92 research outputs found

    A model for reactive porous transport during re-wetting of hardened concrete

    Full text link
    A mathematical model is developed that captures the transport of liquid water in hardened concrete, as well as the chemical reactions that occur between the imbibed water and the residual calcium silicate compounds residing in the porous concrete matrix. The main hypothesis in this model is that the reaction product -- calcium silicate hydrate gel -- clogs the pores within the concrete thereby hindering water transport. Numerical simulations are employed to determine the sensitivity of the model solution to changes in various physical parameters, and compare to experimental results available in the literature.Comment: 30 page

    Downsizing a human inflammatory protein to a small molecule with equal potency and functionality

    Get PDF
    A significant challenge in chemistry is to rationally reproduce the functional potency of a protein in a small molecule, which is cheaper to manufacture, non-immunogenic, and also both stable and bioavailable. Synthetic peptides corresponding to small bioactive protein surfaces do not form stable structures in water and do not exhibit the functional potencies of proteins. Here we describe a novel approach to growing small molecules with protein-like potencies from a functionally important amino acid of a protein. A 77-residue human inflammatory protein (complement C3a) important in innate immunity is rationally transformed to equipotent small molecules, using peptide surrogates that incorporate a turn-inducing heterocycle with correctly positioned hydrogen-bond-accepting atoms. Small molecule agonists (molecular weigh

    Vitamin D (1,25(OH

    Get PDF
    Studies to identify novel immune-regulatory functions of active vitamin D (1,25(OH) D3) in human CD4 T cells revealed that 1,25(OH) D3 potently induced expression of the gene SERPINA1, encoding the anti-protease α-1-antitrypsin. We confirmed α-1-antitrypsin protein expression by 1,25(OH) D3-treated CD4 T cells, but not in CD8 T cells or monocytes. α-1-Antitrypsin promotes anti-inflammatory IL-10 synthesis in other immune cell populations. We therefore investigated its immune-regulatory effects in CD4 T cells. Plasma-derived α-1-antitrypsin drove IL-10 synthesis by CD4 T cells, which was not dependent on anti-protease activity, but appeared to require a serum-binding factor, since this could not be achieved with recombinant protein. α-1-Antitrypsin is reported to bind complement components, which regulate T cell function. A role for this interaction was therefore probed. Plasma-derived, but not recombinant α-1-antitrypsin contained C3a. Surface Plasmon Resonance and Microscale Thermophoresis demonstrated α-1-antitrypsin binding to C3a. Addition of C3a to CD4 T cells cultured with recombinant α-1-antitrypsin restored induction of IL-10, whereas neutralisation of C3a abrogated IL-10 induced by plasma-derived α-1-antitrypsin. To interrogate an endogenous role for the α-1-antitrypsin-C3a axis in 1,25(OH) D3-driven CD4 T cell IL-10 synthesis, we treated cells from healthy or α-1-antitrypsin-deficient individuals (which transcribe SERPINA1 but do not secrete protein) with 1,25(OH) D3. A significant correlation was identified between SERPINA1 and IL10 gene expression in healthy donor CD4 T cells, which was absent in cells from α-1-antitrypsin-deficient individuals. Therefore, α-1-antitrypsin is required for 1,25(OH) D3-induced IL-10 expression in CD4 T cells, interacting with C3a to drive IL-10 expression. [Abstract copyright: Copyright © 2019. Published by Elsevier Ltd.

    Energy and Environmental Performance of Multi-Story Apartment Buildings Built in Timber Construction Using Passive House Principles

    No full text
    This paper presents energy and environmental performance analyses, a study of summer indoor temperatures and occupant behavior for an eight story apartment building, with the goal to combine high energy efficiency with low environmental impact, at a reasonable cost. Southern Portvakten building is built with prefabricated timber elements using passive house principles in the North European climate. Energy performance was analyzed through parametric studies, as well as monitored energy data, and complemented with analysis of occupant behavior during one year. Results show that airtight, low-energy apartment buildings can be successfully built with prefabricated timber elements in a cold climate. The monitored total energy use was 47.6 kWh/m2, excluding household electricity (revised to a normal year), which is considerably lower than of a standard building built today in Sweden—90 kWh/m2. However, the occupancy level was low during the analyzed year, which affects the energy use compared to if the building had been fully occupied. Environmental analysis shows that the future challenges lie in lowering the household and common electricity use, as well as in improving the choices of materials. More focus should also lie on improving occupant behavior and finding smart solar shading solutions for apartment buildings

