61 research outputs found

    Robust Online Hamiltonian Learning

    Get PDF
    In this work we combine two distinct machine learning methodologies, sequential Monte Carlo and Bayesian experimental design, and apply them to the problem of inferring the dynamical parameters of a quantum system. We design the algorithm with practicality in mind by including parameters that control trade-offs between the requirements on computational and experimental resources. The algorithm can be implemented online (during experimental data collection), avoiding the need for storage and post-processing. Most importantly, our algorithm is capable of learning Hamiltonian parameters even when the parameters change from experiment-to-experiment, and also when additional noise processes are present and unknown. The algorithm also numerically estimates the Cramer-Rao lower bound, certifying its own performance.Comment: 24 pages, 12 figures; to appear in New Journal of Physic

    Epidemiology, practice of ventilation and outcome for patients at increased risk of postoperative pulmonary complications

    Get PDF
    BACKGROUND Limited information exists about the epidemiology and outcome of surgical patients at increased risk of postoperative pulmonary complications (PPCs), and how intraoperative ventilation was managed in these patients. OBJECTIVES To determine the incidence of surgical patients at increased risk of PPCs, and to compare the intraoperative ventilation management and postoperative outcomes with patients at low risk of PPCs. DESIGN This was a prospective international 1-week observational study using the ‘Assess Respiratory Risk in Surgical Patients in Catalonia risk score’ (ARISCAT score) for PPC for risk stratification. PATIENTS AND SETTING Adult patients requiring intraoperative ventilation during general anaesthesia for surgery in 146 hospitals across 29 countries. MAIN OUTCOME MEASURES The primary outcome was the incidence of patients at increased risk of PPCs based on the ARISCAT score. Secondary outcomes included intraoperative ventilatory management and clinical outcomes. RESULTS A total of 9864 patients fulfilled the inclusion criteria. The incidence of patients at increased risk was 28.4%. The most frequently chosen tidal volume (VT) size was 500 ml, or 7 to 9 ml kg1 predicted body weight, slightly lower in patients at increased risk of PPCs. Levels of positive end-expiratory pressure (PEEP) were slightly higher in patients at increased risk of PPCs, with 14.3% receiving more than 5 cmH2O PEEP compared with 7.6% in patients at low risk of PPCs (P < 0.001). Patients with a predicted preoperative increased risk of PPCs developed PPCs more frequently: 19 versus 7%, relative risk (RR) 3.16 (95% confidence interval 2.76 to 3.61), P < 0.001) and had longer hospital stays. The only ventilatory factor associated with the occurrence of PPCs was the peak pressure. CONCLUSION The incidence of patients with a predicted increased risk of PPCs is high. A large proportion of patients receive high VT and low PEEP levels. PPCs occur frequently in patients at increased risk, with worse clinical outcome

    Epidemiology, practice of ventilation and outcome for patients at increased risk of postoperative pulmonary complications: LAS VEGAS - An observational study in 29 countries

    Get PDF
    BACKGROUND Limited information exists about the epidemiology and outcome of surgical patients at increased risk of postoperative pulmonary complications (PPCs), and how intraoperative ventilation was managed in these patients. OBJECTIVES To determine the incidence of surgical patients at increased risk of PPCs, and to compare the intraoperative ventilation management and postoperative outcomes with patients at low risk of PPCs. DESIGN This was a prospective international 1-week observational study using the ‘Assess Respiratory Risk in Surgical Patients in Catalonia risk score’ (ARISCAT score) for PPC for risk stratification. PATIENTS AND SETTING Adult patients requiring intraoperative ventilation during general anaesthesia for surgery in 146 hospitals across 29 countries. MAIN OUTCOME MEASURES The primary outcome was the incidence of patients at increased risk of PPCs based on the ARISCAT score. Secondary outcomes included intraoperative ventilatory management and clinical outcomes. RESULTS A total of 9864 patients fulfilled the inclusion criteria. The incidence of patients at increased risk was 28.4%. The most frequently chosen tidal volume (V T) size was 500 ml, or 7 to 9 ml kg−1 predicted body weight, slightly lower in patients at increased risk of PPCs. Levels of positive end-expiratory pressure (PEEP) were slightly higher in patients at increased risk of PPCs, with 14.3% receiving more than 5 cmH2O PEEP compared with 7.6% in patients at low risk of PPCs (P ˂ 0.001). Patients with a predicted preoperative increased risk of PPCs developed PPCs more frequently: 19 versus 7%, relative risk (RR) 3.16 (95% confidence interval 2.76 to 3.61), P ˂ 0.001) and had longer hospital stays. The only ventilatory factor associated with the occurrence of PPCs was the peak pressure. CONCLUSION The incidence of patients with a predicted increased risk of PPCs is high. A large proportion of patients receive high V T and low PEEP levels. PPCs occur frequently in patients at increased risk, with worse clinical outcome.</p

    EpiDex® Swiss field trial 2004-2008

    Full text link
    BACKGROUND: Approximately 20% of leg ulcers remain unresponsive to the best conservative standard of care. So far, these patients could either receive conventional skin grafts or had to accept their intractable wound. Skin substitutes from cell culture may represent a promising alternative to heal a major part of these patients on a non-surgical, potentially more cost-effective basis. OBJECTIVE: To systematically evaluate the first 68 patients treated in Switzerland (Swiss EpiDex® field trial 2004-2008). METHODS: Retrospective study on EpiDex treatment of a complete consecutive series of 68 patients with chronic wounds (66 chronic leg ulcers, 2 sores) unresponsive to best conservative standard of care. The primary end point was complete wound closure within 9 months after transplantation, the secondary end points change of wound surface area, pain reduction and overall judgement by the patient. Adverse effects were infection, dermatitis and others. Calculation of treatment costs was made. RESULTS: By the end of the study, 50/68 (74%) of patients had their wound completely healed [venous 29/37 (78%); mixed 7/9 (78%); others 14/22 (64%)]; 10/68 (15%) had the wound surface area reduced by >50%, and 8/68 (12%) did not respond to the EpiDex treatment. Wound pain disappeared completely in 78% and partially in 13%. Fifteen patients (22%) received antibiotics for wound infection, and 2 (3%) developed dermatitis (not related to the local therapy). Average treatment costs for venous ulcers amounted to EUR 5,357, compared to EUR 5,722-8,622 reimbursed according to the German DRG system (2010) for an in-patient skin graft. CONCLUSION: EpiDex may effectively heal up to three quarters of recalcitrant chronic leg ulcers. Thus, it represents an intermediate step to avoid costly in-patient split-skin mesh graft treatments. Patients remain mobilized, and a donor site is avoided. Large wound size or a necrotic wound bed limit the use of EpiDex. Otherwise, it offers the opportunity to avoid conventional skin grafts in a significant number of chronic leg ulcer patients. Copyright © 2010 S. Karger AG, Basel

    Design and implementation of the numachine multiprocessor

    No full text
    This paper describes the design and implementation of the NUMAchine multiprocessor. As the market for CC-NUMA multiprocessors expands, this research project provides a timely architectural design and cost-effective prototype. The key to the successful implementation of our 48-processor prototype is the use of off-the-shelf components and programmable logic devices. Since this machine will serve as a research vehicle for parallel software development, a number of hardware features to enhance experimentation have been included in the design.
    corecore