227 research outputs found

    A Radon Progeny Deposition Model

    Full text link
    The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly Rn-222) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of Pb-210 on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.Comment: Proceedings of the Topical Workshop in Low Radioactivity Techniques, (Sudbury, Canada) August 28-29, 201

    Evaluating a palliative care education programme for domiciliary care workers

    Get PDF
    Background: Many domiciliary care workers have reported low confidence and isolation when delivering end of life care in patients’ homes. Project Extension for Community Healthcare Outcomes (ECHO) is an initiative that has demonstrated success in increasing confidence and knowledge of end of life care in UK nursing home and community hospice workers, but it has not been evaluated with domiciliary care workers. Aim: To test the acceptability of Project ECHO to domiciliary care workers as a means of increasing their knowledge of, and confidence in, delivering palliative care, and its effectiveness in reducing their isolation by developing a community of practice. Method: A service evaluation, involving one domiciliary care agency delivering care in the community, was conducted from May 2018 to April 2019. The participants were 25 home care workers who were employed by the agency. Participants were invited to attend an event at which gaps in their knowledge were identified, and a curriculum of learning on the Project ECHO programme was developed. The learning involved 12 educational sessions over 12 months, with each session teaching a different component of palliative care. Questionnaires were completed by the participants before and after the educational sessions to assess their effect. In addition, a focus group was conducted with four of the participants. Results: Comparison of the questionnaires completed before and after participating in the education sessions revealed an increase in self-reported knowledge across all 12 topics of the curriculum and an increase in confidence in seven of the 12 topics. However, attendance across the 12 sessions was variable, with no more than nine being attended by any one participant. Conclusion: Palliative care education for domiciliary care staff using ECHO methodology was well received, relevant and accessible, and may have the potential to improve self-assessed knowledge and confidence. However, finding an ideal time for as many staff to attend as possible may be challenging

    Quenching Measurements and Modeling of a Boron-Loaded Organic Liquid Scintillator

    Get PDF
    Organic liquid scintillators are used in a wide variety of applications in experimental nuclear and particle physics. Boron-loaded scintillators are particularly useful for detecting neutron captures, due to the high thermal neutron capture cross section of 10B. These scintillators are commonly used in neutron detectors, including the DarkSide-50 neutron veto, where the neutron may produce a signal when it scatters off protons in the scintillator or when it captures on 10B. Reconstructing the energy of these recoils is complicated by scintillation quenching. Understanding how nuclear recoils are quenched in these scintillators is an important and difficult problem. In this article, we present a set of measurements of neutron-induced proton recoils in a boron-loaded organic liquid scintillator at recoil energies ranging from 57–467 keV, and we compare these measurements to predictions from different quenching models. We find that a modified Birks’ model whose denominator is quadratic in dE/dx best describes the measurements, with χ 2 /NDF= 1.6. This result will help model nuclear recoil scintillation in similar detectors and can be used to improve their neutron tagging efficiency

    ‘Palliative care education in nursing homes: a qualitative evaluation of telementoring

    Get PDF
    There is an increasing need to support nursing homes in palliative care to reduce suffering and avoid unnecessary hospital admissions at the end of life. Providing education to nursing homes faces many barriers including structural systems and cultural issues. In order to overcome some of these barriers, education using Project Extension for Community Health Outcomes (ECHO) methodology has been delivered to nursing homes throughout a large city in England. This paper aims to explore participant experience in Project ECHO for nursing homes. Methodology Qualitative semistructured interviews with a purposive sample of nursing home staff. Interviews were conducted by one researcher and transcribed verbatim. Line-by-line coding and categorisation were used to form themes. Results Eleven interviews were completed with data saturation reached by interview eight. The following themes were revealed: Barriers and facilitators to accessing Project ECHO, Community of Practice and Communication with nursing homes and data extraction. Conclusion Project ECHO is an accessible, acceptable and engaging way of delivering palliative care education to nursing homes combatting some of the traditional barriers that nursing homes face in accessing training

