114 research outputs found

    Phase control of a longitudinal momentum entangled photon state by a deformable membrane mirror

    Full text link
    We propose a paradigmatic demonstration of the potentialities of a deformable mirror for closed-loop control of a two-photon momentum-entangled state, subject to phase fluctuations. A custom-made membrane mirror is used to set a relative phase shift between the arms of an interferometric apparatus. The control algorithm estimates the phase of the quantum state, by measurements of the coincidence events at the output ports of the interferometer, and uses the measurements results to provide a feedback signal to the deformable mirror. Stabilization of the coincidence rate to within 1.5 standard deviation of the Poissonian noise is demonstrated over 2000 seconds.Comment: RevTex, 6 page

    A Metallurgical Inspection Method to Assess the Damage in Performance-Limiting Nb3Sn Accelerator Magnet Coils

    Full text link
    The design and production of Nb3Sn-based dipole and quadrupole magnets is critical for the realization of the High-Luminosity Large Hadron Collider (HL-LHC) at the European Organization for Nuclear Research (CERN). Nb3Sn superconducting coils are aimed at enhancing the bending and focusing strengths of accelerator magnets for HL-LHC and beyond. Due to the brittle nature of Nb3Sn, the coil fabrication steps are very challenging and require very careful QA/QC. Flaws in the Nb3Sn filaments may lead to quenches, and eventually, performance limitation below nominal during magnet testing. A novel inspection method, including advanced non-destructive and destructive techniques, was developed to explore the root-causes of quenches occurring in performance-limiting coils. The most relevant results obtained for MQXF coils through this innovative inspection method are presented. This approach allows for precise assessment of the physical events associated to the quenches experienced b y magnet coils, mainly occurring under the form of damaged strands with transversely broken sub-elements. Coil-slice preparation, micro-optical observations of transverse and longitudinal cross-sections, and a deep etching technique of copper will be illustrated in the present work, with a focus on the results achieved for a CERN coil from a non-conforming quadrupole magnet prototype, and two coils fabricated in the US, in the framework of the Accelerator Upgrade Project (AUP) collaboration, from two different non-conforming quadrupole magnets, respectively. The results obtained through the proposed inspection method will be illustrated.Comment: Applied Superconductivity Conference 202

    Phylogenetic and Metabolic Tracking of Gut Microbiota during Perinatal Development

    Get PDF
    The colonization and development of gut microbiota immediately after birth is highly variable and depends on several factors, such as delivery mode and modality of feeding during the first months of life. A cohort of 31 mother and neonate pairs, including 25 at-term caesarean (CS) and 6 vaginally (V) delivered neonates (DNs), were included in this study and 121 meconium/faecal samples were collected at days 1 through 30 following birth. Operational taxonomic units (OTUs) were assessed in 69 stool samples by phylogenetic microarray HITChip and inter- and intra-individual distributions were established by inter-OTUs correlation matrices and OTUs co-occurrence or co-exclusion networks. H-1-NMR metabolites were determined in 70 stool samples, PCA analysis was performed on 55 CS DNs samples, and metabolome/OTUs co-correlations were assessed in 45 CS samples, providing an integrated map of the early microbiota OTUs-metabolome. A microbiota "core" of OTUs was identified that was independent of delivery mode and lactation stage, suggesting highly specialized communities that act as seminal colonizers of microbial networks. Correlations among OTUs, metabolites, and OTUs-metabolites revealed metabolic profiles associated with early microbial ecological dynamics, maturation of milk components, and host physiology.Peer reviewe

    Tamoxifen in treatment of hepatocellular carcinoma: a randomised controlled trial

    Get PDF
    Background Results from small randomised trials on tamoxifen in the treatment of hepatocellular carcinoma (HCC) are conflicting, We studied whether the addition of tamoxifen to best supportive care prolongs survival of patients with HCC. Methods Patients with any stage of HCC were eligible, irrespective of locoregional treatment. Randomisation was centralised, with a minimisation procedure accounting for centre, evidence of disease, and time from diagnosis. Patients were randomly allocated best supportive care alone or in addition to tamoxifen, Tamoxifen was given orally, 40 mg per day, from randomisation until death. Results 496 patients from 30 institutions were randomly allocated treatment from January, 1995, to January, 1997. Information was available for 477 patients. By Sept 15, 1997, 119 (50%) of 240 and 130 (55%) of 237 patients had died in the control and tamoxifen arms, respectively. Median survival was 16 months and 15 months (p=0.54), respectively, No differences were found within subgroups defined by prognostic variables. Relative hazard of death for patients receiving tamoxifen was 1.07 (95% CI 0.83-1.39). Interpretation Our findings show that tamoxifen is not effective in prolonging survival of patients with HCC

