121 research outputs found

    Robust free space board-to-board optical interconnect with closed loop MEMS tracking

    Get PDF
    We present a free-space optical interconnect system capable of dynamic closed-loop optical alignment using a microlens scanner with a proportional integral and derivative controller. Electrostatic microlens scanners based on combdrive actuators are designed and characterized with vertical cavity surface emitting lasers (VCSELs) for adaptive optical beam tracking in the midst of mechanical vibration noise. The microlens scanners are fabricated on silicon-on-insulator wafers with a bulk micromachining process using deep reactive ion etching. We demonstrate dynamic optical beam positioning with a 700 Hz bandwidth and a maximum noise reduction of approximately 40 dB. Eye diagrams with a 1 Gb/s modulation rate are presented to demonstrate the improved optical link in the presence of mechanical noise

    Improving quality of care and outcome at very preterm birth: the Preterm Birth research programme, including the Cord pilot RCT

    Get PDF
    BACKGROUND: Being born very premature (i.e. before 32 weeks’ gestation) has an impact on survival and quality of life. Improving care at birth may improve outcomes and parents’ experiences. OBJECTIVES: To improve the quality of care and outcomes following very preterm birth. DESIGN: We used mixed methods, including a James Lind Alliance prioritisation, a systematic review, a framework synthesis, a comparative review, qualitative studies, development of a questionnaire tool and a medical device (a neonatal resuscitation trolley), a survey of practice, a randomised trial and a protocol for a prospective meta-analysis using individual participant data. SETTING: For the prioritisation, this included people affected by preterm birth and health-care practitioners in the UK relevant to preterm birth. The qualitative work on preterm birth and the development of the questionnaire involved parents of infants born at three maternity hospitals in southern England. The medical device was developed at Liverpool Women’s Hospital. The survey of practice involved UK neonatal units. The randomised trial was conducted at eight UK tertiary maternity hospitals. PARTICIPANTS: For prioritisation, 26 organisations and 386 individuals; for the interviews and questionnaire tool, 32 mothers and seven fathers who had a baby born before 32 weeks’ gestation for interviews evaluating the trolley, 30 people who had experienced it being used at the birth of their baby (19 mothers, 10 partners and 1 grandmother) and 20 clinicians who were present when it was being used; for the trial, 261 women expected to have a live birth before 32 weeks’ gestation, and their 276 babies. INTERVENTIONS: Providing neonatal care at very preterm birth beside the mother, and with the umbilical cord intact; timing of cord clamping at very preterm birth. MAIN OUTCOMES MEASURES: Research priorities for preterm birth; feasibility and acceptability of the trolley; feasibility of a randomised trial, death and intraventricular haemorrhage. REVIEW METHODS: Systematic review of Cochrane reviews (umbrella review); framework synthesis of ethics aspects of consent, with conceptual framework to inform selection criteria for empirical and analytical studies. The comparative review included studies using a questionnaire to assess satisfaction with care during childbirth, and provided psychometric information. RESULTS: Our prioritisation identified 104 research topics for preterm birth, with the top 30 ranked. An ethnographic analysis of decision-making during this process suggested ways that it might be improved. Qualitative interviews with parents about their experiences of very preterm birth identified two differences with term births: the importance of the staff appearing calm and of staff taking control. Following a comparative review, this led to the development of a questionnaire to assess parents’ views of care during very preterm birth. A systematic overview summarised evidence for delivery room neonatal care and revealed significant evidence gaps. The framework synthesis explored ethics issues in consent for trials involving sick or preterm infants, concluding that no existing process is ideal and identifying three important gaps. This led to the development of a two-stage consent pathway (oral assent followed by written consent), subsequently evaluated in our randomised trial. Our survey of practice for care at the time of birth showed variation in approaches to cord clamping, and that no hospitals were providing neonatal care with the cord intact. We showed that neonatal care could be provided beside the mother using either the mobile neonatal resuscitation trolley we developed or existing equipment. Qualitative interviews suggested that neonatal care beside the mother is valued by parents and acceptable to clinicians. Our pilot randomised trial compared cord clamping after 2 minutes and initial neonatal care, if needed, with the cord intact, with clamping within 20 seconds and initial neonatal care after clamping. This study demonstrated feasibility of a large UK randomised trial. Of 135 infants allocated to cord clamping ≥ 2 minutes, 7 (5.2%) died and, of 135 allocated to cord clamping ≤ 20 seconds, 15 (11.1%) died (risk difference –5.9%, 95% confidence interval –12.4% to 0.6%). Of live births, 43 out of 134 (32%) allocated to cord clamping ≥ 2 minutes had intraventricular haemorrhage compared with 47 out of 132 (36%) allocated to cord clamping ≤ 20 seconds (risk difference –3.5%, 95% CI –14.9% to 7.8%). LIMITATIONS: Small sample for the qualitative interviews about preterm birth, single-centre evaluation of neonatal care beside the mother, and a pilot trial. CONCLUSIONS: Our programme of research has improved understanding of parent experiences of very preterm birth, and informed clinical guidelines and the research agenda. Our two-stage consent pathway is recommended for intrapartum clinical research trials. Our pilot trial will contribute to the individual participant data meta-analysis, results of which will guide design of future trials. FUTURE WORK: Research in preterm birth should take account of the top priorities. Further evaluation of neonatal care beside the mother is merited, and future trial of alternative policies for management of cord clamping should take account of the meta-analysis. STUDY REGISTRATION: This study is registered as PROSPERO CRD42012003038 and CRD42013004405. In addition, Current Controlled Trials ISRCTN21456601. FUNDING: This project was funded by the National Institute for Health Research (NIHR) Programme Grants for Applied Research programme and will be published in full in Programme Grants for Applied Research; Vol. 7, No. 8. See the NIHR Journals Library website for further project information

