21 research outputs found

    Effect of metabolic and antioxidant supplementation on sperm parameters in oligo-astheno-teratozoospermia, with and without varicocele: a double-blind placebo-controlled study

    Get PDF
    Since sperm require high energy levels to perform their specialised function, it is vital that essential nutrients are available for spermatozoa when they develop, capacitate and acquire motility. However, they are vulnerable to a lack of energy and excess amounts of reactive oxygen species, which can impair sperm function, lead to immotility, acrosomal reaction impairment, DNA fragmentation and cell death. This monocentric, randomised, double-blind, placebo-controlled trial investigated the effect of 6 months of supplementation with l-carnitine, acetyl-l-carnitine and other micronutrients on sperm quality in 104 subjects with oligo- and/or astheno- and/or teratozoospermia with or without varicocele. In 94 patients who completed the study, sperm concentration was significantly increased in supplemented patients compared to the placebo (p =.0186). Total sperm count also increased significantly (p =.0117) in the supplemented group as compared to the placebo group. Both, progressive and total motility were higher in supplemented patients (p =.0088 and p =.0120, respectively). Although pregnancy rate was not an endpoint of the study, of the 12 pregnancies that occurred during the follow-up, 10 were reported in the supplementation group. In general, all these changes were more evident in varicocele patients. In conclusion, supplementation with metabolic and antioxidant compounds could be efficacious when included in strategies to improve fertility

    Effect of metabolic and antioxidant supplementation on sperm parameters in oligo-astheno-teratozoospermia, with and without varicocele: a double-blind placebo-controlled study

    Get PDF
    Since sperm require high energy levels to perform their specialised function, it is vital that essential nutrients are available for spermatozoa when they develop, capacitate and acquire motility. However, they are vulnerable to a lack of energy and excess amounts of reactive oxygen species, which can impair sperm function, lead to immotility, acrosomal reaction impairment, DNA fragmentation and cell death. This monocentric, randomised, double-blind, placebo-controlled trial investigated the effect of 6 months of supplementation with l-carnitine, acetyl-l- carnitine and other micronutrients on sperm quality in 104 subjects with oligo-and/ or astheno-and/ or teratozoospermia with or without varicocele. In 94 patients who completed the study, sperm concentration was significantly increased in supplemented patients compared to the placebo (p = .0186). Total sperm count also increased significantly (p = .0117) in the supplemented group as compared to the placebo group. Both, progressive and total motility were higher in supplemented patients (p = .0088 and p = .0120, respectively). Although pregnancy rate was not an endpoint of the study, of the 12 pregnancies that occurred during the follow-up, 10 were reported in the supplementation group. In general, all these changes were more evident in varicocele patients. In conclusion, supplementation with metabolic and antioxidant compounds could be efficacious when included in strategies to improve fertility

    Hyperhomocysteinemia as an early predictor of erectile dysfunction: International index of erectile function (IIEF) and penile doppler ultrasound correlation with plasma levels of homocysteine

    Get PDF
    Erectile dysfunction (ED) is inability to achieve and maintain an erection to permit satisfactory sexual activity. Homocysteine (Hcys) is a sulfur-containing amino acid synthesized from the essential amino acid methionine. Experimental models have elucidated the role of hyperhomocysteinemia (HHcys) as a strong and independent predictor for atherosclerosis progression and impaired cavernosal perfusion. The aim of this study is to investigate the serum levels of Hcys in our cohort of patients with ED, to compare these values with these of control population and to examine Hcys as a predictive marker for those patients who are beginning to complain mild-moderate ED. A total of 431 patients were enrolled in the study. The whole cohort was asked to complete the International Index of Erectile Function (IIEF) questionnaire. The study population was divided in 3 main groups: Group A: 145 patients with no ED serving as a control group; Group B: 145 patients with mild or mild-moderate ED; Group C: 141 patients with moderate or severe ED. Each participant underwent blood analysis. All patients underwent baseline and dynamic penile Doppler ultrasonography. We found in our cohort mean Hcys plasma concentrations significantly higher than the cut-off point in both groups B and C (18.6 ± 4.7 and 28.38 ± 7.8, respectively). Mean IIEF score was 27.9 ± 1.39, 19.5 ± 2.6, and 11.1 ± 2.5 for groups A, B, and C, respectively (P < 0.0001). In the penile Doppler ultrasonography studies, a high significant inverse correlation was detected between the mean values of the 10th minute's peak-systolic velocity (PSV) and Hcys levels for the groups B and C. This establishes a dose-dependent association between Hcys and ED. Furthermore, we showed that Hcys was an earlier predictor of ED than Doppler studies, as the Hcys increase was present in patients with mild ED even before abnormal Doppler values

