10 research outputs found

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Full text link
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).Comment: 48 pages, 29 figures, Accepted for publication in Experimental Astronomy with minor editin

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Get PDF
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory. Athena is a versatile observatory designed to address the Hot and Energetic Universe science theme, as selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), X-IFU aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over a hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR (i.e. in the course of its preliminary definition phase, so-called B1), browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters, such as the instrument efficiency, spectral resolution, energy scale knowledge, count rate capability, non X-ray background and target of opportunity efficiency. Finally, we briefly discuss the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, touch on communication and outreach activities, the consortium organisation and the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with ESA member state contributions from Belgium, Czech Republic, Finland, Germany, Poland, Spain, Switzerland, with additional contributions from the United States and Japan.The French contribution to X-IFU is funded by CNES, CNRS and CEA. This work has been also supported by ASI (Italian Space Agency) through the Contract 2019-27-HH.0, and by the ESA (European Space Agency) Core Technology Program (CTP) Contract No. 4000114932/15/NL/BW and the AREMBES - ESA CTP No.4000116655/16/NL/BW. This publication is part of grant RTI2018-096686-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. This publication is part of grant RTI2018-096686-B-C21 and PID2020-115325GB-C31 funded by MCIN/AEI/10.13039/501100011033

    Does Very Poor Performance Status Systematically Preclude Single Agent Anti-PD-1 Immunotherapy? A Multicenter Study of 35 Consecutive Patients

    No full text
    International audienceAnti-PD-1 antibodies prolong survival of performance status (PS) 0–1 advanced non-small-cell lung cancer (aNSCLC) patients. Their efficacy in PS 3–4 patients is unknown. Conse- cutive PS 3–4 aNSCLC patients receiving compassionate nivolumab were accrued by 12 French thoracic oncology departments, over 24 months. Overall survival (OS) was calculated using the Kaplan-Meier method. Prognostic variables were assessed using Cox proportional hazards models. Overall, 35 PS 3–4 aNSCLC patients (median age 65 years) received a median of 4 nivolumab infusions (interquartile range [IQR], 1–7) as first- (n = 6) or second-line (n = 29) therapy. At a median of 52-month follow-up (95%CI, 41–63), 32 (91%) patients had died. Median progression-free survival was 2.1 months (95%CI, 1.1–3.2). Median OS was 4.4 months (95%CI, 0.5–8.2). Overall, 20% of patients were alive at 1 year, and 14% at 2 years. Treatment-related adverse events occurred in 8/35 patients (23%), mostly of low-grade. After adjustment, brain metastases (HR = 5.2; 95%CI, 9–14.3, p = 0.001) and <20 pack-years (HR = 4.8; 95%CI, 1.7–13.8, p = 0.003) predicted worse survival. PS improvement from 3–4 to 0–1 (n = 9) led to a median 43-month (95%CI, 0–102) OS. Certain patients with very poor general condition could derive long-term benefit from nivolumab salvage therapy

    Long-term effectiveness and treatment sequences in patients with extensive stage small cell lung cancer receiving atezolizumab plus chemotherapy: Results of the IFCT-1905 CLINATEZO real-world study

    No full text
    International audienceBackground: Small cell lung cancer (SCLC) has a tendency towards recurrence and limited survival. Standard-of-care in 1st-line is platinum-etoposide chemotherapy plus atezolizumab or durvalumab, based on landmark clinical trials. Methods: IFCT-1905 CLINATEZO is a nationwide, non-interventional, retrospective study of patients with extensive-SCLC receiving atezolizumab plus chemotherapy as part of French Early Access Program. Objectives were to analyse effectiveness, safety and subsequent treatments. Results: The population analyzed included 518 patients who received atezolizumab in 65 participating centers. There were 66.2% male, mean age was 65.7 years; 89.1% had a performance status (PS) 0/1 and 26.6% brain metastases. Almost all (95.9%) were smokers. Fifty-five (10.6%) received at least 1 previous treatment. Median number of atezolizumab injections was 7.0 (range [1.0–48.0]) for a median duration of 4.9 months (95% CI 4.5–5.1). Atezolizumab was continued beyond progression in 122 patients (23.6%) for a median duration of 1.9 months (95% CI: [1.4–2.3]). Best objective response was complete and partial in 19 (3.9%) and 378 (77.1%) patients. Stable disease was observed in 50 patients (10.2%). Median follow-up was 30.8 months (95% CI: [29.9–31.5]). Median overall survival (OS), 12-, 24-month OS rates were 11.3 months (95% CI: [10.1–12.4]), 46.7% (95% CI [42.3–50.9]) and 21.2% (95% CI [17.7–24.8]). Median real-world progression-free survival, 6-, 12-month rates were 5.2 months (95% CI [5.0–5.4]), 37.5% (95% CI [33.3–41.7]) and 15.2% (95% CI [12.2–18.6]). For patients with PS 0/1, median OS was 12.2 months (95% CI [11.0–13.5]). For patients with previous treatment, median OS was 14.9 months (95% CI [10.1–21.5]). Three-hundred-and-twenty-six patients (66.4%) received subsequent treatment and 27 (5.2%) were still under atezolizumab at date of last news. Conclusions: IFCT-1905 CLINATEZO shows reproductibility, in real-life, of IMpower-133 survival outcomes, possibly attributed to selection of patients fit for this regimen, adoption of pragmatic approaches, including concurrent radiotherapy and treatment beyond progression

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    No full text
    48 pages, 29 figures, submitted for publication in Experimental AstronomyThe Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. It is expected that thanks to the studies conducted so far on X-IFU, along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained (abridged)

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Get PDF
    48 pages, 29 figures, submitted for publication in Experimental AstronomyThe Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. It is expected that thanks to the studies conducted so far on X-IFU, along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained (abridged)
    corecore