23 research outputs found

    Parameterised contact model of pelvic bone and cartilage: development data set

    Get PDF
    The dataset was created as supplementary materials for the paper "Geometric parameterisation of pelvic bone and cartilage in contact analysis of the natural hip: an initial study". The dataset included the following documentation and data: the comparison results between segmentation-based model and parameterised model and the sensitivity analysis for the segmentation-based model; the detailed methodology of FE model development for segmentation-based model and parameterised model; the FE models for the two types of models and the solid models of the components for the two types of models

    The contact mechanics and occurrence of edge loading in modular metal-on-polyethylene total hip replacement during daily activities

    Get PDF
    The occurrence of edge loading in hip joint replacement has been associated with many factors such as prosthetic design, component malposition and activities of daily living. The present study aimed to quantify the occurrence of edge loading/contact at the articulating surface and to evaluate the effect of cup angles and edge loading on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip replacement (THR) during different daily activities. A three-dimensional finite element model was developed based on a modular MoP bearing system. Different cup inclination and anteversion angles were modelled and six daily activities were considered. The results showed that edge loading was predicted during normal walking, ascending and descending stairs activities under steep cup inclination conditions (≥55°) while no edge loading was observed during standing up, sitting down and knee bending activities. The duration of edge loading increased with increased cup inclination angles and was affected by the cup anteversion angles. Edge loading caused elevated contact pressure at the articulating surface and substantially increased equivalent plastic strain of the polyethylene liner. The present study suggested that correct positioning the component to avoid edge loading that may occur during daily activities is important for MoP THR in clinical practice

    Geometric parameterisation of pelvic bone and cartilage in contact analysis of the natural hip: an initial study

    Get PDF
    Parameterised finite element models of the human hip have the potential to allow controlled analysis of the effect of individual geometric features on the contact mechanics of the joint. However, the challenge lies in defining a set of parameters which sufficiently capture the joint geometry in order to distinguish between individuals. In this study, a simple set of parameters to describe the geometries of acetabulum and cartilage in the hip were extracted from two segmentation-based models, which were then used to generate the parameterised finite element models for the two subjects. The contact pressure and contact area at the articular surface predicted from the parameterised finite element models were compared with the results from the segmentation-based models. The differences in the predicted results between the parameterised models and segmentation-based models were found to be within 11% across seven activities simulated. In addition, the parameterised models were able to replicate features of the contact pressure/area fluctuations over the loading cycle that differed between the two subjects. These results provide confidence that the parameterised approach could be used to generate representative finite element models of the human hip for contact analysis. Such a method has the potential to be used to systematically evaluate geometric features that can be captured from simple clinical measurements and provide a cost- and time-effective approach for stratification of the acetabular geometries in the patient population

    The effect of cup outer sizes on the contact mechanics and cement fixation of cemented total hip replacements

    Get PDF
    One important loosening mechanism of the cemented total hip arthroplasty is the mechanical overload at the bone-cement interface and consequent failure of the cement fixation. Clinical studies have revealed that the outer diameter of the acetabular component is a key factor in influencing aseptic loosening of the hip arthroplasty. The aim of the present study was to investigate the influence of the cup outer diameter on the contact mechanics and cement fixation of a cemented total hip replacement (THR) with different wear penetration depths and under different cup inclination angles using finite element (FE) method. A three-dimensional FE model was developed based on a typical Charnley hip prosthesis. Two acetabular cup designs with outer diameters of 40 and 43 mm were modelled and the effect of cup outer diameter, penetration depth and cup inclination angle on the contact mechanics and cement fixation stresses in the cemented THR were studied. The results showed that for all penetration depths and cup inclination angles considered, the contact mechanics in terms of peak von Mises stress in the acetabular cup and peak contact pressure at the bearing surface for the two cup designs were similar (within 5%). However, the peak von Mises stress, the peak maximum principal stress and peak shear stress in the cement mantle at the bone-cement interface for the 43 mm diameter cup design were predicted to be lower compared to those for the 40 mm diameter cup design. The differences were predicted to be 15-19%, 15-22% and 18-20% respectively for different cup penetration depths and inclination angles, which compares to the clinical difference of aseptic loosening incidence of about 20% between the two cup designs

    Contact mechanics of modular metal-on-polyethylene total hip replacement under adverse edge loading conditions

    Get PDF
    Edge loading can negatively impact the biomechanics and long-term performance of hip replacements. Although edge loading has been widely investigated for hard-on-hard articulations, limited work has been conducted for hard-on-soft combinations. The aim of the present study was to investigate edge loading and its effect on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip replacement (THR). A three-dimensional finite element model was developed based on a modular MoP bearing. Different cup inclination angles and head lateral microseparation were modelled and their effect on the contact mechanics of the modular MoP hip replacement were examined. The results showed that lateral microseparation caused loading of the head on the rim of the cup, which produced substantial increases in the maximum von Mises stress in the polyethylene liner and the maximum contact pressure on both the articulating surface and backside surface of the liner. Plastic deformation of the liner was observed under both standard conditions and microseparation conditions, however, the maximum equivalent plastic strain in the liner under microseparation conditions of 2000 µm was predicted to be approximately six times that under standard conditions. The study has indicated that correct positioning the components to avoid edge loading is likely to be important clinically even for hard-on-soft bearings for THR

