59,651 research outputs found

    A Practical Method for High-Resolution Embedded Liquid Surfaces

    Get PDF
    This is the peer reviewed version of the following article: Goldade, R., Batty, C., & Wojtan, C. (2016). A Practical Method for High-Resolution Embedded Liquid Surfaces. Computer Graphics Forum, 35(2), 233–242, which has been published in final form at https://doi.org/10.1111/cgf.12826. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.Combining high-resolution level set surface tracking with lower resolution physics is an inexpensive method for achieving highly detailed liquid animations. Unfortunately, the inherent resolution mismatch introduces several types of disturbing visual artifacts. We identify the primary sources of these artifacts and present simple, efficient, and practical solutions to address them. First, we propose an unconditionally stable filtering method that selectively removes sub-grid surface artifacts not seen by the fluid physics, while preserving fine detail in dynamic splashing regions. It provides comparable results to recent error-correction techniques at lower cost, without substepping, and with better scaling behavior. Second, we show how a modified narrow-band scheme can ensure accurate free surface boundary conditions in the presence of large resolution mismatches. Our scheme preserves the efficiency of the narrow-band methodology, while eliminating objectionable stairstep artifacts observed in prior work. Third, we demonstrate that the use of linear interpolation of velocity during advection of the high-resolution level set surface is responsible for visible grid-aligned kinks; we therefore advocate higher-order velocity interpolation, and show that it dramatically reduces this artifact. While these three contributions are orthogonal, our results demonstrate that taken together they efficiently address the dominant sources of visual artifacts arising with high-resolution embedded liquid surfaces; the proposed approach offers improved visual quality, a straightforward implementation, and substantially greater scalability than competing methods.This research was supported by NSERC (RGPIN-04360-2014), ERC (638176), and IST Austri

    Embedded Implicit Stand-ins for Animated Meshes: a Case of Hybrid Modelling

    Get PDF
    In this paper we address shape modelling problems, encountered in computer animation and computer games development that are difficult to solve just using polygonal meshes. Our approach is based on a hybrid modelling concept that combines polygonal meshes with implicit surfaces. A hybrid model consists of an animated polygonal mesh and an approximation of this mesh by a convolution surface stand-in that is embedded within it or is attached to it. The motions of both objects are synchronised using a rigging skeleton. This approach is used to model the interaction between an animated mesh object and a viscoelastic substance, normally modelled in implicit form. The adhesive behaviour of the viscous object is modelled using geometric blending operations on the corresponding implicit surfaces. Another application of this approach is the creation of metamorphosing implicit surface parts that are attached to an animated mesh. A prototype implementation of the proposed approach and several examples of modelling and animation with near real-time preview times are presented

    Fiber-taper coupling to Whispering-Gallery modes of fluidic resonators embedded in a liquid medium

    Get PDF
    We demonstrate efficient coupling to the optical Whispering-Gallery (WG) modes of a fluidic resonator consisting of a droplet embedded in a liquid medium. Unlike previous experiments the droplet is not levitated in an optical or electrostatic trap and free space coupling is replaced by phase-matched, waveguide coupling using a fiber-taper. We have observed critical coupling to fundamental WG modes of a 600 ÎŒm diameter water droplet at 980 nm. The experimental challenges towards making, stabilizing and coupling to the droplet resonators are addressed in this paper

    Path-tracing Monte Carlo Library for 3D Radiative Transfer in Highly Resolved Cloudy Atmospheres

    Full text link
    Interactions between clouds and radiation are at the root of many difficulties in numerically predicting future weather and climate and in retrieving the state of the atmosphere from remote sensing observations. The large range of issues related to these interactions, and in particular to three-dimensional interactions, motivated the development of accurate radiative tools able to compute all types of radiative metrics, from monochromatic, local and directional observables, to integrated energetic quantities. In the continuity of this community effort, we propose here an open-source library for general use in Monte Carlo algorithms. This library is devoted to the acceleration of path-tracing in complex data, typically high-resolution large-domain grounds and clouds. The main algorithmic advances embedded in the library are those related to the construction and traversal of hierarchical grids accelerating the tracing of paths through heterogeneous fields in null-collision (maximum cross-section) algorithms. We show that with these hierarchical grids, the computing time is only weakly sensitivive to the refinement of the volumetric data. The library is tested with a rendering algorithm that produces synthetic images of cloud radiances. Two other examples are given as illustrations, that are respectively used to analyse the transmission of solar radiation under a cloud together with its sensitivity to an optical parameter, and to assess a parametrization of 3D radiative effects of clouds.Comment: Submitted to JAMES, revised and submitted again (this is v2

    Implantable micromechanical parylene-based pressure sensors for unpowered intraocular pressure sensing

    Get PDF
    This paper presents the first implantable, unpowered, parylene-based microelectromechanical system (MEMS) pressure sensor for intraocular pressure (IOP) sensing. From in situ mechanical deformation of the compliant spiral-tube structures, this sensor registers pressure variations without electrical or powered signal transduction of any kind. Micromachined high-aspect-ratio polymeric hollow tubes with different geometric layouts are implemented to obtain high-sensitivity pressure responses. An integrated device packaging method has been developed toward enabling minimally invasive suture-less needle-based implantation of the device. Both in vitro and ex vivo device characterizations have successfully demonstrated mmHg resolution of the pressure responses. In vivo animal experiments have also been conducted to verify the biocompatibility and functionality of the implant fixation method inside the eye. Using the proposed implantation scheme, the pressure response of the implant can be directly observed from outside the eye under visible light, with the goal of realizing convenient, direct and faithful IOP monitoring in glaucoma patients

    Operating limits for acoustic measurement of rolling bearing oil film thickness

    Get PDF
    An ultrasonic pulse striking a thin layer of liquid trapped between solid bodies will be partially reflected. The proportion reflected is a function of the layer stiffness, which in turn depends on the film thickness and its bulk modulus. In this work, measurements of reflection have been used to determine the thickness of oil films in elastohydrodynamic lubricated (EHL) contacts. A very thin liquid layer behaves like a spring when struck by an ultrasonic pulse. A simple quasi-static spring model can be used to determine the proportion of the ultrasonic waves reflected. Experiments have been performed on a model EHL contact between a ball and a flat surface. A transducer is mounted above the contact such that the ultrasonic wave is focused onto the oil film. The reflected signals are captured and passed to a PC for processing. Fourier analysis gives the reflection spectrum that is then used to determine the stiffness of the liquid layer and hence its thickness. In further testing, an ultrasonic transducer has been mounted in the housing of a deep-groove ball bearing to measure the film generated at the outer raceway as each ball passes. Results from both the ball-flat and ball bearing measurements agree well with steady-state theoretical EHL predictions. The limits of the measuring technique, in terms of the measurable rolling bearing size and operating parameters, have been investigated

    A practical review on the measurement tools for cellular adhesion force

    Full text link
    Cell cell and cell matrix adhesions are fundamental in all multicellular organisms. They play a key role in cellular growth, differentiation, pattern formation and migration. Cell-cell adhesion is substantial in the immune response, pathogen host interactions, and tumor development. The success of tissue engineering and stem cell implantations strongly depends on the fine control of live cell adhesion on the surface of natural or biomimetic scaffolds. Therefore, the quantitative and precise measurement of the adhesion strength of living cells is critical, not only in basic research but in modern technologies, too. Several techniques have been developed or are under development to quantify cell adhesion. All of them have their pros and cons, which has to be carefully considered before the experiments and interpretation of the recorded data. Current review provides a guide to choose the appropriate technique to answer a specific biological question or to complete a biomedical test by measuring cell adhesion
    • 

    corecore