    Prospective validation of the CLIP score: a new prognostic system for patient with cirrhosis and hepatocellular carcinoma

    Get PDF
    Prognosis of patients with cirrhosis and hepatocellular carcinoma (HCC) depends on both residual liver function and tumor extension. The CLIP score includes Child-Pugh stage, tumor morphology and extension, serum alfa-fetoprotein (AFP) levels, and portal vein thrombosis. We externally validated the CLIP score and compared its discriminatory ability and predictive power with that of the Okuda staging system in 196 patients with cirrhosis and HCC prospectively enrolled in a randomized trial. No significant associations were found between the CLIP score and the age, sex, and pattern of viral infection. There was a strong correlation between the CLIP score and the Okuda stage, As of June 1999, 150 patients (76.5%) had died. Median survival time was 11 months, overall, and it was 36, 22, 9, 7, and 3 months for CLIP categories 0, 1, 2, 3, and 4 to 6, respectively. In multivariate analysis, the CLIP score had additional explanatory power above that of the Okuda stage. This was true for both patients treated with locoregional therapy or not. A quantitative estimation of 2-year survival predictive power showed that the CLIP score explained 37% of survival variability, compared with 21% explained by Okuda stage. In conclusion, the CLIP score, compared with the Okuda staging system, gives more accurate prognostic information, is statistically more efficient, and has a greater survival predictive power. It could be useful in treatment planning by improving baseline prognostic evaluation of patients with RCC, and could be used in prospective therapeutic trials as a stratification variable, reducing the variability of results owing to patient selection

    Magnets for a Muon Collider : Needs and Plans

    Get PDF
    We describe the magnet challenges for a Muon Collider, an exciting option considered for the future of particle physics at the energy frontier. Starting from the comprehensive work performed by the US Muon Accelerator Program, we have reviewed the performance specifications dictated by beam physics and the operating conditions to satisfy the accelerator needs. Among the many magnets that make up a muon collider, we have identified four systems that represent well the envelope of challenges: the target and capture solenoid, the final cooling solenoid, the accelerator dipoles and the collider dipoles. These systems provide focus for the development of novel concepts, largely based on HTS for reasons of performance, cost and sustainability. After giving a consolidated overview of the needs for the magnet systems, we describe here the basic technology options considered, and the plan for design and development activities.Peer reviewe

    20 T Hybrid Nb<sub>3</sub>Sn-HTS Block-Coil Accelerator Dipole With Stress-Management

    No full text
    International audienceIn the framework of studies for high energy particle colliders, design concepts for high field dipoles are being explored. In particular, relatively compact 20 T magnets can be achieved in a hybrid configuration, combining a High Temperature Superconductor (HTS) and a Low Temperature Superconductor (LTS). Preliminary concepts have been previously proposed using Bi2212 for the HTS and Nb3Sn for the LTS. One of the main difficulties of 20 T magnets is the management of the very high stresses developing during operation. The design concepts rely on a rectangular block-coil layout, which offers the advantage of aligning the conductors with the main magnetic field, therefore submitting the conductors to a perpendicular electromagnetic force for a better control of the stresses. In addition, the layout allows a specific stress management, with adequate horizontal and vertical plates to intercept the stresses. The paper presents the improvements provided to the initial concept. In terms of magnetic design, the field quality has been improved. In terms of mechanical design, the stress management has been optimized to provide a compact coil with a reduced peak stress on the HTS. Concepts for flared-end coils with joints in the coil-ends are finally presented

    Computation of the Reversible Critical Current Degradation in Nb 3_{3}Sn Rutherford Cables for Particle Accelerator Magnets

    No full text
    Superconducting coils limit current is usually measured on unloaded short samples of strands extracted from the same cable used to wound the coil. However, the critical current density of Nb3_{3}Sn strands is strongly dependent on the applied strain. This dependence is well reproduced by the so-called exponential scaling laws on strands subject to uniaxial loading. Unfortunately, no standard procedure exists to apply these laws under the complex stress condition experienced by the strands inside Rutherford cables for particle accelerator magnets. As a consequence, an empirical limit from magnet tests was set in the past: 150–200 MPa of maximum equivalent stress within the coil, considered as a block of uniform material. It is not clear how this number relates with the actual stress/strain state in the strands and if it is possible in magnet applications to infer the coil degradation from single strands tests. In this context, this paper presents a model to estimate the critical current degradation of superconducting coils as a function of the applied strain. The model results were compared against the critical current degradation measured on impregnated cable stacks subject to transverse pressure
    • …
    corecore