203 research outputs found
Instance-Independent View Serializability for Semistructured Databases
Semistructured databases require tailor-made concurrency control mechanisms
since traditional solutions for the relational model have been shown to be
inadequate. Such mechanisms need to take full advantage of the hierarchical
structure of semistructured data, for instance allowing concurrent updates of
subtrees of, or even individual elements in, XML documents. We present an
approach for concurrency control which is document-independent in the sense
that two schedules of semistructured transactions are considered equivalent if
they are equivalent on all possible documents. We prove that it is decidable in
polynomial time whether two given schedules in this framework are equivalent.
This also solves the view serializability for semistructured schedules
polynomially in the size of the schedule and exponentially in the number of
transactions
No-reference bitstream-based visual quality impairment detection for high definition H.264/AVC encoded video sequences
Ensuring and maintaining adequate Quality of Experience towards end-users are key objectives for video service providers, not only for increasing customer satisfaction but also as service differentiator. However, in the case of High Definition video streaming over IP-based networks, network impairments such as packet loss can severely degrade the perceived visual quality. Several standard organizations have established a minimum set of performance objectives which should be achieved for obtaining satisfactory quality. Therefore, video service providers should continuously monitor the network and the quality of the received video streams in order to detect visual degradations. Objective video quality metrics enable automatic measurement of perceived quality. Unfortunately, the most reliable metrics require access to both the original and the received video streams which makes them inappropriate for real-time monitoring. In this article, we present a novel no-reference bitstream-based visual quality impairment detector which enables real-time detection of visual degradations caused by network impairments. By only incorporating information extracted from the encoded bitstream, network impairments are classified as visible or invisible to the end-user. Our results show that impairment visibility can be classified with a high accuracy which enables real-time validation of the existing performance objectives
Dynamic estimation of specific fluxes in metabolic networks using non-linear dynamic optimization
Thickness characterization toolbox for transparent protective coatings on polymer substrates
The thickness characterization of transparent protective coatings on functional, transparent materials is often problematic. In this paper, a toolbox to determine the thicknesses of a transparent coating on functional window films is presented. The toolbox consists of a combination of secondary ion mass spectrometry and profilometry and can be transferred to other transparent polymeric materials. A coating was deposited on designed model samples, which were characterized with cross-sectional views in transmission and in scanning/transmission electron microscopy and ellipsometry. The toolbox was then used to assess the thicknesses of the protective coatings on the pilot-scale window films. This coating was synthesized using straightforward sol-gel alkoxide chemistry. The kinetics of the condensation are studied in order to obtain a precursor that allows fast drying and complete condensation after simple heat treatment. The shelf life of this precursor solution was investigated in order to verify its accordance to industrial requirements. Deposition was performed successfully at low temperatures below 100 °C, which makes deposition on polymeric foils possible. By using roll-to-roll coating, the findings of this paper are easily transferrable to industrial scale. The coating was tested for scratch resistance and adhesion. Values for the emissivity (ε) of the films were recorded to justify the use of the films obtained as infrared reflective window films. In this work, it is shown that the toolbox measures similar thicknesses to those measured by electron microscopy and can be used to set a required thickness for protective coatings
Assessing the importance of audio/video synchronization for simultaneous translation of video sequences
Lip synchronization is considered a key parameter during interactive communication. In the case of video conferencing and television broadcasting, the differential delay between audio and video should remain below certain thresholds, as recommended by several standardization bodies. However, further research has also shown that these thresholds can be relaxed, depending on the targeted application and use case. In this article, we investigate the influence of lip sync on the ability to perform real-time language interpretation during video conferencing. Furthermore, we are also interested in determining proper lip sync visibility thresholds applicable to this use case. Therefore, we conducted a subjective experiment using expert interpreters, which were required to perform a simultaneous translation, and non-experts. Our results show that significant differences are obtained when conducting subjective experiments with expert interpreters. As interpreters are primarily focused on performing the simultaneous translation, lip sync detectability thresholds are higher compared with existing recommended thresholds. As such, primary focus and the targeted application and use case are important factors to be considered when selecting proper lip sync acceptability thresholds
Town of Lisbon, Maine Annual Financial Report For The Fiscal Year Ended June 30, 2009
status: publishe
Data Standards in Audiology:A Mixed-Methods Exploration of Community Perspectives and Implementation Considerations
Objective: The purpose of this study was to explore options for data standardisation in audiology and document the global audiology community's current knowledge and views of data standards, explore their needs and preferences, and develop recommendations for data standardisation as a result. Design: A mixed-methods approach, combining a structured survey with an in-depth exploration of themes by experts during a special session on "Big Data and Data Standards in Audiology" at the 2024 Virtual Conference of Computational Audiology. Study Sample: The survey sample consisted of 82 members of the global audiology community; five experts joined the panel discussion. Results: Survey results emphasized the need for data standardisation in audiology aimed at facilitating research and improving patient care. Knowledge of existing initiatives was low: 38% were aware of initiatives. Yet, 90% envisioned contributing to them moving forward. The panel discussion explored emerging standardisation initiatives in audiology (OMOP, openEHR, HIMSA's Noah standard), challenges (e.g., data quality and privacy), and opportunities (e.g., conversion between approaches and synergies with other medical fields). Conclusions: The community support identified in this study could be leveraged to further develop standardisation initiatives for audiology, ensuring alignment between initiatives and with other medical fields
Why Are Outcomes Different for Registry Patients Enrolled Prospectively and Retrospectively? Insights from the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF).
Background: Retrospective and prospective observational studies are designed to reflect real-world evidence on clinical practice, but can yield conflicting results. The GARFIELD-AF Registry includes both methods of enrolment and allows analysis of differences in patient characteristics and outcomes that may result. Methods and Results: Patients with atrial fibrillation (AF) and ≥1 risk factor for stroke at diagnosis of AF were recruited either retrospectively (n = 5069) or prospectively (n = 5501) from 19 countries and then followed prospectively. The retrospectively enrolled cohort comprised patients with established AF (for a least 6, and up to 24 months before enrolment), who were identified retrospectively (and baseline and partial follow-up data were collected from the emedical records) and then followed prospectively between 0-18 months (such that the total time of follow-up was 24 months; data collection Dec-2009 and Oct-2010). In the prospectively enrolled cohort, patients with newly diagnosed AF (≤6 weeks after diagnosis) were recruited between Mar-2010 and Oct-2011 and were followed for 24 months after enrolment. Differences between the cohorts were observed in clinical characteristics, including type of AF, stroke prevention strategies, and event rates. More patients in the retrospectively identified cohort received vitamin K antagonists (62.1% vs. 53.2%) and fewer received non-vitamin K oral anticoagulants (1.8% vs . 4.2%). All-cause mortality rates per 100 person-years during the prospective follow-up (starting the first study visit up to 1 year) were significantly lower in the retrospective than prospectively identified cohort (3.04 [95% CI 2.51 to 3.67] vs . 4.05 [95% CI 3.53 to 4.63]; p = 0.016). Conclusions: Interpretations of data from registries that aim to evaluate the characteristics and outcomes of patients with AF must take account of differences in registry design and the impact of recall bias and survivorship bias that is incurred with retrospective enrolment. Clinical Trial Registration: - URL: http://www.clinicaltrials.gov . Unique identifier for GARFIELD-AF (NCT01090362)
- …
