645 research outputs found

    Optical excitation and external photoluminescence quantum efficiency of Eu3+ in GaN

    Get PDF
    We investigate photoluminescence of Eu-related emission in a GaN host consisting of thin layers grown by organometallic vapor-phase epitaxy. By comparing it with a reference sample of Eu-doped Y2O3, we find that the fraction of Eu3+ ions that can emit light upon optical excitation is of the order of 1%. We also measure the quantum yield of the Eu-related photoluminescence and find this to reach (similar to 10%) and (similar to 3%) under continuous wave and pulsed excitation, respectively.Stichting voor de Technologische Wetenschappen (STW); Japan Society for the Promotion of Science [19GS1209, 24226009]; Ministry of Education, Culture, Sports, Science and Technology of Japaninfo:eu-repo/semantics/publishedVersio

    How suitable is freshwater sponge Ephydatia fluviatilis (Linnaeus, 1759) for time-integrated biomonitoring of microbial water quality?

    Get PDF
    Faecal pollution of water by bacteria has a negative effect on water quality and can pose a potential health hazard. Conventional surveillance of microbial water quality relies on the analysis of low frequency spot samples and is thus likely to miss episodic or periodic pollution. This study aimed to investigate the potential of filter feeding sponges for time-integrated biomonitoring of microbial water quality. Laboratory trials tested the effects of different ratios of bacterial abundance and the sequence of exposure on bacterial retention by the freshwater sponge Ephydatia fluviatilis (Linnaeus, 1759) to establish its potential to indicate bacterial exposure. Gemmule grown sponges were simultaneously exposed to Escherichia coli and Enterococcus faecalis but at different ratios (Trial 1) or individually exposed to each bacterial species but in different sequential order (Trial 2). The E. coli and E. faecalis retained in each sponge was quantified by culture on selective agars. Data analysis was conducted using the Kruskal- Wallis test and/ or the Mann Whitney U test to compare between the numbers of bacteria retained in each treatment. Additionally, the Wilcoxon Matched-Paired Signed-Rank test was used for comparison of the different bacterial abundances retained within each individual sponge. Sponges from all trials retained E. coli and E. faecalis in small numbers relative to the exposure (<0.05% Trial 1 and <0.07% Trial 2) but exhibited higher retention of E. coli. Higher abundance of either bacterial species resulted in significantly lower (p<0.005) retention of the same species within sponges (Trial 1). An initial exposure to E. coli resulted in significantly higher (p=0.040) retention of both bacterial species than when sponges were exposed to E. faecalis first (Trial 2). Bacterial retention by sponges was neither quantitatively representative of bacterial abundance in the ambient water nor the sequence of exposure. This implies either selective filtration or an attempt by sponges to prevent infection. However, freshwater sponges may still be useful in biomonitoring as qualitative time-integrated samplers of faecal indicator bacteria as they detect different bacteria present in the water even if their quantities cannot be estimated

    Low-cost 3D printed 1  nm resolution smartphone sensor-based spectrometer: instrument design and application in ultraviolet spectroscopy.

    Get PDF
    We report on the development of a low-cost spectrometer, based on off-the-shelf optical components, a 3D printed housing, and a modified Raspberry Pi camera module. With a bandwidth and spectral resolution of ≈60  nm and 1 nm, respectively, this device was designed for ultraviolet (UV) remote sensing of atmospheric sulphur dioxide (SO2), ≈310  nm. To the best of our knowledge, this is the first report of both a UV spectrometer and a nanometer resolution spectrometer based on smartphone sensor technology. The device performance was assessed and validated by measuring column amounts of SO2 within quartz cells with a differential optical absorption spectroscopy processing routine. This system could easily be reconfigured to cover other UV-visible-near-infrared spectral regions, as well as alternate spectral ranges and/or linewidths. Hence, our intention is also to highlight how this framework could be applied to build bespoke, low-cost, spectrometers for a range of scientific applications

    High time resolution fluctuations in volcanic carbon dioxide degassing from Mount Etna

    Get PDF
    We report here on the first record of carbon dioxide gas emission rates from a volcano, captured at ≈ 1 Hz. These data were acquired with a novel technique, based on the integration of UV camera observations (to measure SO2 emission rates) and field portable gas analyser readings of plume CO2/SO2 ratios. Our measurements were performedat the North East crater of Mount Etna, southern Italy, and the data reveal strong variability in CO2 emissions over timescales of tens to hundreds of seconds, spanning two orders of magnitude. This carries importantimplications for attempts to constrain global volcanic CO2 release to the atmosphere, and will lead to an increased insight into short term CO2 degassing trends. A common oscillation in CO2 and SO2 emission rates in addition to the CO2/SO2 ratios was observed at periods of ≈ 89 s. Our results are furthermore suggestive of an intriguing temporal lag between oscillations in CO2 emissions and seismicity at periods of ≈ 300–400 s, with peaks and troughs in the former series leading those in the latter by ≈ 150 s. This work opens the way to the acquisition of further datasets with this methodology across a range of basaltic systems to better our understandingof deep magmatic processes and of degassing links to manifest geophysical signals

