281 research outputs found

    Defining the gap between research and practice in public relations programme evaluation - towards a new research agenda

    Get PDF
    The current situation in public relations programme evaluation is neatly summarized by McCoy who commented that 'probably the most common buzzwords in public relations in the last ten years have been evaluation and accountability' (McCoy 2005, 3). This paper examines the academic and practitioner-based literature and research on programme evaluation and it detects different priorities and approaches that may partly explain why the debate on acceptable and agreed evaluation methods continues. It analyses those differences and proposes a research agenda to bridge the gap and move the debate forward

    Long-Term Clinical Outcomes With Sirolimus-Eluting Coronary Stents Five-Year Results of the RAVEL Trial

    Get PDF
    ObjectivesThis study examined the clinical outcomes at 5 years in RAVEL (A Randomized Comparison of a Sirolimus-Eluting Stent With a Standard Stent for Coronary Revascularization), the first controlled trial of drug-eluting stents.BackgroundThe 6-month rate of angiographic coronary restenosis has been markedly lowered by sirolimus-eluting stents (SES). The long-term performance of drug-eluting stents, however, is under close scrutiny.MethodsThe trial included 238 patients (mean age 60.7 Ā± 10.4 years, 76% men) with a single, de novo native coronary artery lesion, randomly assigned to treatment with SES versus bare-metal stents (BMS). Rates of major adverse cardiac events (MACE), defined as all-cause mortality, myocardial infarction, and percutaneous or surgical revascularization up to 5 years of follow-up, and rates of stent thrombosis were compared between the 2 treatment groups.ResultsComplete datasets were available in 92.5% of patients treated with SES and 89.1% of patients assigned to BMS. The 1-, 3-, and 5-year rates of survival free from target lesion revascularization (TLR) were, respectively, 99.2%, 93.8%, and 89.7% in the SES group versus 75.9%, 75.0%, and 74.0% in the control group (p < 0.001; log-rank). Rates of all MACE at 5 years were 25.8% in patients treated with SES versus 35.2% in patients assigned to BMS (p = 0.03; log-rank). Rates of stent thrombosis, per protocol or by the Academic Research Consortium definitions, were similar in both groups.ConclusionsThe 5-year rate of TLR associated with SES was significantly lower than that with BMS. There was no apparent adverse effect associated with the use of SES, although the trial was not powered to examine uncommon complications

    Randomized Comparison of Everolimus- and Paclitaxel-Eluting Stents 2-Year Follow-Up From the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) IV Trial

    Get PDF
    ObjectivesWe sought to determine whether the differences in outcomes present between everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES) in the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) IV trial at 1 year were sustained with longer-term follow-up.BackgroundIn the SPIRIT IV trial, patients undergoing percutaneous coronary intervention who were randomized to EES compared with PES experienced lower 1-year rates of target lesion failure (cardiac death, target vessel myocardial infarction [MI], or ischemia-driven target lesion revascularization [TLR]), with significant reductions in the individual rates of MI, TLR, and stent thrombosis.MethodsWe prospectively randomized 3,687 patients with up to 3 noncomplex previously untreated native coronary artery lesions to EES versus PES at 66 U.S. sites. Follow-up through 2 years is complete in 3,578 patents (97.0%).ResultsTreatment with EES compared with PES reduced the 2-year rates of TLF (6.9% vs. 9.9%, p = 0.003), all MI (2.5% vs. 3.9%, p = 0.02), Q-wave MI (0.1% vs. 0.8%, p = 0.002), stent thrombosis (0.4% vs. 1.2%, p = 0.008), and ischemia-driven TLR (4.5% vs. 6.9%, p = 0.004), with nonsignificantly different rates of all-cause and cardiac mortality. Between 1 year and 2 years, there were no significant differences in adverse event rates between the 2 stent types.ConclusionsIn the large-scale, prospective, multicenter, randomized SPIRIT IV trial, the benefits of EES compared with those of PES present at 1 year were sustained at 2 years. (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System; NCT01016041

    A Randomized Comparison of the Endeavor Zotarolimus-Eluting Stent Versus the TAXUS Paclitaxel-Eluting Stent in De Novo Native Coronary Lesions 12-Month Outcomes From the ENDEAVOR IV Trial

