103 research outputs found

    A high resolution, high frame rate detector based on a microchannel plate read out with the Medipix2 counting CMOS pixel chip.

    Get PDF
    The future of ground-based optical astronomy lies with advancements in adaptive optics (AO) to overcome the limitations that the atmosphere places on high resolution imaging. A key technology for AO systems on future very large telescopes are the wavefront sensors (WFS) which detect the optical phase error and send corrections to deformable mirrors. Telescopes with >30 m diameters will require WFS detectors that have large pixel formats (512x512), low noise (<3 e-/pixel) and very high frame rates (~1 kHz). These requirements have led to the idea of a bare CMOS active pixel device (the Medipix2 chip) functioning in counting mode as an anode with noiseless readout for a microchannel plate (MCP) detector and at 1 kHz continuous frame rate. First measurement results obtained with this novel detector are presented both for UV photons and beta particles

    Mechanical and structural assessment of laboratory- and field-compacted asphalt mixtures

    Get PDF
    Compaction forms an integral part in the formation of the aggregate orientation and structure of an asphalt mixture and therefore has a profound influence on its final volumetric and mechanical performance. This article describes the influence of various forms of laboratory (gyratory, vibratory and slab-roller) and field compaction on the internal structure of asphalt specimens and subsequently on their mechanical properties, particularly stiffness and permanent deformation. A 2D image capturing and image analysis system has been used together with alternative specimen sizes and orientations to quantify the internal aggregate structure (orientation and segregation) for a range of typically used continuously graded asphalt mixtures. The results show that in terms of aggregate orientation, slab-compacted specimens tend to mimic field compaction better than gyratory and vibratory compaction. The mechanical properties of slab-compacted specimens also tend to be closer to that of field cores. However, the results also show that through careful selection of specimen size, specimen orientation and compaction variables, even mould-based compaction methods can be utilised with particular asphalt mixtures to represent field-compacted asphalt mixtures

    The Ionization of the Local Interstellar Medium, as Revealed by FUSE Observations of N, O and Ar toward White Dwarf Stars

    Get PDF
    FUSE spectra of the white dwarf stars G191-B2B, GD 394, WD 2211-495 and WD 2331-475 cover the absorption features out of the ground electronic states of N I, N II, N III, O I and Ar I in the far ultraviolet, providing new insights on the origin of the partial ionization of the Local Interstellar Medium (LISM), and for the case of G191-B2B, the interstellar cloud that immediately surrounds the solar system. Toward these targets the interstellar abundances of Ar I, and sometimes N I, are significantly below their cosmic abundances relative to H I. In the diffuse interstellar medium, these elements are not likely to be depleted onto dust grains. Generally, we expect that Ar should be more strongly ionized than H (and also O and N whose ionizations are coupled to that of H via charge exchange reactions) because the cross section for the photoionization of Ar I is very high. Our finding that Ar I/H I is low may help to explain the surprisingly high ionization of He in the LISM found by other investigators. Our result favors the interpretation that the ionization of the local medium is maintained by a strong EUV flux from nearby stars and hot gases, rather than an incomplete recovery from a past, more highly ionized condition.Comment: 13 pages, 2 figures. To appear in a special issue of the Astrophysical Journal Letters devoted to the first scientific results from the FUSE missio

    Moisture susceptibility of high and low compaction dry process crumb rubber modified asphalt mixtures

    Get PDF
    The field performance of dry process crumb rubber-modified (CRM) asphalt mixtures has been reported to be inconsistent with stripping and premature cracking on the surfacing. One of the concerns is that, because achieving field compaction of CRM material is difficult due to the inherent resilient nature of the rubber particle, nonuniform field compaction may lead to a deficient bond between rubber and bitumen. To assess the influence of compaction, a series of CRM and control mixtures was produced and compacted at two levels: 4% (low, optimum laboratory compaction) and 8% (high, field experience) air void content. The long-term durability, in regard to moisture susceptibility of the mixtures, was assessed by conducting repeated moisture conditioning cycles. Mechanical properties (stiffness, fatigue, and resistance to permanent deformation) were determined in the Nottingham Asphalt Tester. Results indicated that compared with conventional mixtures, the CRM mixtures, regardless of compaction effort, are more susceptible to moisture with the degree of susceptibility primarily depending on the amount of rubber in the mixture, rather than the difference in compaction. This behavior is different from that of conventional mixtures in which, as expected, poorly compacted mixtures were found to be more susceptible to moisture than were well-compacted mixtures

