121 research outputs found

    Integration of data from remote monitoring systems and programmers into the hospital electronic health record system based on international standards

    Get PDF
    Remote follow-up of implanted ICDs may offer a solution to the problem of overcrowded outpatient clinics. All major device companies have developed a remote follow-up solution. Data obtained from the remote follow-up systems are stored in a central database system, operated and owned by the device company and accessible for the physician or technician. However, the problem now arises that part of the patient’s clinical information is stored in the local electronic health record (EHR) system in the hospital, while another part is only available in the remote monitoring database. This may potentially result in patient safety issues. Ideally all information should become available in the EHR system. IHE (Integrating the Healthcare Enterprise) is an initiative to improve the way computer systems in healthcare share information. To address the requirement of integrating remote monitoring data in the local EHR, the IHE Implantable Device Cardiac Observation (IDCO) profile has been developed. In our hospital, we have implemented the IHE IDCO profile to import data from the remote databases from two device vendors into the departmental Cardiology Information System. Data are exchanged via an HL7/XML communication protocol, as defined in the IHE IDCO profile

    Recurrence of ventricular arrhythmias in ischaemic secondary prevention implantable cardioverter defibrillator recipients: long-term follow-up of the Leiden out-of-hospital cardiac arrest study (LOHCAT)

    Get PDF
    Aims to assess the long-term rate of mortality and the recurrence of potentially life-threatening ventricular arrhythmias in secondary prevention implantable cardioverter defibrillator (ICD) patients and to construct a model for baseline risk stratification.Methods and resultsSince 1996, all patients with ischaemic heart disease, receiving ICD therapy for secondary prevention of sudden death, were included in the current study. Patients were evaluated at implantation and during long-term follow-up. A total of 456 patients were included in the analysis and followed for 54 ± 35 months. During follow-up, 100 (22) patients died and ICD therapy was noted in 216 (47) patients, of which 138 (30) for fast, potentially life-threatening ventricular arrhythmia. Multivariate analysis revealed a history of atrial fibrillation or flutter (AF), ventricular tachycardia as presenting arrhythmia, and wide QRS and poor left ventricular ejection fraction as independent predictors of life-threatening ventricular arrhythmias. The strongest predictor was AF with a hazard ratio of 2.1 (95 confidence interval 1.3-3.2). On the basis of the available clinical data, it was not possible to identify a group which exhibited no risk on recurrence of potentially life-threatening ventricular arrhythmias.ConclusionIschaemic secondary prevention ICD recipients exhibit a high recurrence rate of potentially life-threatening ventricular arrhythmias. Factors that increase risk can be identified but, even with these factors, it was not possible to distinguish a recurrence-free group

    Five-year safety and efficacy of leadless pacemakers in a Dutch cohort

    Get PDF
    BACKGROUND: Adequate real-world safety and efficacy of leadless pacemakers (LPs) have been demonstrated up to 3 years after implantation. Longer-term data are warranted to assess the net clinical benefit of leadless pacing.OBJECTIVE: The purpose of this study was to evaluate the long-term safety and efficacy of LP therapy in a real-world cohort.METHODS: In this retrospective cohort study, all consecutive patients with a first LP implantation from December 21, 2012, to December 13, 2016, in 6 Dutch high-volume centers were included. The primary safety endpoint was the rate of major procedure- or device-related complications (ie, requiring surgery) at 5-year follow-up. Analyses were performed with and without Nanostim battery advisory-related complications. The primary efficacy endpoint was the percentage of patients with a pacing capture threshold ≤2.0 V at implantation and without ≥1.5-V increase at the last follow-up visit.RESULTS: A total of 179 patients were included (mean age 79 ± 9 years), 93 (52%) with a Nanostim and 86 (48%) with a Micra VR LP. Mean follow-up duration was 44 ± 26 months. Forty-one major complications occurred, of which 7 were not advisory related. The 5-year major complication rate was 4% without advisory-related complications and 27% including advisory-related complications. No advisory-related major complications occurred a median 10 days (range 0-88 days) postimplantation. The pacing capture threshold was low in 163 of 167 patients (98%) and stable in 157 of 160 (98%).CONCLUSION: The long-term major complication rate without advisory-related complications was low with LPs. No complications occurred after the acute phase and no infections occurred, which may be a specific benefit of LPs. The performance was adequate with a stable pacing capture threshold.</p

