. A
case-study is detailed. Other types of robotic help in the medical environment
(such as for assisting a handicapped person, for rehabilitation of a patient or
for replacement of some damaged/suppressed limbs or organs) are out of the
scope of this chapter.Comment: Handbook of Automation, Shimon Nof (Ed.) (2009) 000-00
Needle and Biopsy Robots: a Review
Purpose of the review Robotics is a rapidly advancing field, and its introduction in healthcare can have a multitude of benefits for clinical practice. Especially, applications depending on the radiologist\u2019s accuracy and precision, such as percutaneous interventions, may profit. This paper provides an overview of recent robot-assisted percutaneous solutions. Recent findings Percutaneous interventions are relatively simple and the quality of the procedure increases a lot by introducing robotics due to the improved accuracy and precision. The success of the procedure is heavily dependent on the ability to merge pre- and intraoperative images, as an accurate estimation of the current target location allows to exploit the robot\u2019s capabilities. Summary Despite much research, the application of robotics in some branches of healthcare is not commonplace yet. Recent advances in percutaneous robotic solutions and imaging are highlighted, as they will pave the way to more widespread implementation of robotics in clinical practic
- …