437 research outputs found

    Optimizing Two-Color Semiconductor Nanocrystal Immunoassays in Single Well Microtiter Plate Formats

    Get PDF
    The simultaneous detection of two analytes, chicken IgY (IgG) and Staphylococcal enterotoxin B (SEB), in the single well of a 96-well plate is demonstrated using luminescent semiconductor quantum dot nanocrystal (NC) tracers. The NC-labeled antibodies were prepared via sulfhydryl-reactive chemistry using a facile protocol that took <3 h. Dose response curves for each target were evaluated in a single immunoassay format and compared to Cy5, a fluorophore commonly used in fluorescent immunoassays, and found to be equivalent. Immunoassays were then performed in a duplex format, demonstrating multiplex detection in a single well with limits of detection equivalent to the single assay format: 9.8 ng/mL chicken IgG and 7.8 ng/mL SEB

    Participatory Situational Analysis: How can policy and regulation support resource recovery? Synthesis workshop report

    Get PDF
    The results presented in this report arise from four workshops that took place throughout the UK in Northern Ireland, Scotland, Wales and England. Using a ‘participatory situational analysis approach each workshop strived to answer the question: “If we wanted to realise resource recovery in the UK, how would it be possible within our policy and regulatory context?” Stakeholders attending the workshops ranged from academia, government, industry and the NGO WRAP. This report captures their insights into the diverse legislative areas that need to be integrated and aligned when aiming for a more circular economy, the ways in which policy and regulation enable this, and which particular actors need to be involved and the actions they should take. Taking the results into account, an action plan with seven key elements was recommended. This report is the outcome of the RRfW mini-project ‘Participatory situational analysis for the implementation of RRfW technologies and vision‘

    Sitting posture affects pelvic floor muscle activity in parous women: An observational study

    Get PDF
    Question Do different sitting postures require different levels of pelvic floor and abdominal muscle activity in healthy women? Design Observational study. Participants Eight parous women with no pelvic floor dysfunction. Outcome measures Bilateral activity of pelvic floor muscles (assessed vaginally) and two abdominal muscles, obliquus internus abdominis and obliquus externus abdominis, during three sitting postures. Results There was a significant increase in pelvic floor muscle activity from slump supported sitting (mean 7.2% maximal voluntary contraction, SD 4.8) to both upright unsupported sifting (mean 12.6% maximal voluntary contraction, SD 7.8) (p = 0.01) and very tall unsupported sitting (mean 24.3% maximal voluntary contraction, SD 14.2) (p = 0.004). Activity in both abdominal muscles also increased but did not reach statistical significance. Conclusion Both unsupported sitting postures require greater pelvic floor muscle activity than the supported sitting posture

    Atmospheric carbon capture performance of legacy iron and steel waste

    Get PDF
    Legacy iron (Fe) and steel wastes have been identified as a significant source of silicate minerals, which can undergo carbonation reactions and thus sequester carbon dioxide (CO2). In reactor experiments, i.e., at elevated temperatures, pressures, or CO2 concentrations, these wastes have high silicate to carbonate conversion rates. However, what is less understood is whether a more “passive” approach to carbonation can work, i.e., whether a traditional slag emplacement method (heaped and then buried) promotes or hinders CO2 sequestration. In this paper, the results of characterization of material retrieved from a first of its kind drilling program on a historical blast furnace slag heap at Consett, U.K., are reported. The mineralogy of the slag material was near uniform, consisting mainly of melilite group minerals with only minor amounts of carbonate minerals detected. Further analysis established that total carbon levels were on average only 0.4% while average calcium (Ca) levels exceeded 30%. It was calculated that only ∌3% of the CO2 sequestration potential of the >30 Mt slag heap has been utilized. It is suggested that limited water and gas interaction and the mineralogy and particle size of the slag are the main factors that have hindered carbonation reactions in the slag heap

