141 research outputs found

    Guided and magnetic self-assembly of tunable magnetoceptive gels

    Get PDF
    Self-assembly of components into complex functional patterns at microscale is common in nature, and used increasingly in numerous disciplines such as optoelectronics, microfabrication, sensors, tissue engineering and computation. Here, we describe the use of stable radicals to guide the self-assembly of magnetically tunable gels, which we call ‘magnetoceptive’ materials at the scale of hundreds of microns to a millimeter, each can be programmed by shape and composition, into heterogeneous complex structures. Using paramagnetism of free radicals as a driving mechanism, complex heterogeneous structures are built in the magnetic field generated by permanent magnets. The overall magnetic signature of final structure is erased via an antioxidant vitamin E, subsequent to guided self-assembly. We demonstrate unique capabilities of radicals and antioxidants in fabrication of soft systems with heterogeneity in material properties, such as porosity, elastic modulus and mass density; then in bottom-up tissue engineering and finally, levitational and selective assembly of microcomponents

    Evidence for muon neutrino oscillation in an accelerator-based experiment

    Get PDF
    We present results for muon neutrino oscillation in the KEK to Kamioka (K2K) long-baseline neutrino oscillation experiment. K2K uses an accelerator-produced muon neutrino beam with a mean energy of 1.3 GeV directed at the Super-Kamiokande detector. We observed the energy dependent disappearance of muon neutrino, which we presume have oscillated to tau neutrino. The probability that we would observe these results if there is no neutrino oscillation is 0.0050% (4.0 sigma).Comment: 5 pages, 4 figure

    Search for sterile neutrino oscillation using RENO and NEOS data

    Full text link
    We present a reactor model independent search for sterile neutrino oscillation using 2\,509\,days of RENO near detector data and 180 days of NEOS data. The reactor related systematic uncertainties are significantly suppressed as both detectors are located at the same reactor complex of Hanbit Nuclear Power Plant. The search is performed by electron antineutrino\,(νe\overline{\nu}_e) disappearance between six reactors and two detectors with baselines of 294\,m\,(RENO) and 24\,m\,(NEOS). A spectral comparison of the NEOS prompt-energy spectrum with a no-oscillation prediction from the RENO measurement can explore reactor νe\overline{\nu}_e oscillations to sterile neutrino. Based on the comparison, we obtain a 95\% C.L. excluded region of 0.1<Δm412<70.1<|\Delta m_{41}^2|<7\,eV2^2. We also obtain a 68\% C.L. allowed region with the best fit of Δm412=2.41±0.03|\Delta m_{41}^2|=2.41\,\pm\,0.03\,\,eV2^2 and sin22θ14\sin^2 2\theta_{14}=0.08±\,\pm\,0.03 with a p-value of 8.2\%. Comparisons of obtained reactor antineutrino spectra at reactor sources are made among RENO, NEOS, and Daya Bay to find a possible spectral variation.Comment: 6 pages, 5 figures: This manuscript has been significantly revised by the joint reanalysis by RENO and NEOS Collaborations. (In the previous edition, the RENO collaboration used publicly available NEOS data to evaluate the expected neutrino spectrum at NEOS.

    Differences in the pattern and regulation of mineral deposition in human cell lines of osteogenic and non-osteogenic origin

    Get PDF
    Bone marrow-derived mesenchymal stem cells (MSCs) are widely used as a cellular model of bone formation, and can mineralize in vitro in response to osteogenic medium (OM). It is unclear, however, whether this property is specific to cells of mesenchymal origin. We analysed the OM response in 3 non-osteogenic lines, HEK293, HeLa and NTera, compared to MSCs. Whereas HEK293 cells failed to respond to OM conditions, the 2 carcinoma-derived lines NTera and HeLa deposited a calcium phosphate mineral comparable to that present in MSC cultures. However, unlike MSCs, HeLa and NTera cultures did so in the absence of dexamethasone. This discrepancy was confirmed, as bone morphogenetic protein inhibition obliterated the OM response in MSCs but not in HeLa or NTera, indicating that these 2 models can deposit mineral through a mechanism independent of established dexamethasone or bone morphogenetic protein signalling