    Energieffektivisering av referenskvarteret Trondheim inom JĂ€rvalyftet

    No full text
    Den ursprungliga lösningen som föreslogs av Svenska BostÀder för renoveringen av referensbyggnaden i omrÄdet Trondheim halverar byggnadens uppvÀrmningsbehov. Denna studie visar att genom ytterligare förfining av detaljerna vid planeringen av renoveringen, kan byggnadens uppvÀrmningsbehov ytterligare halveras jÀmfört med föreslagen renovering. Studien visar att enbart genom smÄ förÀndringar i utformningen av byggnaden kan denna förbÀttring uppnÄs. Störst förbÀttringspotential fÄr man om lufttÀthet och en effektiv vÀrmevÀxling i ventilationen Ästadkoms, dÀrefter kommer förbÀttringar av klimatskalet sÄsom förbÀttrad isolering, fönster och dörrar. Om renoveringen tar steget fullt ut mot en passivhusnivÄ blir det slutliga uppvÀrmningsbehovet bara en tiondel jÀmfört med idag. Delar som ocksÄ förbÀttras med framförallt ett bÀttre klimatskal Àr den termiska komforten. Tidigare undersökningar visar att mÄnga klagar pÄ att det Àr för kallt i motsvarande hus som kv. TrondheimDen ursprungliga lösningen som föreslogs av Svenska BostÀder för renoveringen av referensbyggnaden i omrÄdet Trondheim halverar byggnadens uppvÀrmningsbehov. Denna studie visar att genom ytterligare förfining av detaljerna vid planeringen av renoveringen, kan byggnadens uppvÀrmningsbehov ytterligare halveras jÀmfört med föreslagen renovering. Studien visar att enbart genom smÄ förÀndringar i utformningen av byggnaden kan denna förbÀttring uppnÄs. Störst förbÀttringspotential fÄr man om lufttÀthet och en effektiv vÀrmevÀxling i ventilationen Ästadkoms, dÀrefter kommer förbÀttringar av klimatskalet sÄsom förbÀttrad isolering, fönster och dörrar. Om renoveringen tar steget fullt ut mot en passivhusnivÄ blir det slutliga uppvÀrmningsbehovet bara en tiondel jÀmfört med idag. Delar som ocksÄ förbÀttras med framförallt ett bÀttre klimatskal Àr den termiska komforten. Tidigare undersökningar visar att mÄnga klagar pÄ att det Àr för kallt i motsvarande hus som kv. Trondhei

    Multi-stakeholder dialogue on green urban climate adaptation

    No full text
    This report is part of the project GreenClimeAdapt – Green Tools for Urban Climate Adaptation. The project is running 2009- 2013 in Malmö, Sweden, and is co-financed by the European Union LIFE+. The objectives of GreenClimeAdapt are to demonstrate climate adaptation in urban areas using open green storm water systems with increased biodiversity and recreation value, green facades and green roofs. The project and its full-scale demonstrations have been implemented in the City of Malmö, Sweden. As the rest of Northern Europe, in recent years, Malmö has experienced problems with increased precipitation and local flooding, which has already caused significant material losses and remediation costs.A

    Framtidens trĂ€hus— energieffektiva med god innemiljö.

    No full text
    Documentation of project's development, planning, and building phases. Building's energy performance.The report presents documentation of the critical points during the development, planning, and building phases of the first multi-storey apartment buildings built in timber prefabricated construction according to the voluntary Swedish passive house criteria. Besides choice of the construction details, building elements, and technical systems the report includes results from blower-door tests as well as the energy analysis of building's heating needs and achieved summer indoor temperatures. Finally a comparison was done with a reference building Limnologen, which was built according to the energy requirements in the VÀlle Broar area in VÀxjö. Simulations show that the Southern Portvakten building has 33% less power need for heating than if the same building was built as the Limnologen building, while the heating demand is 41% lower. A program for following the energy performance of the building during the first year in operation is also presented. Energy simulations were done in the DEROBLTH program.Documentation of project's development, planning, and building phases. Building's energy performance.The report presents documentation of the critical points during the development, planning, and building phases of the first multi-storey apartment buildings built in timber prefabricated construction according to the voluntary Swedish passive house criteria. Besides choice of the construction details, building elements, and technical systems the report includes results from blower-door tests as well as the energy analysis of building's heating needs and achieved summer indoor temperatures. Finally a comparison was done with a reference building Limnologen, which was built according to the energy requirements in the VÀlle Broar area in VÀxjö. Simulations show that the Southern Portvakten building has 33% less power need for heating than if the same building was built as the Limnologen building, while the heating demand is 41% lower. A program for following the energy performance of the building during the first year in operation is also presented. Energy simulations were done in the DEROBLTH program

