79 research outputs found

    Supporting carers to manage pain medication in cancer patients at the end of life: A feasibility trial

    Get PDF
    Background: Carers of people with advanced cancer play a significant role in managing pain medication, yet they report insufficient information and support to do so confidently and competently. There is limited research evidence on the best ways for clinicians to help carers with medication management. Aims: To develop a pain medicines management intervention (Cancer Carers Medicines Management) for cancer patients’ carers near the end of life and evaluate feasibility and acceptability to nurses and carers. To test the feasibility of trial research procedures and to inform decisions concerning a full-scale randomised controlled trial. Design: Phase I-II clinical trial. A systematic, evidence-informed participatory method was used to develop CCMM: a nurse-delivered structured conversational process. A two-arm, cluster randomised controlled feasibility trial of Cancer Carers Medicines Management was conducted, with an embedded qualitative study to evaluate participants’ experiences of Cancer Carers Medicines Management and trial procedures. Setting: Community settings in two study sites. Participants: Phase I comprises 57 carers, patients and healthcare professionals and Phase II comprises 12 nurses and 15 carers. Results: A novel intervention was developed. Nurses were recruited and randomised. Carer recruitment to the trial was problematic with fewer than predicted eligible participants, and nurses judged a high proportion unsuitable to recruit into the study. Attrition rates following recruitment were typical for the study population. Cancer Carers Medicines Management was acceptable to carers and nurses who took part, and some benefits were identified. Conclusion: Cancer Carers Medicines Management is a robustly developed medicines management intervention which merits further research to test its effectiveness to improve carers’ management of pain medicines with patients at the end of life. The study highlighted aspects of trial design that need to be considered in future research

    Automated imaging technologies for the diagnosis of glaucoma: a comparative diagnostic study for the evaluation of the diagnostic accuracy, performance as triage tests and cost-effectiveness (GATE study)

    Get PDF
    BACKGROUND: Many glaucoma referrals from the community to hospital eye services are unnecessary. Imaging technologies can potentially be useful to triage this population. OBJECTIVES: To assess the diagnostic performance and cost-effectiveness of imaging technologies as triage tests for identifying people with glaucoma. DESIGN: Within-patient comparative diagnostic accuracy study. Markov economic model comparing the cost-effectiveness of a triage test with usual care. SETTING: Secondary care. PARTICIPANTS: Adults referred from the community to hospital eye services for possible glaucoma. INTERVENTIONS: Heidelberg Retinal Tomography (HRT), including two diagnostic algorithms, glaucoma probability score (HRT-GPS) and Moorfields regression analysis (HRT-MRA); scanning laser polarimetry [glaucoma diagnostics (GDx)]; and optical coherence tomography (OCT). The reference standard was clinical examination by a consultant ophthalmologist with glaucoma expertise including visual field testing and intraocular pressure (IOP) measurement. MAIN OUTCOME MEASURES: (1) Diagnostic performance of imaging, using data from the eye with most severe disease. (2) Composite triage test performance (imaging test, IOP measurement and visual acuity measurement), using data from both eyes, in correctly identifying clinical management decisions, that is 'discharge' or 'do not discharge'. Outcome measures were sensitivity, specificity and incremental cost per quality-adjusted life-year (QALY). RESULTS: Data from 943 of 955 participants were included in the analysis. The average age was 60.5 years (standard deviation 13.8 years) and 51.1% were females. Glaucoma was diagnosed by the clinician in at least one eye in 16.8% of participants; 37.9% of participants were discharged after the first visit. Regarding diagnosing glaucoma, HRT-MRA had the highest sensitivity [87.0%, 95% confidence interval (CI) 80.2% to 92.1%] but the lowest specificity (63.9%, 95% CI 60.2% to 67.4%) and GDx had the lowest sensitivity (35.1%, 95% CI 27.0% to 43.8%) but the highest specificity (97.2%, 95% CI 95.6% to 98.3%). HRT-GPS had sensitivity of 81.5% (95% CI 73.9% to 87.6%) and specificity of 67.7% (95% CI 64.2% to 71.2%) and OCT had sensitivity of 76.9% (95% CI 69.2% to 83.4%) and specificity of 78.5% (95% CI 75.4% to 81.4%). Regarding triage accuracy, triage using HRT-GPS had the highest sensitivity (86.0%, 95% CI 82.8% to 88.7%) but the lowest specificity (39.1%, 95% CI 34.0% to 44.5%), GDx had the lowest sensitivity (64.7%, 95% CI 60.7% to 68.7%) but the highest specificity (53.6%, 95% CI 48.2% to 58.9%). Introducing a composite triage station into the referral pathway to identify appropriate referrals was cost-effective. All triage strategies resulted in a cost reduction compared with standard care (consultant-led diagnosis) but with an associated reduction in effectiveness. GDx was the least costly and least effective strategy. OCT and HRT-GPS were not cost-effective. Compared with GDx, the cost per QALY gained for HRT-MRA is ÂŁ22,904. The cost per QALY gained with current practice is ÂŁ156,985 compared with HRT-MRA. Large savings could be made by implementing HRT-MRA but some benefit to patients will be forgone. The results were sensitive to the triage costs. CONCLUSIONS: Automated imaging can be effective to aid glaucoma diagnosis among individuals referred from the community to hospital eye services. A model of care using a triage composite test appears to be cost-effective

    The INTRABEAMÂŽ Photon Radiotherapy System for the adjuvant treatment of early breast cancer: a systematic review and economic evaluation

    Full text link

    Visor estereoscòpic amb mirall

    No full text
    ferro, vidre, caixa de fustaUlleres estereoscòpiques utilitzades per la interpretació de fotografies aèries. - Dins d'una caixa de fusta

    Telèmetre òptic

    No full text
    LlautóTelèmetre òptic de campanya o telèmetre de coincidència. S’utilitzava per trobar la distància d’objectes situats a pocs kilòmetres. També s’utilitza en treballs de topografia senzills, on no cal gaire precisió.Telèmetre d’inversió. B = 0.70 m. A = 11x85 x 11.5 c
    • …
    corecore