    Get PDF
    ObjectivesThe ENDEAVOR IV (Randomized Comparison of Zotarolimus-Eluting and Paclitaxel-Eluting Stents in Patients with Coronary Artery Disease) trial evaluated the safety and efficacy of the zotarolimus-eluting stent (ZES) compared with the paclitaxel-eluting stent (PES).BackgroundFirst-generation drug-eluting stents have reduced angiographic and clinical restenosis, but long-term safety remains controversial. A second-generation drug-eluting stent, which delivers zotarolimus, a potent antiproliferative agent, via a biocompatible phosphorylcholine polymer on a cobalt alloy thin-strut stent has shown promising experimental and early clinical results.MethodsThis is a prospective, randomized (1:1), single-blind, controlled trial comparing outcomes of patients with single de novo coronary lesions treated with ZES or PES. The primary end point was noninferiority of 9-month target vessel failure defined as cardiac death, myocardial infarction, or target vessel revascularization.ResultsAmong a total of 1,548 patients assigned to ZES (n = 773) or PES (n = 775), at 9 months, ZES was noninferior to PES with rates of target vessel failure 6.6% versus 7.1%, respectively (pnoninferiorityā‰¤ 0.001). There were fewer periprocedural myocardial infarctions with ZES (0.5% vs. 2.2%; p = 0.007), whereas at 12 months, there were no significant differences between groups in rates of cardiac death, myocardial infarction, target vessel revascularization, or stent thrombosis. Although incidence of 8-month binary angiographic in-segment restenosis was higher in patients treated with ZES versus PES (15.3% vs. 10.4%; p = 0.284), rates of 12-month target lesion revascularization were similar (4.5% vs. 3.2%; p = 0.228), especially in patients without planned angiographic follow-up (3.6% vs. 3.2%; p = 0.756).ConclusionsThese findings demonstrate that ZES has similar clinical safety and efficacy compared with PES in simple and medium complexity single de novo coronary lesions. (ENDEAVOR IV Clinical Trial; NCT00217269

    A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Paclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation paclitaxel-eluting stent which incorporates a novel, thinner-strut, platinum-enriched metal alloy platform. The stent is intended to have enhanced radiopacity and improved deliverability compared to other paclitaxel-eluting stents. The safety and efficacy of the TAXUS Element stent are being evaluated in the pivotal PERSEUS clinical trials.</p> <p>Methods/Design</p> <p>The PERSEUS trials include two parallel studies of the TAXUS Element stent in single, de novo coronary atherosclerotic lesions. The PERSEUS Workhorse study is a prospective, randomized (3:1), single-blind, non-inferiority trial in subjects with lesion length ā‰¤28 mm and vessel diameter ā‰„2.75 mm to ā‰¤4.0 mm which compares TAXUS Element to the TAXUS Express<sup>2 </sup>paclitaxel-eluting stent system. The Workhorse study employs a novel Bayesian statistical approach that uses prior information to limit the number of study subjects exposed to the investigational device and thus provide a safer and more efficient analysis of the TAXUS Element stent. PERSEUS Small Vessel is a prospective, single-arm, superiority trial in subjects with lesion length ā‰¤20 mm and vessel diameter ā‰„2.25 mm to <2.75 mm that compares TAXUS Element with a matched historical bare metal Express stent control.</p> <p>Discussion</p> <p>The TAXUS PERSEUS clinical trial program uses a novel statistical approach to evaluate whether design and metal alloy iterations in the TAXUS Element stent platform provide comparable safety and improved procedural performance compared to the previous generation Express stent. PERSEUS trial enrollment is complete and primary endpoint data are expected in 2010. PERSEUS Workhorse and Small Vessel are registered at <url>http://www.clinicaltrials.gov</url>, identification numbers NCT00484315 and NCT00489541.</p

    Atrial Fibrillation Burden and Atrial Shunt Therapy in Heart Failure With Preserved Ejection Fraction

    Get PDF
    Background: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF). Objectives: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden. Methods: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days). The investigators determined the association of baseline AF burden with long-term clinical events and examined the effect of atrial shunt therapy on AF burden over time. Results: Among 367 patients with cardiac monitoring data at baseline and follow-up, 194 (53%) had a history of AF or atrial flutter (AFL), and median baseline AF burden was 0.012% (IQR: 0%-1.3%). After multivariable adjustment, baseline AF burden ā‰„0.012% was significantly associated with heart failure (HF) events (HR: 2.00; 95% CI: 1.17-3.44; P = 0.01) both with and without a history of AF or AFL (P for interaction = 0.68). Adjustment for left atrial reservoir strain attenuated the baseline AF burden-HF event association (HR: 1.71; 95% CI: 0.93-3.14; P = 0.08). Of the 367 patients, 141 (38%) had patch-detected AF during follow-up without a history of AF or AFL. Atrial shunt therapy did not change AF incidence or burden during follow-up. Conclusions: In HFpEF and HFmrEF, nearly 40% of patients have subclinical AF by 1 year. Baseline AF burden, even at low levels, is associated with HF events. Atrial shunt therapy does not affect AF incidence or burden.</p

    Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortiumā€ 

    Get PDF
    To propose standardized consensus definitions for important clinical endpoints in transcatheter aortic valve implantation (TAVI), investigations in an effort to improve the quality of clinical research and to enable meaningful comparisons between clinical trials. To make these consensus definitions accessible to all stakeholders in TAVI clinical research through a peer reviewed publication, on behalf of the public health
    • ā€¦
    corecore