    Controlled Synthesis of Hollow α-Fe2O3 Microspheres Assembled With Ionic Liquid for Enhanced Visible-Light Photocatalytic Activity

    Get PDF
    Porous self-assembled α-Fe2O3 hollow microspheres were fabricated via an ionic liquid-assisted solvothermal reaction and sequential calcinations. The concentration of the ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate [C4Mim]BF4) was found to play a crucial role in the control of these α-Fe2O3 hollow structures. Trace amounts ionic liquid was used as the soft template to synthesize α-Fe2O3 hollow spheres with a large specific surface (up to 220 m2/g). Based on time-dependent experiments, the proposed formation mechanisms were presented. Under UV light irradiation, the as-synthesized α-Fe2O3 hollow spheres exhibited excellent photocatalysis in Rhodamine B (RhB) photodegradation and the rate constant was 2–3 times higher than α-Fe2O3 particles. The magnetic properties of α-Fe2O3 hollow structures were found to be closely associated with the shape anisotropy

    Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: a finite element study with biphasic acetabular cartilage properties

    Get PDF
    Hip hemiarthroplasty is a common treatment for femoral neck fracture. However, the acetabular cartilage may degenerate after hemiarthroplasty leading to postoperative failure and the need for revision surgery. The clearance between the acetabular cartilage and head of the prosthesis is one of the potential reasons for this failure. In this study, the influence of joint clearance on the biomechanical function of a generic hip model in hemiarthroplasty was investigated using biphasic numerical simulation. Both a prolonged loading period of 4000 s and dynamic gait load of 10 cycles were considered. It was found that a larger clearance led to a higher stress level, a faster reduction in load supported by the fluid and a faster cartilage consolidation process. Additionally, the mechanical performance of the acetabular cartilage in the natural model was similar to that in the hemiarthroplasty model with no clearance but different from the hemiarthroplasty models with clearances of 0.5mm and larger. The results demonstrated that a larger clearance in hip hemiarthroplasty is more harmful to the acetabular cartilage and prosthesis heads with more available dimensions (i.e. smaller increments in diameter) could be manufactured for surgeons to achieve a lower clearance, and reduced contact stress in hemiarthroplasty surgeries

    The influence of the representation of collagen fibre organisation on the cartilage contact mechanics of the hip joint

    Get PDF
    The aim of this study was to develop a finite element (FE) hip model with subject-specific geometry and biphasic cartilage properties. Different levels of detail in the representation of fibre reinforcement were considered to evaluate the feasibility to simplify the complex depth-dependent fibre pattern in the native hip joint. A FE model of a cadaveric hip with subject-specific geometry was constructed through micro-computed-tomography (µCT) imaging. The cartilage was assumed to be biphasic and fibre-reinforced with different levels of detail in the fibre representation. Simulations were performed for heel-strike, mid-stance and toe-off during walking and one-leg-stance over 1500s. It was found that the required level of detail in fibre representation depends on the parameter of interest. The contact stress of the native hip joint could be realistically predicted by simplifying the fibre representation to being orthogonally reinforced across the whole thickness. To predict the fluid pressure, depth-dependent fibre organisation is needed but specific split-line pattern on the surface of cartilage is not necessary. Both depth-dependent and specific surface fibre orientations are required to simulate the strains

    Contact mechanics of metal on polyethylene hip replacements

    Get PDF
    Metal-on-ultra high molecular weight polyethylene (UHMWPE) total hip replacement (THR) has been the most popular and clinically successful hip prosthesis to date. The long-term performance of THR depends on both the tribological characteristics and biomechanical behaviour of the prosthesis. This project focused on understanding the contact mechanics and mechanical behaviour of cemented and cementless metal-on-UHMWPE THRs under different conditions using a computational approach. Three-dimensional (3D) computational models of THRs with realistic pelvic bone were developed. Two typical bearings, the Charnley hip and the Pinnacle cup system, were investigated. The effect of different factors on the contact mechanics and cement stresses for Charnley THR were examined. Additionally, the contact mechanics and mechanical behaviour of Pinnacle THR under daily activities, standard and microseparation conditions were analysed. The cup angles and penetration depths in the cup, and the sizes of the components were found to have a significant effect on the contact mechanics and cement stresses for Charnley THR. The stresses at the bone-cement interface for the Charnley THR with outer diameter of 40 mm were predicted to be higher than that of 43 mm, the difference was found to be consistent with the clinical observation of different aseptic loosening rates. The cup angles and radial clearances were found to have a synergistic effect on the contact mechanics of Pinnacle THR. Edge loading on both articulating surface and backside surface of the liner was observed during some daily activities due to steep cup inclination angles and smaller radial clearance. The introduction of microseparation into the gait cycle, especially when combined with steep cup inclination angles, resulted in concentrated stresses and plastic deformation in the liner, which would cause potential damage to the liner. Therefore, it is critically important to reduce the levels of rotational and translational mal-positioning of the components clinically
    corecore