9 research outputs found

    Создание развитых интернет-программ на примере построения виджет-программ

    Get PDF
    Рассмотрено применение методологии создания развитых Интернет-программ на основе Adobe Flex 2.0 с применением паттернов проектирования и архитектурного каркаса. Подход проиллюстрирован построением виджет-программ

    Mammographic positioning quality of newly trained versus experienced radiographers in the Dutch breast cancer screening programme

    No full text
    Our purpose was to compare mammographic positioning quality of new (NR) versus experienced screening radiographers (ER) in the Netherlands. Before starting to work in breast screening, NR must complete an education programme including a theoretical course (four days), practical training (six weeks), and a portfolio-review of 50 mammographic screening examinations performed by the radiographer. Furthermore, Dutch screening has an extensive system of quality assurance, including an audit-review of positioning quality of mammograms by ER. We analysed 13,520 portfolio views (NR) and 14,896 audit views (ER) based on pre-specified criteria, e.g., depiction of inframammary angle. Overall positioning was more adequate for NR than ER (CC views: 97% versus 86%, p = 0.00; MLO views: 92% versus 84%, p = 0.00). NR scored better for most of the CC-criteria and showed, for instance, less folds (inadequate: 10% versus 16%, p = 0.00). In contrast, NR encountered more difficulties for MLO views in, for example, depiction of infra-mammary angle (inadequate: 38% versus 34%, p = 0.00). Overall, mammograms from NR were more often considered adequate, because of less severe errors. NR perform better than ER in overall positioning technique. These results stress the need for continuous monitoring and training in breast screening programmes to keep positioning skills up to date. • We evaluated positioning quality of new and experienced Dutch screening radiographers. • New radiographers outperform their experienced colleagues in mammographic positioning quality. • New radiographers make less severe errors compared to experienced colleagues. • There is a need for a continuous individual monitoring and feedback syste

    Comparison of a flexible versus a rigid breast compression paddle: pain experience, projected breast area, radiation dose and technical image quality

    No full text
    To compare pain, projected breast area, radiation dose and image quality between flexible (FP) and rigid (RP) breast compression paddles. The study was conducted in a Dutch mammographic screening unit (288 women). To compare both paddles one additional image with RP was made, consisting of either a mediolateral-oblique (MLO) or craniocaudal-view (CC). Pain experience was scored using the Numeric Rating Scale (NRS). Projected breast area was estimated using computer software. Radiation dose was estimated using the model by Dance. Image quality was reviewed by three radiologists and three radiographers. There was no difference in pain experience between both paddles (mean difference NRS: 0.08 ± 0.08, p = 0.32). Mean radiation dose was 4.5 % lower with FP (0.09 ± 0.01 p = 0.00). On MLO-images, the projected breast area was 0.79 % larger with FP. Paired evaluation of image quality indicated that FP removed fibroglandular tissue from the image area and reduced contrast in the clinically relevant retroglandular area at chest wall side. Although FP performed slightly better in the projected breast area, it moved breast tissue from the image area at chest wall side. RP showed better contrast, especially in the retroglandular area. We therefore recommend the use of RP for standard MLO and CC view

    Recommendations from the European Commission Initiative on Breast Cancer for multigene testing to guide the use of adjuvant chemotherapy in patients with early breast cancer, hormone receptor positive, HER-2 negative.

    Get PDF
    BACKGROUND: Predicting the risk of recurrence and response to chemotherapy in women with early breast cancer is crucial to optimise adjuvant treatment. Despite the common practice of using multigene tests to predict recurrence, existing recommendations are inconsistent. Our aim was to formulate healthcare recommendations for the question "Should multigene tests be used in women who have early invasive breast cancer, hormone receptor-positive, HER2-negative, to guide the use of adjuvant chemotherapy?" METHODS: The European Commission Initiative on Breast Cancer (ECIBC) Guidelines Development Group (GDG), a multidisciplinary guideline panel including experts and three patients, developed recommendations informed by systematic reviews of the evidence. Grading of Recommendations Assessment, Development and Evaluation (GRADE) Evidence to Decision frameworks were used. Four multigene tests were evaluated: the 21-gene recurrence score (21-RS), the 70-gene signature (70-GS), the PAM50 risk of recurrence score (PAM50-RORS), and the 12-gene molecular score (12-MS). RESULTS: Five studies (2 marker-based design RCTs, two treatment interaction design RCTs and 1 pooled individual data analysis from observational studies) were included; no eligible studies on PAM50-RORS or 12-MS were identified and the GDG did not formulate recommendations for these tests. CONCLUSIONS: The ECIBC GDG suggests the use of the 21-RS for lymph node-negative women (conditional recommendation, very low certainty of evidence), recognising that benefits are probably larger in women at high risk of recurrence based on clinical characteristics. The ECIBC GDG suggests the use of the 70-GS for women at high clinical risk (conditional recommendation, low certainty of evidence), and recommends not using 70-GS in women at low clinical risk (strong recommendation, low certainty of evidence)

