90 research outputs found
NIRS assessment of brain hemodynamics
Near Infrared Spectroscopy (NIRS) allows for assessing brain hemodynamics non-invasively. In NIRS studies, the maneuver of breath holding is frequently used as an activation of the brain autoregulation response. However, breath holding is not always feasible or effective in the clinical practice. We explored the possibility of using kapalabathi, an ancient yoga respiration technique, as an alternate activation maneuver. We studied the brain oxygenation response to kapalabathi, in yoga practitioners, in three different postures. In all the three postures considered Kapalabathi produces a measurable effect on the oxygen availability at the brain cortex level. Remarkable differences were observed in the brain autoregulatory response of smoker and non-smoker practitioners
Joint Metabonomic and Instrumental Analysis for the Classification of Migraine Patients with 677-MTHFR Mutations
Migraine is a neurological disorder that correlates with an increased risk of cerebrovascular lesions. Genetic mutations of the MTHFR gene are correlated to migraine and to the increased risk of artery pathologies. Also, migraine patients show altered hematochemical parameters, linked to an impaired platelet aggregation mechanism. Hence, the vascular assessment of migraineurs is of primary importance
An exact mathematical description of computation with transient spatiotemporal dynamics in a complex-valued neural network
We study a complex-valued neural network (cv-NN) with linear, time-delayed
interactions. We report the cv-NN displays sophisticated spatiotemporal
dynamics, including partially synchronized ``chimera'' states. We then use
these spatiotemporal dynamics, in combination with a nonlinear readout, for
computation. The cv-NN can instantiate dynamics-based logic gates, encode
short-term memories, and mediate secure message passing through a combination
of interactions and time delays. The computations in this system can be fully
described in an exact, closed-form mathematical expression. Finally, using
direct intracellular recordings of neurons in slices from neocortex, we
demonstrate that computations in the cv-NN are decodable by living biological
neurons. These results demonstrate that complex-valued linear systems can
perform sophisticated computations, while also being exactly solvable. Taken
together, these results open future avenues for design of highly adaptable,
bio-hybrid computing systems that can interface seamlessly with other neural
networks
Custom CGH array profiling of copy number variations (CNVs) on chromosome 6p21.32 (HLA locus) in patients with venous malformations associated with multiple sclerosis
<p>Abstract</p> <p>Background</p> <p>Multiple sclerosis (MS) is a complex disorder thought to result from an interaction between environmental and genetic predisposing factors which have not yet been characterised, although it is known to be associated with the HLA region on 6p21.32. Recently, a picture of chronic cerebrospinal venous insufficiency (CCSVI), consequent to stenosing venous malformation of the main extra-cranial outflow routes (VM), has been described in patients affected with MS, introducing an additional phenotype with possible pathogenic significance.</p> <p>Methods</p> <p>In order to explore the presence of copy number variations (CNVs) within the HLA locus, a custom CGH array was designed to cover 7 Mb of the HLA locus region (6,899,999 bp; chr6:29,900,001-36,800,000). Genomic DNA of the 15 patients with CCSVI/VM and MS was hybridised in duplicate.</p> <p>Results</p> <p>In total, 322 CNVs, of which 225 were extragenic and 97 intragenic, were identified in 15 patients. 234 known polymorphic CNVs were detected, the majority of these being situated in non-coding or extragenic regions. The overall number of CNVs (both extra- and intragenic) showed a robust and significant correlation with the number of stenosing VMs (Spearman: r = 0.6590, p = 0.0104; linear regression analysis r = 0.6577, p = 0.0106).</p> <p>The region we analysed contains 211 known genes. By using pathway analysis focused on angiogenesis and venous development, MS, and immunity, we tentatively highlight several genes as possible susceptibility factor candidates involved in this peculiar phenotype.</p> <p>Conclusions</p> <p>The CNVs contained in the HLA locus region in patients with the novel phenotype of CCSVI/VM and MS were mapped in detail, demonstrating a significant correlation between the number of known CNVs found in the HLA region and the number of CCSVI-VMs identified in patients. Pathway analysis revealed common routes of interaction of several of the genes involved in angiogenesis and immunity contained within this region. Despite the small sample size in this pilot study, it does suggest that the number of multiple polymorphic CNVs in the HLA locus deserves further study, owing to their possible involvement in susceptibility to this novel MS/VM plus phenotype, and perhaps even other types of the disease.</p
Cerebral reactivity in migraine patients measured with functional near-infrared spectroscopy
Five-year survival after first-ever ischaemic stroke is worse in total anterior circulation infarcts: the SINPAC cohort.