    Framtidens trÀhus - energieffektiva med god innemiljö

    No full text
    I projektet "Framtidens TrĂ€hus - Energieffektiva med god innemiljö" har IVL som mĂ„l att miljömĂ€ssigt utveckla och utvĂ€rdera energieffektiva och sunda bostĂ€der i trĂ€ genom att delta i uppförandet av Kvarteret Portvakten i VĂ€xjö frĂ„n idĂ©stadium via byggnation och idrifttagning. Portvakten har kombinerat trĂ€byggnadsteknik med koncept för mycket lĂ„g energianvĂ€ndning, och tvĂ„ byggnader som Ă€gs av HyresbostĂ€der i VĂ€xjö har uppförts med tekniken. Inom detta projekt analyserades byggnad (A1), som ligger pĂ„ den nordvĂ€stra delen av byggplatsen som kallas Portvakten Söder. Tidigare har rapporten " Framtidens trĂ€hus – energieffektiva med god innemiljö. Documentation of project’s development, planning, and building phases. Building’s energy performance " publicerats som beskriver projektets utvecklings-, planerings- och byggfaser. I denna rapport redovisas uppföljningen av byggnad (A1) med kvalitativa och kvantitativa analyser av uppmĂ€tta energiprestanda, brukar- och drifterfarenheter samt berĂ€kning av byggnadens miljöprestanda genom livscykelanalys (LCA) med verkliga driftdata. Även byggnad B1 har analyserats för uppmĂ€tt energiprestanda samt brukar- och drifterfarenheter för att kunna jĂ€mföra med resultaten frĂ„n byggnaden A1. I energiprestandan har energianvĂ€ndning uppmĂ€tts för uppvĂ€rmning, varmvattenanvĂ€ndning, elanvĂ€ndning (hushĂ„lls- och fastighetsel), Ă„tervunnen energi frĂ„n avloppsvattenvĂ€rmevĂ€xlaren och inomhustemperaturen registrerats i nĂ„gra representativa lĂ€genheter. Under den analyserade perioden var den uppmĂ€tta energianvĂ€ndningen för uppvĂ€rmning (normaliserad) mer Ă€n dubbel sĂ„ hög jĂ€mfört med berĂ€knade vĂ€rden (22,2 kWh/m2 jĂ€mfört med 8,9 kWh/m2). Förklaringen tros ligga i injusteringsproblem av tekniska system, lĂ„g uthyrningsgrad och hur brukarna nyttjat lĂ€genheterna under den analyserade perioden. Den köpta volymen av tappvarmvatten Ă€r nĂ€stan hĂ€lften av svenska genomsnittet för 2009, vilket Ă€r i linje med den berĂ€knade mĂ€ngden som ges i de svenska frivilliga passivhuskriterierna [12]. Om uppmĂ€tt energianvĂ€ndning för uppvĂ€rmning och varmvatten justeras till 100% uthyrningsgrad motsvarar denna siffra en fjĂ€rdedel av den energi som anvĂ€nds i ett genomsnittligt svenskt flerfamiljshus (under perioden 2005-2009) [27]. Fastighetsel, som förutom el för belysning av gemensamma utrymmen och hiss inbegriper el för flĂ€ktar och pumpar, utgör en betydande post, motsvarande nĂ€stan 20% av den totala energi som anvĂ€nds i byggnaden A1. Under den analyserade perioden motsvarar det dubbelt sĂ„ mycket jĂ€mfört med rekommendationerna i de svenska frivilliga passivhuskriterierna.  Inomhustemperaturer under sommarperioden, vilket var ett bekymmer under projektets utvecklingsfas, visade goda resultat under mĂ€tperioden. Inomhustemperaturen var jĂ€mn i de övervakade lĂ€genheterna oavsett deras lĂ€ge och belĂ€ggning (uthyrningsgrad). Effektiviteten av avloppsvĂ€rmevĂ€xlaren kunde inte bedömas pĂ„ grund av den lĂ„ga uthyrningsgraden av huset. Den totala viktade köpta energin i Portvakten Söder var 61,1 kWh/m2a (Byggnad A1) och 45 kWh/m2a (Byggnad B1), vilket var lĂ€gre för bĂ„da byggandera jĂ€mfört med andra energisnĂ„la flerbostadshus, som VĂ€rnamo, FrillesĂ„s, Lidköping, och de renoverade lĂ€genheterna i BrogĂ„rden i AlingsĂ„s. Skillnaden i uppmĂ€tt energiprestanda mellan byggnaderna A1 och B2 kan förklaras av hur elanvĂ€ndningen för fastighetselen i de tvĂ„ byggnaderna mĂ€ts. ElmĂ€taren för fastighetselen i byggnaden A1 