    In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

    Get PDF
    The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres

    Recommended conventions for reporting results from direct dark matter searches

    Get PDF
    The field of dark matter detection is a highly visible and highly competitive one. In this paper, we propose recommendations for presenting dark matter direct detection results particularly suited for weak-scale dark matter searches, although we believe the spirit of the recommendations can apply more broadly to searches for other dark matter candidates, such as very light dark matter or axions. To translate experimental data into a final published result, direct detection collaborations must make a series of choices in their analysis, ranging from how to model astrophysical parameters to how to make statistical inferences based on observed data. While many collaborations follow a standard set of recommendations in some areas, for example the expected flux of dark matter particles (to a large degree based on a paper from Lewin and Smith in 1995), in other areas, particularly in statistical inference, they have taken different approaches, often from result to result by the same collaboration. We set out a number of recommendations on how to apply the now commonly used Profile Likelihood Ratio method to direct detection data. In addition, updated recommendations for the Standard Halo Model astrophysical parameters and relevant neutrino fluxes are provided. The authors of this note include members of the DAMIC, DarkSide, DARWIN, DEAP, LZ, NEWS-G, PandaX, PICO, SBC, SENSEI, SuperCDMS, and XENON collaborations, and these collaborations provided input to the recommendations laid out here. Wide-spread adoption of these recommendations will make it easier to compare and combine future dark matter results

    Results from the first use of low radioactivity argon in a dark matter search

    Get PDF
    Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).Comment: Accepted by Phys. Rev.

    Impact of pericardial adhesions on diastolic function as assessed by vortex formation time, a parameter of transmitral flow efficiency

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Pericardial adhesions are a pathophysiological marker of constrictive pericarditis (CP), which impairs cardiac filling by limiting the total cardiac volume compliance and diastolic filling function. We studied diastolic transmitral flow efficiency as a new parameter of filling function in a pericardial adhesion animal model. We hypothesized that vortex formation time (VFT), an index of optimal efficient diastolic transmitral flow, is altered by patchy pericardial-epicardial adhesions.</p> <p>Methods</p> <p>In 8 open-chest pigs, the heart was exposed while preserving the pericardium. We experimentally simulated early pericardial constriction and patchy adhesions by instilling instant glue into the pericardial space and using pericardial-epicardial stitches. We studied left ventricular (LV) function and characterized intraventricular blood flow with conventional and Doppler echocardiography at baseline and following the experimental intervention.</p> <p>Results</p> <p>Significant decreases in end-diastolic volume, ejection fraction, stroke volume, and late diastolic filling velocity reflected the effects of the pericardial adhesions. The mean VFT value decreased from 3.61 ± 0.47 to 2.26 ± 0.45 (P = 0.0002). Hemodynamic variables indicated the inhibiting effect of pericardial adhesion on both contraction (decrease in systolic blood pressure and +dP/dt decreased) and relaxation (decrease in the magnitude of -dP/dt and prolongation of Tau) function.</p> <p>Conclusion</p> <p>Patchy pericardial adhesions not only negatively impact LV mechanical functioning but the decrease of VFT from normal to suboptimal value suggests impairment of transmitral flow efficiency.</p

    The Darkside-50 Outer Detectors

    Get PDF
    DarkSide-50 is a dark matter detection experiment searching for Weakly Interacting Massive Particles (WIMPs), in Gran Sasso National Laboratory. For experiments like DarkSide-50, neutrons are one of the primary backgrounds that can mimic WIMP signals. The experiment consists of three nested detectors: a liquid argon time projection chamber surrounded by two outer detectors. The outermost detector is a 10 m by 11 m cylindrical water Cherenkov detector with 80 PMTs, designed to provide shielding and muon vetoing. Inside the water Cherenkov detector is the 4 m diameter spherical boron-loaded liquid scintillator veto, with a cocktail of pseudocumene, trimethyl borate, and PPO wavelength shifter, designed to provide shielding, neutron vetoing, and in situ measurements of the TPC backgrounds. We present design and performance details of the DarkSide-50 outer detectors.71814th International Conference on Topics in Astroparticle and Underground Physics (TAUP)Sep 07-11, 2015Torino, ITAL
    • 

    corecore