430 research outputs found

    Role of echocardiography in diagnosis and risk stratification in heart failure with left ventricular systolic dysfunction

    Get PDF
    Heart failure (HF) is a complex clinical syndrome that can result from any structural or functional cardiac disorder that impairs the ability of the ventricle to fill with or eject blood. Echocardiography represents the "gold standard" in the assessment of LV systolic dysfunction and in the recognition of systolic heart failure, since dilatation of the LV results in alteration of intracardiac geometry and hemodynamics leading to increased morbidity and mortality

    Identification of responders to cardiac resynchronization therapy by contractile reserve during stress echocardiography

    Get PDF
    Aims The identification of responders to cardiac resynchronization therapy (CRT) remains a challenge. We assessed the role of dyssynchrony (DYS) and contractile reserve (CR) in identifying CRT responders. Methods and results Sixty-nine patients (55% with ischaemic aetiology) referred for CRT (ejection fraction 35%, New York Heart Association III, and QRS duration 120 ms) underwent baseline evaluation of DYS and dobutamine stress-echo [up to 40 mg/kg/min: CR was defined as a wall motion score index (WMSI) variation 0.20]. CRT responders were identified by clinical and/or echocardiographic [end-systolic volume (ESV) decrease 15%] follow-up criteria. During a median follow-up of 11 months, 46 patients (66%) were classified as clinical responders. Reverse remodelling was found in 34 of the 59 patients (58%) with echocardiographic follow-up. CR was present in 78% of clinical responders (P ? 0.001) and in 69% with reverse remodelling (P ? 0.005). DYS was equally present in the two groups. Reverse remodelling was correlated with rest-stress changes in ESV (r ? 0.439, P ? 0.003) and in WMSI (r ? 0.450, P ? 0.001), but not with DYS. CR (OR ? 6.2, 95% CI ? 1.4-27.6, P ? 0.015) was the best predictor of response to CRT. Conclusion Patients with CR show a favourable clinical and reverse LV remodelling response to CRT. This finding shifts the focus from electrical (dyssynchrony) to the myocardial substrate of functional response

    Force-frequency relationship during dobutamine stress echocardiography predicts exercise tolerance and BNP levels in patients with chronic congestive heart failure

    Get PDF
    Purpose: D obutamine stress echocardiography (DSE) is widely used to evaluate myocardial contractile reserve; it provides prognostic information in patients with chronic congestive heart failure (CHF). The force?frequency relationship (FFR) is a method for evaluate LV contractility during DSE . The aim of our study is to assess the relationship among FFR, BNP levels, and aerobic exercise capacity in CHF patients. Methods and materials: 37 CHF patients (age 67?8 years, 54% with an ischemic etiology), underwent high dose DSE (up to 40 m g/kg/min). FFR was determined as a ratio between systolic cuff pressure and end-systolic volume (biplane using a Simposon rule) assessed at baseline and peak DSE . BNP levels were determined on blood samples withdrawn at baseline. After a few hours, CHF patients underwent cardiopulmonary exercise test with expired gas measurement. Results: Mean ejection fraction was 32?7% and NHYA class 2.5?0.6. FFR was directly related to peak oxygen consumption (Figure Left), LV ejection fraction (r=0.398, p=0.015) and mitral annulus peak systolic velocity (r=0.428, p=0.013). FFR was inversely related to NYHA class (r=-0.43, p=0.013), LV end-diastolic diameter (r=-0.377, p=0.022), LV intraventricular dyssynchrony (r=-0.394, p=0.016), and BNP levels (Figure Right). At multiple regression analysis, FFR (B=0.502, p= 0.004) and E/Ea ratio (B=-0.336, p=0.044) were the best predictors of exercise tolerance. Conclusions: In patients with stable CHF, impaired myocardial contractility during DSE is related to higher BNP levels and poorer exercise tolerance

    A cross-sectional study evaluating hospitalization rates for chronic limb-threatening ischemia during the COVID-19 outbreak in Campania, Italy

    Get PDF
    The expansion of coronavirus disease 2019 (COVID-19) prompted measures of disease containment by the Italian government with a national lockdown on March 9, 2020. The purpose of this study is to evaluate the rate of hospitalization and mode of in-hospital treatment of patients with chronic limb-threatening ischemia (CLTI) before and during lockdown in the Campania region of Italy. The study population includes all patients with CLTI hospitalized in Campania over a 10-week period: 5 weeks before and 5 weeks during lockdown (n = 453). Patients were treated medically and/or underwent urgent revascularization and/or major amputation of the lower extremities. Mean age was 69.2 +/- 10.6 years and 27.6% of the patients were women. During hospitalization, 21.9% of patients were treated medically, 78.1% underwent revascularization, and 17.4% required amputations. In the weeks during the lockdown, a reduced rate of hospitalization for CLTI was observed compared with the weeks before lockdown (25 vs 74/100,000 inhabitants/year; incidence rate ratio: 0.34, 95% CI 0.32-0.37). This effect persisted to the end of the study period. An increased amputation rate in the weeks during lockdown was observed (29.3% vs 13.4%; p < 0.001). This study reports a reduced rate of CLTI-related hospitalization and an increased in-hospital amputation rate during lockdown in Campania. Ensuring appropriate treatment for patients with CLTI should be prioritized, even during disease containment measures due to the COVID-19 pandemic or other similar conditions