registrerar Ă€ven el som anvĂ€nds i förrĂ„det (separat byggnad) dĂ€r pumpar för vattencirkulationen för bĂ„da byggnaderna Ă€r belĂ€gna. Livscykelanalysen av Portvakten Söders byggnad visar att den minskade energianvĂ€ndningen för uppvĂ€rmning gör att hushĂ„llselsanvĂ€ndning nu stĂ„r för den procentuellt största andelen av primĂ€renergianvĂ€ndningen sett pĂ„ 60 Ă„rs drift. En lösning skulle kunna vara att installera solceller för att minska denna miljöpĂ„verkan, men dĂ„ ska analysen ocksĂ„ inkludera miljöpĂ„verkan frĂ„n produktion och drift av solceller. Den minskade energianvĂ€ndningen för uppvĂ€rmning fĂ„r vidare effekten att den procentuella andelen av den totala miljöpĂ„verkan frĂ„n produktion av byggmaterial ökar. En slutsats frĂ„n utvĂ€rderingen Ă€r att analys av energiprestanda under första Ă„rets drift bör undvikas. Ytterligare en vintersĂ€song bör förlöpa för justering av system under en mer normal uthyrningsgrad av lĂ€genheter. Detta blir sĂ€rskilt viktigt för lĂ„genergihus dĂ€r energiĂ„tervinning frĂ„n mĂ€nniskor och apparater ingĂ„r i energikonceptet. Även avloppsvĂ€rmevĂ€xlaren krĂ€ver att byggnaden Ă€r fullt belagd för att kunna fungera optimalt.For the first time in Sweden an eight storey high building has been constructed in timber according to the voluntary Swedish passive house criteria. Within the Vinnova (the Swedish Governmental Agency for Innovation Systems) research project “Framtidens trĂ€hus – energieffektiva med god innemiljĂ¶â€ IVL has the aim to perform an environmental evaluation and document the development of the energy-efficient multi-family housing built in timber construction. Two buildings, built in VĂ€xjö, are owned by the Rental Housing Company in VĂ€xjö (“HyresbostĂ€der i VĂ€xjĂ¶â€). Only building A1 was analysed, which lies on the north-western part of the building site called Southern Portvakten (“Portvakten Söder”). In the first report “Framtidens trĂ€hus – energieffektiva med god innemiljö. Documentation of project’s development, planning, and building phases. Building’s energy performance” [1] the project’s development, planning, and building phases were presented. In this report, results of the qualitative and quantitative evaluation of the Southern Portvakten building in VĂ€xjö are presented. It includes results of the evaluation of the measured energy performance, user and operational experiences during the first year in operation, as well as the building’s environmental performance analysed with LCA

    Kunskapsinventering avseende resurseffektiviserande ÄtgÀrder inom befintlig bebyggelse

    No full text
    Rapporten sammanfattar kunskapslÀget för olika renoveringsÄtgÀrder i flerbostadshus byggda mellan 1941-1980. Potentialen för renovering har berÀknats ge en halverad energianvÀndning för uppvÀrmning och varmvatten. Denna effektivisering Àr dock ansedd som möjlig, men inte trolig. Det finns mÄnga fallstudier av enskilda projekt med teoretiska berÀkningar av renoveringspotentialen för olika ÄtgÀrder. Det finns relativt mÄnga generella studier för bostadsbestÄndet i stort dÀr potentialen för olika ÄtgÀrder har berÀknats för hela Sverige men fÄ studier av verkliga genomförda projekt. Bindande minimikrav kopplat till energiprestandadirektivet för byggnader för renovering har införts i ett flertal andra lÀnder inom EU vilket ocksÄ konstateras bidra till att mer energieffektiva ÄtgÀrder införs i större renoveringsprojekt. De viktigaste ÄtgÀrderna som vi har funnit Àr införande av FTX-system, renovering av klimatskalet samt individuell mÀtning och debitering av vÀrme och varmvatte
    • 

    corecore