    International trials of vertical flow reactors for coal mine water treatment

    Get PDF
    Vertical flow reactors (VFRs) were tested at coal mine sites in New Zealand, South Korea, and the USA. The objective was to evaluate the iron removal efficiency and iron removal mechanisms during field trials at low pH and circumneutral pH, and to evaluate the potential use of VFRs as stand-alone systems or in combination with other passive treatment technologies. Total iron and manganese removal efficiencies at circumneutral pH (6–8) often exceeded 90%, with effluent concentrations less than 1 mg/L. This is attributed to both homogeneous and heterogenous Fe(II) oxidation and filtration of the precipitated ferrihydrite. Iron removal efficiencies at moderately acidic conditions (pH 3–4.5) averaged close to 40%, with an average 71.0% removal in one of the trials after iron removal capacity was stabilized. Microbial Fe(II) oxidation and precipitation as schwertmannite together with aggregation of colloidal and nano-particulate Fe(III) are suspected to be the main removal mechanisms. Iron solubility limited removal under very acidic conditions (pH < 3). The reproducibility of the results with respect to previous research confirmed that VFRs can be used as stand-alone passive treatment systems for iron removal from mine waters with a footprint less than half of the area required by a conventional aerobic wetland. A VFR can also provide useful iron pretreatment for other passive treatment systems under circumneutral conditions, but would have to be combined with alkaline generating systems to achieve full iron removal from acidic mine waters

    Male Imprisoned Firesetters Have Different Characteristics than Other Imprisoned Offenders and Require Specialist Treatment

    Get PDF
    Objective: This study investigated whether a group of firesetters (n = 68) could be distinguished, psychologically, from a matched group of non-firesetting offenders (n = 68). Method: Participants completed measures examining psychological variables relating to fire, emotional/ self-regulation, social competency, self-concept, boredom proneness, and impression management. Official prison records were also examined to record offending history and other offense-related variables. A series of MANOVAs were conducted with conceptually related measures identified as the dependent variables. Follow up discriminant function and clinical cut-off score analyses were also conducted to examine the best discriminating variables for firesetters. Results: Firesetters were clearly distinguishable, statistically, from non-firesetters on three groups of conceptually related measures relating to: fire, emotional/self-regulation, and self-concept. The most successful variables for the discrimination of firesetters determined via statistical and clinical significance testing were higher levels of anger-related cognition, interest in serious fires, and identification with fire and lower levels of perceived fire safety awareness, general self-esteem, and external locus of control. Conclusions: Firesetters appear to be a specialist group of offenders who hold unique psychological characteristics. Firesetters are likely to require specialist treatment to target these psychological needs as opposed to generic offending behavior programs

    Terbium to Quantum Dot FRET Bioconjugates for Clinical Diagnostics: Influence of Human Plasma on Optical and Assembly Properties

    Get PDF
    Förster resonance energy transfer (FRET) from luminescent terbium complexes (LTC) as donors to semiconductor quantum dots (QDs) as acceptors allows extraordinary large FRET efficiencies due to the long Förster distances afforded. Moreover, time-gated detection permits an efficient suppression of autofluorescent background leading to sub-picomolar detection limits even within multiplexed detection formats. These characteristics make FRET-systems with LTC and QDs excellent candidates for clinical diagnostics. So far, such proofs of principle for highly sensitive multiplexed biosensing have only been performed under optimized buffer conditions and interactions between real-life clinical media such as human serum or plasma and LTC-QD-FRET-systems have not yet been taken into account. Here we present an extensive spectroscopic analysis of absorption, excitation and emission spectra along with the luminescence decay times of both the single components as well as the assembled FRET-systems in TRIS-buffer, TRIS-buffer with 2% bovine serum albumin, and fresh human plasma. Moreover, we evaluated homogeneous LTC-QD FRET assays in QD conjugates assembled with either the well-known, specific biotin-streptavidin biological interaction or, alternatively, the metal-affinity coordination of histidine to zinc. In the case of conjugates assembled with biotin-streptavidin no significant interference with the optical and binding properties occurs whereas the histidine-zinc system appears to be affected by human plasma

    Vascular basement membranes as pathways for the passage of fluid into and out of the brain