    Dynamics of soap bubble bursting and its implications to volcano acoustics

    Get PDF
    In order to assess the physical mechanisms at stake when giant gas bubbles burst at the top of a magma conduit, laboratory experiments have been performed. An overpressurized gas cavity is initially closed by a thin liquid film, which suddenly bursts. The acoustic signal produced by the bursting is investigated. The key result is that the amplitude and energy of the acoustic signal strongly depend on the film rupture time. As the rupture time is uncontrolled in the experiments and in the field, the measurement of the acoustic excess pressure in the atmosphere, alone, cannot provide any information on the overpressure inside the bubble before explosion. This could explain the low energy partitioning between infrasound, seismic and explosive dynamics often observed on volcanoes

    Low-cost hyperspectral imaging system: Design and testing for laboratory-based environmental applications

    Get PDF
    The recent surge in the development of low-cost, miniaturised technologies provides a significant opportunity to develop miniaturised hyperspectral imagers at a fraction of the cost of currently available commercial set-ups. This article introduces a low-cost laboratory-based hyperspectral imager developed using commercially available components. The imager is capable of quantitative and qualitative hyperspectral measurements, and it was tested in a variety of laboratory-based environmental applications where it demonstrated its ability to collect data that correlates well with existing datasets. In its current format, the imager is an accurate laboratory measurement tool, with significant potential for ongoing future developments. It represents an initial development in accessible hyperspectral technologies, providing a robust basis for future improvements

    Ultraviolet imaging of volcanic plumes: A new paradigm in volcanology

    Get PDF
    Ultraviolet imaging has been applied in volcanology over the last ten years or so. This provides considerably higher temporal and spatial resolution volcanic gas emission rate data than available previously, enabling the volcanology community to investigate a range of far faster plume degassing processes than achievable hitherto. To date, this has covered rapid oscillations in passive degassing through conduits and lava lakes, as well as puffing and explosions, facilitating exciting connections to be made for the first time between previously rather separate sub-disciplines of volcanology. Firstly, there has been corroboration between geophysical and degassing datasets at ≈1 Hz, expediting more holistic investigations of volcanic source-process behaviour. Secondly, there has been the combination of surface observations of gas release with fluid dynamic models (numerical, mathematical, and laboratory) for gas flow in conduits, in attempts to link subterranean driving flow processes to surface activity types. There has also been considerable research and development concerning the technique itself, covering error analysis and most recently the adaptation of smartphone sensors for this application, to deliver gas fluxes at a significantly lower instrumental price point than possible previously. At this decadal juncture in the application of UV imaging in volcanology, this article provides an overview of what has been achieved to date as well as a forward look to possible future research directions

    Plant-Mycorrhiza Percent Infection as Evidence of Coupled Metabolism

    Full text link
    A common feature of mycorrhizal observation is the growth of the infection on the plant root as a percent of the infected root or root tip length. Often, this is measured as a logistic curve with an eventual, though usually transient, plateau. It is shown in this paper that the periods of stable percent infection in the mycorrhizal growth cycle correspond to periods where both the plant and mycorrhiza growth rates and likely metabolism are tightly coupled.Comment: 11 pages; accepted by the Journal of Theoretical Biology (in press

    Conduit dynamics and post-explosion degassing on Stromboli:a combined UV camera and 1 numerical modelling treatment

    Get PDF
    Recent gas flux measurements have shown that strombolian explosions are often followed by periods of elevated flux, or ‘gas codas’, with durations of order a minute. Here, we present UV camera data from 200 events recorded at Stromboli volcano to constrain the nature of these codas for the first time, providing estimates for combined explosion plus coda SO2 masses of ≈ 18 – 225 kg. Numerical simulations of gas slug ascent show that substantial proportions of the initial gas mass can be distributed into a train of ‘daughter bubbles’ released from the base of the slug, which we suggest, generate the codas, on bursting at the surface. This process could also cause transitioning of slugs into cap bubbles, significantly reducing explosivity. This study is the first attempt to combine high temporal resolution gas flux data with numerical simulations of conduit gas flow to investigate volcanic degassing dynamics
    • 

    corecore