    Association of kidney disease measures with risk of renal function worsening in patients with type 1 diabetes

    Get PDF
    Background: Albuminuria has been classically considered a marker of kidney damage progression in diabetic patients and it is routinely assessed to monitor kidney function. However, the role of a mild GFR reduction on the development of stage 653 CKD has been less explored in type 1 diabetes mellitus (T1DM) patients. Aim of the present study was to evaluate the prognostic role of kidney disease measures, namely albuminuria and reduced GFR, on the development of stage 653 CKD in a large cohort of patients affected by T1DM. Methods: A total of 4284 patients affected by T1DM followed-up at 76 diabetes centers participating to the Italian Association of Clinical Diabetologists (Associazione Medici Diabetologi, AMD) initiative constitutes the study population. Urinary albumin excretion (ACR) and estimated GFR (eGFR) were retrieved and analyzed. The incidence of stage 653 CKD (eGFR < 60 mL/min/1.73 m2) or eGFR reduction > 30% from baseline was evaluated. Results: The mean estimated GFR was 98 \ub1 17 mL/min/1.73m2 and the proportion of patients with albuminuria was 15.3% (n = 654) at baseline. About 8% (n = 337) of patients developed one of the two renal endpoints during the 4-year follow-up period. Age, albuminuria (micro or macro) and baseline eGFR < 90 ml/min/m2 were independent risk factors for stage 653 CKD and renal function worsening. When compared to patients with eGFR > 90 ml/min/1.73m2 and normoalbuminuria, those with albuminuria at baseline had a 1.69 greater risk of reaching stage 3 CKD, while patients with mild eGFR reduction (i.e. eGFR between 90 and 60 mL/min/1.73 m2) show a 3.81 greater risk that rose to 8.24 for those patients with albuminuria and mild eGFR reduction at baseline. Conclusions: Albuminuria and eGFR reduction represent independent risk factors for incident stage 653 CKD in T1DM patients. The simultaneous occurrence of reduced eGFR and albuminuria have a synergistic effect on renal function worsening

    Test beam performance measurements for the Phase I upgrade of the CMS pixel detector

    Get PDF
    A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is (99.95 ± 0.05) %, while the intrinsic spatial resolutions are (4.80 ± 0.25) μm and (7.99 ± 0.21) μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.Peer reviewe

    Learning Unbiased Representations via Mutual Information Backpropagation

    No full text
    We are interested in learning data-driven representations that can generalize well, even when trained on inherently biased data. In particular, we face the case where some attributes (bias) of the data, if learned by the model, can severely compromise its generalization properties. We tackle this problem through the lens of information theory, leveraging recent findings for a differentiable estimation of mutual information. We propose a novel end-to-end optimization strategy, which simultaneously estimates and minimizes the mutual information between the learned representation and specific data attributes. When applied on standard benchmarks, our model shows comparable or superior classification performance with respect to state-of-the-art approaches. Moreover, our method is general enough to be applicable to the problem of "algorithmic fairness", with competitive results

    Generative pseudo-label refinement for unsupervised domain adaptation

    No full text
    We investigate and characterize the inherent resilience of conditional Generative Adversarial Networks (cGANs) against noise in their conditioning labels, and exploit this fact in the context of Unsupervised Domain Adaptation (UDA). In UDA, a classifier trained on the labelled source set can be used to infer pseudo-labels on the unlabelled target set. However, this will result in a significant amount of misclassified examples (due to the well-known domain shift issue), which can be interpreted as noise injection in the ground-truth labels for the target set. We show that cGANs are, to some extent, robust against such "shift noise". Indeed, cGANs trained with noisy pseudo-labels, are able to filter such noise and generate cleaner target samples. We exploit this finding in an iterative procedure where a generative model and a classifier are jointly trained: in turn, the generator allows to sample cleaner data from the target distribution, and the classifier allows to associate better labels to target samples, progressively refining target pseudo-labels. Results on common benchmarks show that our method performs better or comparably with the unsupervised domain adaptation state of the art

    Estimation and characterisation of budesonide tablets impurities

    No full text
    Budesonide is the 16alpha,17alpha-acetal of 16alpha-hydroxyprednisolone with n-butyraldehyde, endowed with anti-inflammatory activity. In a sample of budesonide tablets, kept for three years at 25 \ub0C and 60% RH unknown impurities, not reported in European Pharmacopoiea, were present. Their identification was achieved by means of chemical and spectroscopic methods
    corecore