    Get PDF
    In the absence of conventional lymphatics, drainage of interstitial fluid and solutes from the brain parenchyma to cervical lymph nodes is along basement membranes in the walls of cerebral capillaries and tunica media of arteries. Perivascular pathways are also involved in the entry of CSF into the brain by the convective influx/glymphatic system. The objective of this study is to differentiate the cerebral vascular basement membrane pathways by which fluid passes out of the brain from the pathway by which CSF enters the brain. Experiment 1: 0.5 ”l of soluble biotinylated or fluorescent AÎČ, or 1 ”l 15 nm gold nanoparticles was injected into the mouse hippocampus and their distributions determined at 5 min by transmission electron microscopy. AÎČ was distributed within the extracellular spaces of the hippocampus and within basement membranes of capillaries and tunica media of arteries. Nanoparticles did not enter capillary basement membranes from the extracellular spaces. Experiment 2: 2 ”l of 15 nm nanoparticles were injected into mouse CSF. Within 5min, groups of nanoparticles were present in the pial-glial basement membrane on the outer aspect of cortical arteries between the investing layer of pia mater and the glia limitans. The results of this study and previous research suggest that cerebral vascular basement membranes form the pathways by which fluid passes into and out of the brain but that different basement membrane layers are involved. The significance of these findings for neuroimmunology, Alzheimer's disease, drug delivery to the brain and the concept of the Virchow-Robin space are discussed

    Waveguide-Based Biosensors for Pathogen Detection

    Get PDF
    Optical phenomena such as fluorescence, phosphorescence, polarization, interference and non-linearity have been extensively used for biosensing applications. Optical waveguides (both planar and fiber-optic) are comprised of a material with high permittivity/high refractive index surrounded on all sides by materials with lower refractive indices, such as a substrate and the media to be sensed. This arrangement allows coupled light to propagate through the high refractive index waveguide by total internal reflection and generates an electromagnetic wave—the evanescent field—whose amplitude decreases exponentially as the distance from the surface increases. Excitation of fluorophores within the evanescent wave allows for sensitive detection while minimizing background fluorescence from complex, “dirty” biological samples. In this review, we will describe the basic principles, advantages and disadvantages of planar optical waveguide-based biodetection technologies. This discussion will include already commercialized technologies (e.g., Corning’s EPIC¼ Ô, SRU Biosystems’ BINDℱ, Zeptosense¼, etc.) and new technologies that are under research and development. We will also review differing assay approaches for the detection of various biomolecules, as well as the thin-film coatings that are often required for waveguide functionalization and effective detection. Finally, we will discuss reverse-symmetry waveguides, resonant waveguide grating sensors and metal-clad leaky waveguides as alternative signal transducers in optical biosensing

    Screening for psychological distress in patients with lung cancer: results of a clinical audit evaluating the use of the patient Distress Thermometer

    Get PDF
    Patients with lung cancer frequently suffer psychological distress and guidelines in the United Kingdom recommend screening of all cancer patients for this problem. The audit investigated use of the Distress Thermometer in terms of staff adherence to locally developed guidelines, patient willingness to use the tool, its impact on referral rates to clinical psychology services and concordance between the tool and the clinical assessment. Use of the Distress Thermometer was audited over a 3-month period in one lung cancer outpatient clinic. Referrals to clinical psychology services in response to clearly delineated referral indicators were assessed. Patient-reported outcomes were compared with practitioner assessment of need during clinical consultations to see whether the tool was measuring distress effectively. Thirty three of 34 patients used the Distress Thermometer during the audit period. Ten reported distress levels above 4 in the emotional or family problems domains. On ten occasions, the clinical interview identified problems not elicited by the Distress Thermometer. Guidelines were adhered to by staff, and patients were offered information about local support services and referral to clinical psychology services where indicated. Whilst all patients were happy to receive written information about further sources of support, none wanted to be referred to psychological services at that time. The Distress Thermometer is acceptable to patients with lung cancer in outpatient settings but it did not increase referrals for psychological support. Staff found it to be a useful tool in opening up communication about patient issues although it should not replace a comprehensive clinical interview
    • 

    corecore