98 research outputs found

    Bioactive Inks Development for Osteochondral Tissue Engineering: A Mini-Review

    Get PDF
    Nowadays, a prevalent joint disease affecting both cartilage and subchondral bone is osteoarthritis. Osteochondral tissue, a complex tissue unit, exhibited limited self-renewal potential. Furthermore, its gradient properties, including mechanical property, bio-compositions, and cellular behaviors, present a challenge in repairing and regenerating damaged osteochondral tissues. Here, tissue engineering and translational medicine development using bioprinting technology provided a promising strategy for osteochondral tissue repair. In this regard, personalized stratified scaffolds, which play an influential role in osteochondral regeneration, can provide potential treatment options in early-stage osteoarthritis to delay or avoid the use of joint replacements. Accordingly, bioactive scaffolds with possible integration with surrounding tissue and controlling inflammatory responses have promising future tissue engineering perspectives. This minireview focuses on introducing biologically active inks for bioprinting the hierarchical scaffolds, containing growth factors and bioactive materials for 3D printing of regenerative osteochondral substitutes

    A critical review on polydopamine surface-modified scaffolds in musculoskeletal regeneration

    Get PDF
    Increasing concern about age-related diseases, particularly musculoskeletal injuries and orthopedic conditions, highlights the need for strategies such as tissue engineering to address them. Surface modification has been developed to create pro-healing interfaces, personalize scaffolds and provide novel medicines. Polydopamine, a mussel-inspired adhesive polymer with highly reactive functional groups that adhere to nearly all substrates, has gained attention in surface modification strategies for biomaterials. Polydopamine was primarily developed to modify surfaces, but its effectiveness has opened up promising approaches for further applications in bioengineering as carriers and nanoparticles. This review focuses on the recent discoveries of the role of polydopamine as a surface coating material, with focus on the properties that make it suitable for tackling musculoskeletal disorders. We report the evolution of using it in research, and discuss papers involving the progress of this field. The current research on the role of polydopamine in bone, cartilage, muscle, nerve, and tendon regeneration is discussed, thus giving comprehensive overview about the function of polydopamine both in-vitro and in-vivo. Finally, the report concludes presenting the critical challenges that must be addressed for the clinical translation of this biomaterial while exploring future perspectives and research opportunities in this area

    Modelling and simulation of a single slit micro packed bed reactor for methanol synthesis

    Get PDF
    A mathematical model for a single slit packed microstructured reactor-heat exchanger in the synthesis of methanol from syngas was developed. The model constitutes a simplified 3D-pseudo homogeneous approach for a reaction slit with integrated pillar geometry. Literature kinetic rate expressions for methanol synthesis over commercial Cu/ZnO/support type catalysts were applied at 80 bar total pressure, temperature range of 473-558 K, and syngas composition of H2_{2}/CO/CO2_{2}/N2_{2}:65/25/ 5/5 mol%. The model is found capable of predicting experimental CO conversion data with acceptable accuracy. Superior thermal stability of the microchannel upon variation of different parameters such as contact time, feed gas temperature and reaction temperature were shown. The simulation results also reveal that the microchannel reactor can operate free of performance loss due to concentrations field that may arise from overlaid temperature fields. Simulations have also been used to calculate the rapid temperature transients at the inlet. The agreement between simulation results and experimental data signifies the applicability of the developed model for further design and performance optimization of microstructured reactors for methanol synthesis and other exothermic processes

    Fluid-structure interaction simulation of prosthetic aortic valves : comparison between immersed boundary and arbitrary Lagrangian-Eulerian techniques for the mesh representation

    Get PDF
    In recent years the role of FSI (fluid-structure interaction) simulations in the analysis of the fluid-mechanics of heart valves is becoming more and more important, being able to capture the interaction between the blood and both the surrounding biological tissues and the valve itself. When setting up an FSI simulation, several choices have to be made to select the most suitable approach for the case of interest: in particular, to simulate flexible leaflet cardiac valves, the type of discretization of the fluid domain is crucial, which can be described with an ALE (Arbitrary Lagrangian-Eulerian) or an Eulerian formulation. The majority of the reported 3D heart valve FSI simulations are performed with the Eulerian formulation, allowing for large deformations of the domains without compromising the quality of the fluid grid. Nevertheless, it is known that the ALE-FSI approach guarantees more accurate results at the interface between the solid and the fluid. The goal of this paper is to describe the same aortic valve model in the two cases, comparing the performances of an ALE-based FSI solution and an Eulerian-based FSI approach. After a first simplified 2D case, the aortic geometry was considered in a full 3D set-up. The model was kept as similar as possible in the two settings, to better compare the simulations' outcomes. Although for the 2D case the differences were unsubstantial, in our experience the performance of a full 3D ALE-FSI simulation was significantly limited by the technical problems and requirements inherent to the ALE formulation, mainly related to the mesh motion and deformation of the fluid domain. As a secondary outcome of this work, it is important to point out that the choice of the solver also influenced the reliability of the final results