    Why all the fuss about 2D semiconductors?

    Full text link
    Graphene is no longer alone; a family of atomically thin 2D semiconductors has emerged. Optoelectronics and photonics applications are in their experimental infancy but the future holds much promise.Comment: Commentary article, 1 figure, 1 tabl

    Mission impossible? Assessing the veracity of a mental health problem as result of a road traffic accident: a preliminary review of UK experts’ practices

    Get PDF
    The number of people claiming for personal injury after being involved in a road traffic accident (RTA) in the UK continues to soar. In April 2015, the UK Government intervened to implement measures aimed at reducing the prevalence of fraud within such personal injury claims. However, these reforms did not include claims for mental disorder that arise because of a RTA despite being responsible for substantially larger payouts in comparison with claims for whiplash. The present study examines the assessment practice for detecting fraudulent claims of this nature using a mixed methods survey analysing UK medico-legal professionals’ assessment methodologies (N = 37). The findings suggest comprehensively that assessment practices in this field are idiosyncratic. The findings evidence limitations in all aspects of the assessment process from medico-legal assessors being asked to undertake examinations without the presence of medical records to 44% of examiners being unaware of the three types of malingering. The article concludes with recommendations for improving both assessments and the assessment process for assessing RTA claimants in the UK

    Recognition and Alleviation of Pain in Animals

    Get PDF
    The pain and distress which animals experience as a consequence of their use by man figures prominently in discussions of animal welfare. Some improvements have been made in animal housing and husbandry practices and it is likely that further progress will be made in this field. In comparison, relatively little attention has been given to the problem of minimizing the pain and distress caused to animals by the various procedures to which they are subjected. The most publicized of these are the wide range of experimental techniques which are undertaken using laboratory animals, but also includes procedures such as castration of farm animals and neutering operations carried out on pet animals. The prevention or alleviation of the pain associated with such procedures is a complex problem with no single, simple solution. Consideration must be given to the use of analgesic drugs, the provision of high standards of general care, and the use of special nursing techniques. When dealing with post-operative care, the pre-operative management ofthe animal, the operative procedures and the anesthetic regime must all be evaluated and, when necessary, modified to minimize pain or discomfort

    First High-Convergence Cryogenic Implosion in a Near-Vacuum Hohlraum

    Get PDF
    Recent experiments on the National Ignition Facility [M. J. Edwards et al., Phys. Plasmas 20, 070501 (2013)] demonstrate that utilizing a near-vacuum hohlraum (low pressure gas-filled) is a viable option for high convergence cryogenic deuterium-tritium (DT) layered capsule implosions. This is made possible by using a dense ablator (high-density carbon), which shortens the drive duration needed to achieve high convergence: a measured 40% higher hohlraum efficiency than typical gas-filled hohlraums, which requires less laser energy going into the hohlraum, and an observed better symmetry control than anticipated by standard hydrodynamics simulations. The first series of near-vacuum hohlraum experiments culminated in a 6.8 ns, 1.2 MJ laser pulse driving a 2-shock, high adiabat (α ~ 3.5) cryogenic DT layered high density carbon capsule. This resulted in one of the best performances so far on the NIF relative to laser energy, with a measured primary neutron yield of 1.8×10[superscript 15] neutrons, with 20% calculated alpha heating at convergence ~27×
    • …
    corecore