2,050 research outputs found
Diagnositic value of pelvic enthesitis on MRI of the sacroiliac joints in enthesitis related arthritis
Background: To determine the prevalence and diagnostic value of pelvic enthesitis on MRI of the sacroiliac (SI) joints in enthesitis related arthritis (ERA).
Methods: We retrospectively studied 143 patients aged 6-18 years old who underwent MRI of the SI joints for clinically suspected sacroiliitis between 2006-2014. Patients were diagnosed with ERA according to the International League of Associations for Rheumatology (ILAR) criteria. All MRI studies were reassessed for the presence of pelvic enthesitis, which was correlated to the presence of sacroiliitis on MRI and to the final clinical diagnosis. The added value for detection of pelvic enthesitis and fulfilment of criteria for the diagnosis of ERA was studied.
Results: Pelvic enthesitis was seen in 23 of 143 (16 %) patients. The most commonly affected sites were the entheses around the hip (35 % of affected entheses) and the retroarticular interosseous ligaments (32 % of affected entheses). MRI showed pelvic enthesitis in 21 % of patients with ERA and in 13 % of patients without ERA. Pelvic enthesitis was seen on MRI in 7/51 (14 %) patients with clinically evident enthesitis, and 16/92 (17 %) patients without clinically evident enthesitis. In 7 of 11 ERA-negative patients without clinical enthesitis but with pelvic enthesitis on MRI, the ILAR criteria could have been fulfilled, if pelvic enthesitis on MRI was included in the criteria.
There is a high correlation between pelvic enthesitis and sacroiliitis, with sacroiliitis present in 17/23 (74 %) patients with pelvic enthesitis.
Conclusions: Pelvic enthesitis may be present in children with or without clinically evident peripheral enthesitis. There is a high correlation between pelvic enthesitis and sacroiliitis on MRI of the sacroiliac joints in children. As pelvic enthesitis indicates active inflammation, it may play a role in assessment of the inflammatory status. Therefore, it should be carefully sought and noted by radiologists examining MRI of the sacroiliac joints in children
A theoretical investigation of ferromagnetic tunnel junctions with 4-valued conductances
In considering a novel function in ferromagnetic tunnel junctions consisting
of ferromagnet(FM)/barrier/FM junctions, we theoretically investigate multiple
valued (or multi-level) cell property, which is in principle realized by
sensing conductances of four states recorded with magnetization configurations
of two FMs; that is, (up,up), (up,down), (down,up), (down,down). To obtain such
4-valued conductances, we propose FM1/spin-polarized barrier/FM2 junctions,
where the FM1 and FM2 are different ferromagnets, and the barrier has spin
dependence. The proposed idea is applied to the case of the barrier having
localized spins. Assuming that all the localized spins are pinned parallel to
magnetization axes of the FM1 and FM2, 4-valued conductances are explicitly
obtained for the case of many localized spins. Furthermore, objectives for an
ideal spin-polarized barrier are discussed.Comment: 9 pages, 3 figures, accepted for publication in J. Phys.: Condens.
Matte
Deposition of 13C tracer and impurity elements on the divertor of Wendelstein 7-X
Carbon impurity transport and deposition were investigated in the Wendelstein 7-X stellarator by injecting isotopically labelled methane ((CH4)-C-13) into the edge plasma during the last plasma operations of its Operational Phase (OP) 1.2B experimental campaign. C-13 deposition was measured by secondary ion mass spectrometry (SIMS) on three upper divertor tiles located on the opposite side of the vessel to the(13)CH(4) inlet. The highest C-13 inventories were found as stripe-like patterns on both sides of the different strike lines. These high deposition areas were also analysed for their impurity contents and the depth profiles of the main elements in the layers. Layered deposition of different impurity elements such as Cr, Ni, Mo and B was found to reflect various events such as high metallic impurities during the OP1.2A and three boronizations carried out during OP1.2B.Peer reviewe
Ballistic spin-polarized transport and Rashba spin precession in semiconductor nanowires
We present numerical calculations of the ballistic spin-transport properties
of quasi-one-dimensional wires in the presence of the spin-orbit (Rashba)
interaction. A tight-binding analog of the Rashba Hamiltonian which models the
Rashba effect is used. By varying the robustness of the Rashba coupling and the
width of the wire, weak and strong coupling regimes are identified. Perfect
electron spin-modulation is found for the former regime, regardless of the
incident Fermi energy and mode number. In the latter however, the
spin-conductance has a strong energy dependence due to a nontrivial subband
intermixing induced by the strong Rashba coupling. This would imply a strong
suppression of the spin-modulation at higher temperatures and source-drain
voltages. The results may be of relevance for the implementation of
quasi-one-dimensional spin transistor devices.Comment: 19 pages (incl. 9 figures). To be published in PR
Basic obstacle for electrical spin-injection from a ferromagnetic metal into a diffusive semiconductor
We have calculated the spin-polarization effects of a current in a two
dimensional electron gas which is contacted by two ferromagnetic metals. In the
purely diffusive regime, the current may indeed be spin-polarized. However, for
a typical device geometry the degree of spin-polarization of the current is
limited to less than 0.1%, only. The change in device resistance for parallel
and antiparallel magnetization of the contacts is up to quadratically smaller,
and will thus be difficult to detect.Comment: Revtex, 4 pages, 3 figures (eps), Definition of spin pilarization
changed to standard definition in GMR, some straight forward algebra removed.