    Interlaminar Fracture Toughness Evaluation in Glass/Epoxy Composites Using Acoustic Emission and Finite Element Methods

    Get PDF
    © 2014, ASM International. Delamination is one of the most common modes of failure in laminated composites and it leads to the loss of structural strength and stiffness. In this paper, mode I, mode II, and mixed of these pure modes were investigated using mechanical data, Finite Element Method (FEM) and Acoustic Emission (AE) signals. Experimental data were obtained from insitu monitoring of glass/epoxy laminated composites with different lay-ups when subjected to different modes of failure. The main objective was to investigate the behavior of delamination propagation and to evaluate the critical value of the strain energy which is required for onset of the delamination (GC). For the identification of interlaminar fracture toughness of the specimens, four methods were used: (a) ASTM standard methods, (b) FEM analysis, (c) AE method, and (d) sentry function method which is a function of mechanical and AE behaviors of the specimens. The results showed that the GC values obtained by the sentry function method and FEM analysis were in a close agreement with the results of nonlinearity methods which is recommended in the ASTM standards. It was also found that the specimens under different loading conditions and various lay-up have different GC values. These differences are related to different stress components distribution in the specimens which induce various damage mechanisms. Accordingly, stress components distribution obtained from FEM analyses were in agreement with SEM observations of the damaged surfaces of the specimens

    The Northern Route for Human dispersal in Central and Northeast Asia: New evidence from the site of Tolbor-16, Mongolia.

    Get PDF
    The fossil record suggests that at least two major human dispersals occurred across the Eurasian steppe during the Late Pleistocene. Neanderthals and Modern Humans moved eastward into Central Asia, a region intermittently occupied by the enigmatic Denisovans. Genetic data indicates that the Denisovans interbred with Neanderthals near the Altai Mountains (South Siberia) but where and when they met H. sapiens is yet to be determined. Here we present archaeological evidence that document the timing and environmental context of a third long-distance population movement in Central Asia, during a temperate climatic event around 45,000 years ago. The early occurrence of the Initial Upper Palaeolithic, a techno-complex whose sudden appearance coincides with the first occurrence of H. sapiens in the Eurasian steppes, establishes an essential archaeological link between the Siberian Altai and Northwestern China . Such connection between regions provides empirical ground to discuss contacts between local and exogenous populations in Central and Northeast Asia during the Late Pleistocene

    Extra-corporeal membrane oxygenation for refractory cardiogenic shock after adult cardiac surgery:a systematic review and meta-analysis

    Get PDF
    Background - Postcardiotomy cardiogenic shock (PCCS) refractory to inotropic support and intra-aortic balloon pump (IABP) occurs rarely but is almost universally fatal without mechanical circulatory support. In this systematic review and meta-analysis we looked at the evidence behind the use of veno-arterial extra-corporeal membrane oxygenation (VA ECMO) in refractory PCCS from a patient survival rate and determinants of outcome viewpoint. Methods - A systematic review was performed in January 2017 using PubMed (with no defined time period) using the keywords “postcardiotomy”, “cardiogenic shock”, “extracorporeal membrane oxygenation” and “cardiac surgery”. We excluded papers pertaining to ECMO following paediatric cardiac surgery, medical causes of cardiogenic shock, as well as case reports, review articles, expert opinions, and letters to the editor. Once the studies were collated, a meta-analysis was performed on the proportion of survivors in those papers that met the inclusion criteria. Meta-regression was performed for the most commonly reported adverse prognostic indicators (API). Results - We identified 24 studies and a cumulative pool of 1926 patients from 1992 to 2016. We tabulated the demographic data, including the strengths and weaknesses for each of the studies, outcomes of VA ECMO for refractory PCCS, complications, and APIs. All the studies were retrospective cohort studies. Meta-analysis of the moderately heterogeneous data (95% CI 0.29 to 0.34, p 70 years, 95% CI −0.057 to 0.001, P = 0.058), and long ECMO support (95% CI −0.068 to 0.166, P = 0.412). Postoperative renal failure, high EuroSCORE (>20%), diabetes mellitus, obesity, rising lactate whilst on ECMO, gastrointestinal complications had also been reported. Conclusion - Haemodynamic support with VA ECMO provides a survival benefit with reasonable intermediate and long-term outcomes. Many studies had reported advanced age, renal failure and prolonged VA ECMO support as the most likely APIs for VA ECMO in PCCS. EuroSCORE can be utilized to anticipate the need for prophylactic perioperative VA ECMO in the high-risk category. APIs can be used to aid decision-making regarding both the institution and weaning of ECMO for refractory PCCS
    corecore