    Abiraterone in metastatic prostate cancer without previous chemotherapy

    Get PDF
    Background: Abiraterone acetate, an androgen biosynthesis inhibitor, improves overall survival in patients with metastatic castration-resistant prostate cancer after chemotherapy. We evaluated this agent in patients who had not received previous chemotherapy. Methods: In this double-blind study, we randomly assigned 1088 patients to receive abiraterone acetate (1000 mg) plus prednisone (5 mg twice daily) or placebo plus prednisone. The coprimary end points were radiographic progression-free survival and overall survival. Results: The study was unblinded after a planned interim analysis that was performed after 43% of the expected deaths had occurred. The median radiographic progressionfree survival was 16.5 months with abiraterone - prednisone and 8.3 months with prednisone alone (hazard ratio for abiraterone - prednisone vs. prednisone alone, 0.53; 95% confidence interval [CI], 0.45 to 0.62; P<0.001). Over a median follow-up period of 22.2 months, overall survival was improved with abiraterone - prednisone (median not reached, vs. 27.2 months for prednisone alone; hazard ratio, 0.75; 95% CI, 0.61 to 0.93; P = 0.01) but did not cross the efficacy boundary. Abiraterone - prednisone showed superiority over prednisone alone with respect to time to initiation of cytotoxic chemotherapy, opiate use for cancer-related pain, prostate-specific antigen progression, and decline in performance status. Grade 3 or 4 mineralocorticoid-related adverse events and abnormalities on liver-function testing were more common with abiraterone-prednisone. Conclusions: Abiraterone improved radiographic progression-free survival, showed a trend toward improved overall survival, and significantly delayed clinical decline and initiation of chemotherapy in patients with metastatic castration-resistant prostate cancer

    Construction status and prospects of the Hyper-Kamiokande project

    Get PDF
    The Hyper-Kamiokande project is a 258-kton Water Cherenkov together with a 1.3-MW high-intensity neutrino beam from the Japan Proton Accelerator Research Complex (J-PARC). The inner detector with 186-kton fiducial volume is viewed by 20-inch photomultiplier tubes (PMTs) and multi-PMT modules, and thereby provides state-of-the-art of Cherenkov ring reconstruction with thresholds in the range of few MeVs. The project is expected to lead to precision neutrino oscillation studies, especially neutrino CP violation, nucleon decay searches, and low energy neutrino astronomy. In 2020, the project was officially approved and construction of the far detector was started at Kamioka. In 2021, the excavation of the access tunnel and initial mass production of the newly developed 20-inch PMTs was also started. In this paper, we present a basic overview of the project and the latest updates on the construction status of the project, which is expected to commence operation in 2027

    Prospects for neutrino astrophysics with Hyper-Kamiokande

    Get PDF
    Hyper-Kamiokande is a multi-purpose next generation neutrino experiment. The detector is a two-layered cylindrical shape ultra-pure water tank, with its height of 64 m and diameter of 71 m. The inner detector will be surrounded by tens of thousands of twenty-inch photosensors and multi-PMT modules to detect water Cherenkov radiation due to the charged particles and provide our fiducial volume of 188 kt. This detection technique is established by Kamiokande and Super-Kamiokande. As the successor of these experiments, Hyper-K will be located deep underground, 600 m below Mt. Tochibora at Kamioka in Japan to reduce cosmic-ray backgrounds. Besides our physics program with accelerator neutrino, atmospheric neutrino and proton decay, neutrino astrophysics is an important research topic for Hyper-K. With its fruitful physics research programs, Hyper-K will play a critical role in the next neutrino physics frontier. It will also provide important information via astrophysical neutrino measurements, i.e., solar neutrino, supernova burst neutrinos and supernova relic neutrino. Here, we will discuss the physics potential of Hyper-K neutrino astrophysics

    Evolution of hydrogen from magnesium alloy scraps in citric acid-added seawater without catalyst

    No full text
    This work employed a mixture of low-grade Mg scraps (LGMS) and citric acid-added seawater to generate hydrogen gas. Metal catalyst was not required for accelerating the reaction of H(2) generation in the Mg scraps/citric acid solution. LGMS in 20 wt% citric acid-added seawater could produce substantially higher H(2) volume than the LGMS in 5 wt% citric acid-added seawater. Purity of the generated H(2) was about 99% (after dehumidification). By filling H(2)-production reactor every 30 min with fresh seawater to which citric acid has been added, similar to 701 of hydrogen could be produced in 100 min. (C) 2009 International Association for Hydrogen Energy. Published by Elsevier Ltd. All rights reserved

    Effect of weight perception on human performance in a haptic-enabled virtual assembly platform

    No full text
    International audienceVirtual assembly platforms (VAPs) provide a means to interrogate product form, fit and function thereby shortening the design cycle time and improving product manufacturability while reducing assembly cost. VAPs lend themselves to training and can be used as offline programmable interfaces for planning and automation. Haptic devices are increasingly being chosen as the mode of interaction for VAPs over conventional glove-based and 3D-mice, the key benefit being the kinaesthetic feedback users receive while performing virtual assembly tasks in 2D/3D space leading to a virtual world closer to the real world. However, the challenge in recent years is to understand and evaluate the addedvalue of haptics. This paper reports on a haptic enabled VAP with a view to questioning the awareness of the environment and associated assembly tasks. The objective is to evaluate and compare humanperformance during virtual assembly and real-world assembly, and to identify conditions that may affect the performance of virtual assembly tasks. In particular, the effect of weight perception on virtual assembly tasks is investigated
    corecore