    Surgical repair of distal biceps tendon ruptures : a biomechanical comparison of two techniques

    Get PDF
    PURPOSE: To compare pain, projected breast area, radiation dose and image quality between flexible (FP) and rigid (RP) breast compression paddles. METHODS: The study was conducted in a Dutch mammographic screening unit (288 women). To compare both paddles one additional image with RP was made, consisting of either a mediolateral-oblique (MLO) or craniocaudal-view (CC). Pain experience was scored using the Numeric Rating Scale (NRS). Projected breast area was estimated using computer software. Radiation dose was estimated using the model by Dance. Image quality was reviewed by three radiologists and three radiographers. Results : There was no difference in pain experience between both paddles (mean difference NRS: 0.08 +/- 0.08, p = 0.32). Mean radiation dose was 4.5 % lower with FP (0.09 +/- 0.01 p = 0.00). On MLO-images, the projected breast area was 0.79 % larger with FP. Paired evaluation of image quality indicated that FP removed fibroglandular tissue from the image area and reduced contrast in the clinically relevant retroglandular area at chest wall side. CONCLUSIONS: Although FP performed slightly better in the projected breast area, it moved breast tissue from the image area at chest wall side. RP showed better contrast, especially in the retroglandular area. We therefore recommend the use of RP for standard MLO and CC views

    Monitoring and evaluation of breast cancer screening programmes: selecting candidate performance indicators

    Get PDF
    Background: In the scope of the European Commission Initiative on Breast Cancer (ECIBC) the Monitoring and Evaluation (M&E) subgroup was tasked to identify breast cancer screening programme (BCSP) performance indicators, including their acceptable and desirable levels, which are associated with breast cancer (BC) mortality. This paper documents the methodology used for the indicator selection. Methods: The indicators were identified through a multi-stage process. First, a scoping review was conducted to identify existing performance indicators. Second, building on existing frameworks for making well-informed health care choices, a specific conceptual framework was developed to guide the indicator selection. Third, two group exercises including a rating and ranking survey were conducted for indicator selection using pre-determined criteria, such as: relevance, measurability, accurateness, ethics and understandability. The selected indicators were mapped onto a BC screening pathway developed by the M&E subgroup to illustrate the steps of BC screening common to all EU countries. Results: A total of 96 indicators were identified from an initial list of 1325 indicators. After removing redundant and irrelevant indicators and adding those missing, 39 candidate indicators underwent the rating and ranking exercise. Based on the results, the M&E subgroup selected 13 indicators: screening coverage, participation rate, recall rate, breast cancer detection rate, invasive breast cancer detection rate, cancers > 20 mm, cancers ≤10 mm, lymph node status, interval cancer rate, episode sensitivity, time interval between screening and first treatment, benign open surgical biopsy rate, and mastectomy rate. Conclusion: This systematic approach led to the identification of 13 BCSP candidate performance indicators to be further evaluated for their association with BC mortality

    Methods for Development of the European Commission Initiative on Breast Cancer Guidelines Recommendations in the Era of Guideline Transparency

    No full text
    Neither breast cancer prevention and early-detection programs, nor their outcomes, are uniform across Europe. This article describes the rationale, methods, and process for development of the European Commission ( EC) Initiative on Breast Cancer Screening and Diagnosis Guidelines. To be consistent with standards set by the Institute of Medicine and others, the EC followed 6 general principles. First, the EC selected, via an open call, a panel with broad representation of areas of expertise. Second, it ensured that all recommendations were supported by systematic reviews. Third, the EC separately considered important subgroups of women, included patient advocates in the guidelines development group, and focused on good communication to inform women's decisions. Fourth, EC rules on conflicts of interest were followed and the GRADE ( Grading of Recommendations Assessment, Development and Evaluation) Evidence to Decision frameworks were used to structure the process and minimize the influence of competing interests. Fifth, it focused its recommendations on outcomes that matter to women, and certainty of the evidence is rated for each. Sixth, the EC elicited stakeholder feedback to ensure that the recommendations remain up to date and relevant to practice. This article describes the approach and highlights ways of disseminating and adapting the recommendations both within and outside Europe, using innovative information technology tools
    corecore