    A noiseless kilohertz frame rate imaging detector based on microchannel plates read out with the Medipix2 CMOS pixel chip

    Get PDF
    A new hybrid optical imaging detector is described that is being developed for the next generation adaptive optics (AO) wavefront sensors (WFS) for ground-based telescopes. The detector consists of a photocathode and proximity focused microchannel plates (MCPs) read out by the Medipix2 CMOS pixel ASIC. Each pixel of the Medipix2 device measures 55x55 um2 and comprises pre-amplifier, a window discriminator and a 14-bit counter. The 256x256 Medipix2 array can be read out noiselessly in 287 us. The readout can be electronically shuttered down to a temporal window of a few us. The Medipix2 is buttable on 3 sides to produce 512x(n*256) pixel devices. Measurements with ultraviolet light yield a spatial resolution of the detector at the Nyquist limit. Sub-pixel resolution can be achieved using centroiding algorithms. For the AO application, very high continuous frame rates of the order of 1 kHz are required for a matrix of 512x512 pixels. The design concepts of a parallel readout board are presented that will allow this fast data throughput. The development status of the optical WFS tube is also explained

    Possible detection of two giant extrasolar planets orbiting the eclipsing polar UZ Fornacis

    Full text link
    We present new high-speed, multi-observatory, multi-instrument photometry of the eclipsing polar UZ For in order to measure precise mid-eclipse times with the aim of detecting any orbital period variations. When combined with published eclipse times and archival data spanning ~27 years, we detect departures from a linear and quadratic trend of ~60 s. The departures are strongly suggestive of two cyclic variations of 16(3) and 5.25(25) years. The two favoured mechanisms to drive the periodicities are either two giant extrasolar planets as companions to the binary (with minimum masses of 6.3(1.5)M(Jupiter) and 7.7(1.2)M(Jupiter)) or a magnetic cycle mechanism (e.g. Applegate's mechanism) of the secondary star. Applegate's mechanism would require the entire radiant energy output of the secondary and would therefore seem to be the least likely of the two, barring any further refinements in the effect of magnetic fieilds (e.g. those of Lanza et al.). The two planet model can provide realistic solutions but it does not quite capture all of the eclipse times measurements. A highly eccentric orbit for the outer planet would fit the data nicely, but we find that such a solution would be unstable. It is also possible that the periodicities are driven by some combination of both mechanisms. Further observations of this system are encouraged.Comment: 10 pages, 4 figures, 2 table

    Microchannel Plates for the UVCS and SUMER Instruments on the SOHO Satellite

    Get PDF
    The microchannel plates for the detectors in the SUMER (Solar Ultraviolet Measurements of Emitted Radiation) and UVCS (Ultraviolet Coronograph Spectrometer) instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in late 1995 are described. A low resistance Z stack of microchannel plates (MCP's) is employed in a detector format of 27 mm x 10 mm using a multilayer cross delay line anode (XDL) with 1024 x 360 digitized pixels. The MCP stacks provide gains of greater than 2 x 10(exp 7) with good pulse height distributions (as low as 25% FWHM) under uniform flood illumination. Background rates of approx. 0.6 event cm(exp -2) sec(exp -1) are obtained for this configuration. Local counting rates up to about 800 events/pixel/sec have been achieved with little drop of the MCP gain. MCP preconditioning results are discussed, showing that some MCP stacks fail to have gain decreases when subjected to a high flux UV scrub. Also, although the bare MCP quantum efficiencies are close to those expected (10%), we found that the long wavelength response of KBr photocathodes could be substantially enhanced by the MCP scrubbing process. Flat field images are characterized by a low level of MCP fixed pattern noise and are stable. Preliminary calibration results for the instruments are shown

    Single photon imaging at ultra-high resolution

    Get PDF
    Abstract We present a detection system capable of imaging both single photon/positive ion and multiple coincidence photons/positive ions with extremely high spatial resolution. In this detector the photoelectrons excited by the incoming photons are multiplied by microchannel plate(s) (MCP). The process of multiplication is spatially constrained within an MCP pore, which can be as small as 4 μm for commercially available MCPs. An electron cloud originated by a single photoelectron is then encoded by a pixellated custom analog ASIC consisting of 105 K charge sensitive pixels of 50 μm in size arranged on a hexagonal grid. Each pixel registers the charge with an accuracy o
    corecore