To appear as PRB Rap. Comm. August 15t
Protecting Quantum Information with Entanglement and Noisy Optical Modes
We incorporate active and passive quantum error-correcting techniques to
protect a set of optical information modes of a continuous-variable quantum
information system. Our method uses ancilla modes, entangled modes, and gauge
modes (modes in a mixed state) to help correct errors on a set of information
modes. A linear-optical encoding circuit consisting of offline squeezers,
passive optical devices, feedforward control, conditional modulation, and
homodyne measurements performs the encoding. The result is that we extend the
entanglement-assisted operator stabilizer formalism for discrete variables to
continuous-variable quantum information processing.Comment: 7 pages, 1 figur
Long-term efficiency of infliximab in patients with ankylosing spondylitis : real life data confirm the potential for dose reduction
Objective: To analyse the treatment outcome of patients with ankylosing spondylitis (AS) in the European AS infliximab cohort (EASIC) study after a total period of 8 years with specific focus on dosage and the duration of intervals between infliximab infusions.
Methods: EASIC included patients with AS who had received infliximab for 2 years as part of the ASSERT trial. After that period, rheumatologists were free to change the dose or the intervals of infliximab. Clinical data were status at baseline, end of ASSERT and for a total of 8 years of follow-up.
Results: Of the initially 71 patients with AS from EASIC, 55 patients (77.5%) had completed the 8th year of anti-tumour necrosis factor (TNF) treatment. Of those, 48 patients (87.3%) still continued on infliximab. The mean infusion interval increased slightly from 6 to 7.1 +/- 1.5 weeks, while 45.8% patients had increased the intervals up to a maximum of 12 weeks. The mean infliximab dose remained stable over time, with a minimum of 3.1 mg/kg and a maximum of 6.4 mg/kg. In patients receiving <5 mg/kg infliximab, the mean infusion interval increased to 7.0 +/- 1.2 weeks. In total, the mean cumulative dose per patient and per year decreased from 3566.30 to 2973.60 mg.
Conclusions: We could observe that over a follow-up of 8 years of treatment with infliximab, >85% patients still remained on the same treatment, without any major safety events. Furthermore, both the infusion intervals and also the mean infliximab dose were modestly reduced in >= 70% of the patients without the loss of clinical efficiency
Entanglement concentration of continuous variable quantum states
We propose two probabilistic entanglement concentration schemes for a single
copy of two-mode squeezed vacuum state. The first scheme is based on the
off-resonant interaction of a Rydberg atom with the cavity field while the
second setup involves the cross Kerr interaction, auxiliary mode prepared in a
strong coherent state and a homodyne detection. We show that the
continuous-variable entanglement concentration allows us to improve the
fidelity of teleportation of coherent states.Comment: 7 pages, 7 figure
Recommended from our members
Measurements of the transverse-momentum-dependent cross sections of J /ψ production at mid-rapidity in proton+proton collisions at s =510 and 500 GeV with the STAR detector
We present measurements of the differential cross sections of inclusive J/ψ meson production as a function of transverse momentum (pTJ/ψ) using the μ+μ- and e+e- decay channels in proton+proton collisions at center-of-mass energies of 510 and 500 GeV, respectively, recorded by the STAR detector at the Relativistic Heavy Ion Collider. The measurement from the μ+μ- channel is for
Recommended from our members
Bulk properties of the system formed in Au+Au collisions at sNN =14.5 GeV at the BNL STAR detector
We report systematic measurements of bulk properties of the system created in Au+Au collisions at sNN=14.5 GeV recorded by the STAR detector at the Relativistic Heavy Ion Collider (RHIC). The transverse momentum spectra of π±, K±, and p(p) are studied at midrapidity (|y|<0.1) for nine centrality intervals. The centrality, transverse momentum (pT), and pseudorapidity (η) dependence of inclusive charged particle elliptic flow (v2), and rapidity-odd charged particles directed flow (v1) results near midrapidity are also presented. These measurements are compared with the published results from Au+Au collisions at other energies, and from Pb+Pb collisions at sNN=2.76 TeV. The results at sNN=14.5 GeV show similar behavior as established at other energies and fit well in the energy dependence trend. These results are important as the 14.5-GeV energy fills the gap in μB, which is of the order of 100 MeV, between sNN=11.5 and 19.6 GeV. Comparisons of the data with UrQMD and AMPT models show poor agreement in general
- …