    ‘Sell[ing] what hasn’t got a name’: An exploration of the different understandings and definitions of ‘community engagement’ work in the performing arts

    Get PDF
    Widely known to promote broader involvement in the processes which define the arts and culture (Webster, 1997), community engagement work in the performing arts — despite employing a set of commonly recognised norms — has tended to be conceptualised differently both historically and contemporarily. Drawing on ethnographic research — particularly semi-structured qualitative interview accounts of numerous British practitioners with a track record of work in the sector, the article explores these different conceptualisations. The article finds that it is the actual ‘work that matters’ and not what it is named, and that the diversity of understandings and definitions among sectoral practitioners is reflective of evolving thinking, values and practice, something that may be destabilising for better or worse

    Behandeling en stigmamanagement bij opzettelijke zelfverwonding: het smalle pad tussen te veel en te weinig interveniëren

    Get PDF
    Opzettelijke zelfverwonding wordt gedefinieerd als de intentionele directe beschadiging van het eigen lichaam, zonder bewuste suïcidale intentie. De behandeling varieert van gedwongen opname in een psychiatrische instelling (in het Britse Gemenebest), tot een permissieve aanpak zonder behandeling en uiteenlopende behandelingsmogelijkheden er tussenin. Eerst wordt de gepastheid van de mate van interveniëren besproken in functie van verschillende diagnosen. Het tweede gedeelte van het artikel bespreekt het advies dat door hulpverleners verstrekt wordt aangaande de omgang met wonden en littekens en aangaande de mogelijkheden voor een (gewezen) zelfverwonder om het stigma van een deviante identiteit te vermijden. Een rondvraag bij Belgische hulpverleners bracht aan het licht dat velen onder hen adviseren om littekens te verbergen, terwijl er anderzijds aanwijzingen zijn dat niet-verbergen een teken van herstel is. Aangezien verbergen en smoesjes verzinnen ook kunnen leiden tot de instandhouding van een deviante identiteit, wordt gewezen op meer gepaste vormen van stigmamanagement

    Forward K+ production in subthreshold pA collisions at 1.0 GeV

    Get PDF
    K+ meson production in pA (A = C, Cu, Au) collisions has been studied using the ANKE spectrometer at an internal target position of the COSY-Juelich accelerator. The complete momentum spectrum of kaons emitted at forward angles, theta < 12 degrees, has been measured for a beam energy of T(p)=1.0 GeV, far below the free NN threshold of 1.58 GeV. The spectrum does not follow a thermal distribution at low kaon momenta and the larger momenta reflect a high degree of collectivity in the target nucleus.Comment: 4 pages, 3 figure

    Development and external validation of prediction models to predict implantable cardioverter-defibrillator efficacy in primary prevention of sudden cardiac death

    Get PDF
    Aims This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation.Methods and results We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1-2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0-3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality.Conclusion Although this cohort study was specifically designed to develop prediction models, risk stratification still remains challenging and no large group with insufficient benefit of ICD implantation was found. However, the prediction models have some clinical utility as we present several scenarios where ICD implantation might be postponed.Cardiolog

    Determination of hydroxyl groups in biorefinery resources via quantitative 31P NMR spectroscopy

    Get PDF
    The analysis of chemical structural characteristics of biorefinery product streams (such as lignin and tannin) has advanced substantially over the past decade, with traditional wet-chemical techniques being replaced or supplemented by NMR methodologies. Quantitative 31P NMR spectroscopy is a promising technique for the analysis of hydroxyl groups because of its unique characterization capability and broad potential applicability across the biorefinery research community. This protocol describes procedures for (i) the preparation/solubilization of lignin and tannin, (ii) the phosphitylation of their hydroxyl groups, (iii) NMR acquisition details, and (iv) the ensuing data analyses and means to precisely calculate the content of the different types of hydroxyl groups. Compared with traditional wet-chemical techniques, the technique of quantitative 31P NMR spectroscopy offers unique advantages in measuring hydroxyl groups in a single spectrum with high signal resolution. The method provides complete quantitative information about the hydroxyl groups with small amounts of sample (~30 mg) within a relatively short experimental time (~30-120 min)
    corecore