Light emitting diode (LED) use in artificial lighting for broiler chicken production
Light emitting diode (LED) has been used in commercial poultry industry by presenting superior energy savings and providing feasibility on production process. The objective of this research was to evaluate performance and carcass yield of broiler chickens exposed to different LED colors compared with fluorescent lamps. For that, two experiments (E1 and E2) were performed and 2,646 Cobb® chickens were used. In experiment E1, male birds were exposed to 20 lux artificial lighting with red, yellow, blue, and white LED bulbs; and fluorescent bulb. In experiment E2, male and female birds were exposed to 15 lux artificial lighting with red and blue LED bulbs; and fluorescent bulb. Cumulative weight gain (kg), feed intake (kg), feed conversion, hot carcass weight (kg), carcass yield (%), and breast and thigh + drumstick yield (%) were used as response variables. Results showed no difference (p > 0.05) among treatments for performance, carcass yield, and cut yield in experiment E1. In experiment E2 there was only difference between genders (p 0,05) entre os tratamentos para desempenho e rendimento de carcaça e cortes, no experimento E1. No experimento E2, houve diferença apenas entre os sexos (p < 0,05), com machos apresentando maior ganho de peso acumulado, maior consumo de ração, maior peso de carcaça quente e maior rendimento de coxa-sobrecoxa. Pode-se concluir que a utilização de LED, nas diferentes cores, apresentou o mesmo efeito das lâmpadas fluorescentes sobre o desempenho e o rendimento de carcaça de frangos de corte.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)UNESP FMVZ Departamento de Melhoramento e Nutrição AnimalUFGD Faculdade de Ciências AgráriasUFGD FCAUNESP FMVZ Departamento de Produção AnimalUNESP FMVZ Departamento de Melhoramento e Nutrição AnimalUNESP FMVZ Departamento de Produção Anima
The size of juxtaluminal hypoechoic area in ultrasound images of asymptomatic carotid plaques predicts the occurrence of stroke
Objective: To test the hypothesis that the size of a juxtaluminal black (hypoechoic) area (JBA) in ultrasound images of asymptomatic carotid artery plaques predicts future ipsilateral ischemic stroke. Methods: A JBA was defined as an area of pixels with a grayscale value <25 adjacent to the lumen without a visible echogenic cap after image normalization. The size of a JBA was measured in the carotid plaque images of 1121 patients with asymptomatic carotid stenosis 50% to 99% in relation to the bulb (Asymptomatic Carotid Stenosis and Risk of Stroke study); the patients were followed for up to 8 years. Results: The JBA had a linear association with future stroke rate. The area under the receiver-operating characteristic curve was 0.816. Using Kaplan-Meier curves, the mean annual stroke rate was 0.4% in 706 patients with a JBA <4 mm 2, 1.4% in 171 patients with a JBA 4 to 8 mm2, 3.2% in 46 patients with a JBA 8 to 10 mm2, and 5% in 198 patients with a JBA >10 mm2 (P <.001). In a Cox model with ipsilateral ischemic events (amaurosis fugax, transient ischemic attack [TIA], or stroke) as the dependent variable, the JBA (<4 mm2, 4-8 mm2, >8 mm2) was still significant after adjusting for other plaque features known to be associated with increased risk, including stenosis, grayscale median, presence of discrete white areas without acoustic shadowing indicating neovascularization, plaque area, and history of contralateral TIA or stroke. Plaque area and grayscale median were not significant. Using the significant variables (stenosis, discrete white areas without acoustic shadowing, JBA, and history of contralateral TIA or stroke), this model predicted the annual risk of stroke for each patient (range, 0.1%-10.0%). The average annual stroke risk was <1% in 734 patients, 1% to 1.9% in 94 patients, 2% to 3.9% in 134 patients, 4% to 5.9% in 125 patients, and 6% to 10% in 34 patients. Conclusions: The size of a JBA is linearly related to the risk of stroke and can be used in risk stratification models. These findings need to be confirmed in future prospective studies or in the medical arm of randomized controlled studies in the presence of optimal medical therapy. In the meantime, the JBA may be used to select asymptomatic patients at high stroke risk for carotid endarterectomy and spare patients at low risk from an unnecessary operation
Sustainability in manufacturing processes: practices performed in metal forming, casting, heat treatment, welding and electrostatic painting
© 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group. This article aims to list the main sustainable practices developed in the processes of metal forming, casting, heat treatment, welding and electrostatic painting. When analysed the literature about sustainable manufacturing, a predominance of studies about machining is observed and the processes mentioned are few explored in academic studies. The research strategy used to reach the objective was systematic literature review, conducted for each process cited. Many sustainable practices were identified with prominence of better materials use and energy efficiency. The authors of this article believe that the information presented here can be useful for researches in their future studies and for industry professionals interested in improving manufacturing processes
- …