    Prognostic value of reduced heart rate reserve during exercise in hypertrophic cardiomyopathy

    Get PDF
    Background: Sympathetic dysfunction can be evaluated by heart rate reserve (HRR) with exercise test. Objectives: To determine the value of HRR in predicting outcome of patients with hypertrophic cardiomyopathy (HCM). Methods: We enrolled 917 HCM patients (age = 49 +/- 15 years, 516 men) assessed with exercise stress echocardiography (ESE) in 11 centres. ESE modality was semi-supine bicycle in 51 patients (6%), upright bicycle in 476 (52%), and treadmill in 390 (42%). During ESE, we assessed left ventricular outflow tract obstruction (LVOTO), stress-induced new regional wall motion abnormalities (RWMA), and HRR (peak/rest heart rate, HR). By selection, all patients completed the follow-up. Mortality was the predetermined outcome measure Results: During ESE, RWMA occurred in 22 patients (2.4%) and LVOTO (>= 50 mmHg) in 281 (30.4%). HRR was 1.90 +/- 0.40 (lowest quartile 2.13). Higher resting heart rate (odds ratio 1.027, 95% CI: 1.018-1.036, p < 0.001), older age (odds ratio 1.021, 95% CI: 1.009-1.033, p < 0.001), lower exercise tolerance (mets, odds ratio 0.761, 95% CI: 0.708-0.817, p < 0.001) and resting LVOTO (odds ratio 1.504, 95% CI: 1.043-2.170, p = 0.029) predicted a reduced HRR. During a median follow-up of 89 months (interquartile range: 36-145 months), 90 all-cause deaths occurred. At multivariable analysis, lowest quartile HRR (Hazard ratio 2.354, 95% CI 1.116-4.968 p = 0.025) and RWMA (Hazard ratio 3.279, 95% CI 1.441-7.461 p = 0.004) independently predicted death, in addition to age (Hazard ratio 1.064, 95% CI 1.043-1.085 p < 0.001) and maximal wall thickness (Hazard ratio 1.081, 95% CI 1.037-1.128, p < 0.001). Conclusions: A blunted HRR during ESE predicts survival independently of RWMA in HCM patients.info:eu-repo/semantics/publishedVersio

    Quality control of B-lines analysis in stress Echo 2020

    Get PDF
    Background The effectiveness trial “Stress echo (SE) 2020” evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. Purpose To provide web-based upstream quality control and harmonization of B-lines reading criteria. Methods 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module ( http://se2020.altervista.org ). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. Results All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p < .01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p < .01). Conclusions Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly.info:eu-repo/semantics/publishedVersio

    How do cardiologists select patients for dual antiplatelet therapy continuation beyond 1 year after a myocardial infarction? Insights from the EYESHOT Post-MI Study

    Get PDF
    Background: Current guidelines suggest to consider dual antiplatelet therapy (DAPT) continuation for longer than 12 months in selected patients with myocardial infarction (MI). Hypothesis: We sought to assess the criteria used by cardiologists in daily practice to select patients with a history of MI eligible for DAPT continuation beyond 1 year. Methods: We analyzed data from the EYESHOT Post-MI, a prospective, observational, nationwide study aimed to evaluate the management of patients presenting to cardiologists 1 to 3 years from the last MI event. Results: Out of the 1633 post-MI patients enrolled in the study between March and December 2017, 557 (34.1%) were on DAPT at the time of enrolment, and 450 (27.6%) were prescribed DAPT after cardiologist assessment. At multivariate analyses, a percutaneous coronary intervention (PCI) with multiple stents and the presence of peripheral artery disease (PAD) resulted as independent predictors of DAPT continuation, while atrial fibrillation was the only independent predictor of DAPT interruption for patients both at the second and the third year from MI at enrolment and the time of discharge/end of the visit. Conclusions: Risk scores recommended by current guidelines for guiding decisions on DAPT duration are underused and misused in clinical practice. A PCI with multiple stents and a history of PAD resulted as the clinical variables more frequently associated with DAPT continuation beyond 1 year from the index MI

    On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection

    Get PDF
    A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)
    corecore