97 research outputs found

    Covid-19 has redefined airborne transmission

    Get PDF

    What is the risk of acquiring SARS-CoV-2 from the use of public toilets?

    Get PDF
    Public toilets and bathrooms may act as a contact hub point where community transmission of SARS-CoV-2 occurs between users. The mechanism of spread would arise through three mechanisms: inhalation of faecal and/or urinary aerosol from an individual shedding SARS-CoV-2; airborne transmission of respiratory aerosols between users face-to-face or during short periods after use; or from fomite transmission via frequent touch sites such as door handles, sink taps, lota or toilet roll dispenser. In this respect toilets could present a risk comparable with other high throughput enclosed spaces such as public transport and food retail outlets. They are often compact, inadequately ventilated, heavily used and subject to maintenance and cleaning issues. Factors such as these would compound the risks generated by toilet users incubating or symptomatic with SARS-CoV-2. Furthermore, toilets are important public infrastructure since they are vital for the maintenance of accessible, sustainable and comfortable urban spaces. Given the lack of studies on transmission through use of public toilets, comprehensive risk assessment relies upon the compilation of evidence gathered from parallel studies, including work performed in hospitals and prior work on related viruses. This narrative review examines the evidence suggestive of transmission risk through use of public toilets and concludes that such a risk cannot be lightly disregarded. A range of mitigating actions are suggested for both users of public toilets and those that are responsible for their design, maintenance and management

    Practical Indicators for Risk of Airborne Transmission in Shared Indoor Environments and Their Application to COVID-19 Outbreaks

    Get PDF
    Some infectious diseases, including COVID-19, can undergo airborne transmission. This may happen at close proximity, but as time indoors increases, infections can occur in shared room air despite distancing. We propose two indicators of infection risk for this situation, that is, relative risk parameter (Hr) and risk parameter (H). They combine the key factors that control airborne disease transmission indoors: viruscontaining aerosol generation rate, breathing flow rate, masking and its quality, ventilation and aerosol-removal rates, number of occupants, and duration of exposure. COVID-19 outbreaks show a clear trend that is consistent with airborne infection and enable recommendations to minimize transmission risk. Transmission in typical prepandemic indoor spaces is highly sensitive to mitigation efforts. Previous outbreaks of measles, influenza, and tuberculosis were also assessed. Measles outbreaks occur at much lower risk parameter values than COVID-19, while tuberculosis outbreaks are observed at higher risk parameter values. Because both diseases are accepted as airborne, the fact that COVID-19 is less contagious than measles does not rule out airborne transmission. It is important that future outbreak reports include information on masking, ventilation and aerosol-removal rates, number of occupants, and duration of exposure, to investigate airborne transmission

    Finite volume simulation of 2-D steady square lid driven cavity flow at high reynolds numbers

    Get PDF
    In this work, computer simulation results of steady incompressible flow in a 2-D square lid-driven cavity up to Reynolds number (Re) 65000 are presented and compared with those of earlier studies. The governing flow equations are solved by using the finite volume approach. Quadratic upstream interpolation for convective kinematics (QUICK) is used for the approximation of the convective terms in the flow equations. In the implementation of QUICK, the deferred correction technique is adopted. A non-uniform staggered grid arrangement of 768x768 is employed to discretize the flow geometry. Algebraic forms of the coupled flow equations are then solved through the iterative SIMPLE (Semi-Implicit Method for Pressure-Linked Equation) algorithm. The outlined computational methodology allows one to meet the main objective of this work, which is to address the computational convergence and wiggled flow problems encountered at high Reynolds and Peclet (Pe) numbers. Furthermore, after Re > 25000 additional vortexes appear at the bottom left and right corners that have not been observed in earlier studies

    Dismantling myths on the airborne transmission of severe acute respiratory syndrome coronavirus (SARS-CoV-2)

    Get PDF
    The Covid-19 pandemic has caused untold disruption and enhanced mortality rates around the world. Understanding the mechanisms for transmission of SARS-CoV-2 is key to preventing further spread but there is confusion over the meaning of “airborne” whenever transmission is discussed. Scientific ambivalence originates from evidence published many years ago, which has generated mythological beliefs that obscure current thinking. This article gathers together and explores some of the most commonly held dogmas on airborne transmission in order to stimulate revision of the science in the light of current evidence. Six ‘myths’ are presented, explained, and ultimately refuted on the basis of recently published papers and expert opinion from previous work related to similar viruses. There is little doubt that SARS-CoV-2 is transmitted via a range of airborne particle sizes subject to all the usual ventilation parameters and human behaviour. Experts from specialties encompassing aerosol studies, ventilation, engineering, physics, virology and clinical medicine have joined together to present this review, in order to consolidate the evidence for airborne transmission mechanisms and offer justification for modern strategies for prevention and control of Covid-19 in healthcare and community

    Warm Body Temperature Facilitates Energy Efficient Cortical Action Potentials

    Get PDF
    The energy efficiency of neural signal transmission is important not only as a limiting factor in brain architecture, but it also influences the interpretation of functional brain imaging signals. Action potential generation in mammalian, versus invertebrate, axons is remarkably energy efficient. Here we demonstrate that this increase in energy efficiency is due largely to a warmer body temperature. Increases in temperature result in an exponential increase in energy efficiency for single action potentials by increasing the rate of Na+ channel inactivation, resulting in a marked reduction in overlap of the inward Na+, and outward K+, currents and a shortening of action potential duration. This increase in single spike efficiency is, however, counterbalanced by a temperature-dependent decrease in the amplitude and duration of the spike afterhyperpolarization, resulting in a nonlinear increase in the spike firing rate, particularly at temperatures above approximately 35°C. Interestingly, the total energy cost, as measured by the multiplication of total Na+ entry per spike and average firing rate in response to a constant input, reaches a global minimum between 37–42°C. Our results indicate that increases in temperature result in an unexpected increase in energy efficiency, especially near normal body temperature, thus allowing the brain to utilize an energy efficient neural code
    corecore