287 research outputs found

    Adaptive estimation in circular functional linear models

    Get PDF
    We consider the problem of estimating the slope parameter in circular functional linear regression, where scalar responses Y1,...,Yn are modeled in dependence of 1-periodic, second order stationary random functions X1,...,Xn. We consider an orthogonal series estimator of the slope function, by replacing the first m theoretical coefficients of its development in the trigonometric basis by adequate estimators. Wepropose a model selection procedure for m in a set of admissible values, by defining a contrast function minimized by our estimator and a theoretical penalty function; this first step assumes the degree of ill posedness to be known. Then we generalize the procedure to a random set of admissible m's and a random penalty function. The resulting estimator is completely data driven and reaches automatically what is known to be the optimal minimax rate of convergence, in term of a general weighted L2-risk. This means that we provide adaptive estimators of both the slope function and its derivatives

    Measurement of shower development and its Moli\`ere radius with a four-plane LumiCal test set-up

    Get PDF
    A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Moli\`ere radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.Comment: Paper published in Eur. Phys. J., includes 25 figures and 3 Table

    Heterostructures based on small molecules organic compounds

    Get PDF
    Heterostructures with layers from small molecules organic compounds were deposited on ITO/glass substrate by thermal vacuum evaporation (TVE) technique. Structural, optical and morphological investigations were carried out on the realisedlayers (zinc phthalocyanine - ZnPc, fullerene - C60 and 1,4,5,8-naphthalene - tetracarboxylic dianhydride - NTCDA). The films are polycrystalline keeping the morphological features characteristic to these materials. The prepared hetero structures reveal a large absorption domain in the visible domain. The current-voltage (I-V) characteristics of the investigated structures, recorded in dark, present an improvement in the current value (~one order of magnitude) for the standard structure (ITO/PEDOT:PSS/ZnPc/C60/NTCDA/Al) with a supplimentary layer of poly(3,4 ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS). For the inverted structure (Al/NTCD/C60/ZnPc/ITO) was also noticed an increased curent value in comparasion with that observed for the standard structure

    ECFA Detector R&D Panel, Review Report

    Full text link
    Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 103^{-3} at the ILC and 102^{-2} at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.Comment: 61 pages, 51 figure

    Magnetic resonance mammography in the evaluation of recurrence at the prior lumpectomy site after conservative surgery and radiotherapy

    Get PDF
    INTRODUCTION: The aim was to assess the value of magnetic resonance mammography (MRM) in the detection of recurrent breast cancer on the prior lumpectomy site in patients with previous conservative surgery and radiotherapy. METHODS: Between April 1999 and July 2003, 93 consecutive patients with breast cancer treated with conservative surgery and radiotherapy underwent MRM, when a malignant lesion on the site of lumpectomy was suspected by ultrasound and/or mammography. MRM scans were evaluated by morphological and dynamic characteristics. MRM diagnosis was compared with histology or with a 36-month imaging follow-up. Enhancing areas independent of the prior lumpectomy site, incidentally detected during the MRM, were also evaluated. RESULTS: MRM findings were compared with histology in 29 patients and with a 36-month follow-up in 64 patients. MRM showed 90% sensitivity, 91.6% specificity, 56.3% positive predictive value and 98.7% negative predictive value for detection of recurrence on the surgical scar. MRM detected 13 lesions remote from the scar. The overall sensitivity, specificity, positive predictive value and negative predictive value of MRM for detection of breast malignancy were 93.8%, 90%, 62.5% and 98.8%, respectively. CONCLUSION: MRM is a sensitive method to differentiate recurrence from post-treatment changes at the prior lumpectomy site after conservative surgery and radiation therapy. The high negative predictive value of this technique can avoid unnecessary biopsies or surgical treatments

    Highlights from the Pierre Auger Observatory

    Full text link
    The Pierre Auger Observatory is the world's largest cosmic ray observatory. Our current exposure reaches nearly 40,000 km2^2 str and provides us with an unprecedented quality data set. The performance and stability of the detectors and their enhancements are described. Data analyses have led to a number of major breakthroughs. Among these we discuss the energy spectrum and the searches for large-scale anisotropies. We present analyses of our Xmax_{max} data and show how it can be interpreted in terms of mass composition. We also describe some new analyses that extract mass sensitive parameters from the 100% duty cycle SD data. A coherent interpretation of all these recent results opens new directions. The consequences regarding the cosmic ray composition and the properties of UHECR sources are briefly discussed.Comment: 9 pages, 12 figures, talk given at the 33rd International Cosmic Ray Conference, Rio de Janeiro 201

    Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics

    Get PDF
    A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN

    Increased power by harmonizing structural MRI site differences with the ComBat batch adjustment method in ENIGMA

    Get PDF
    A common limitation of neuroimaging studies is their small sample sizes. To overcome this hurdle, the Enhancing Neuro Imaging Genetics through Meta-Analysis (ENIGMA) Consortium combines neuroimaging data from many institutions worldwide. However, this introduces heterogeneity due to different scanning devices and sequences. ENIGMA projects commonly address this heterogeneity with random-effects meta-analysis or mixed-effects mega-analysis. Here we tested whether the batch adjustment method, ComBat, can further reduce site-related heterogeneity and thus increase statistical power. We conducted random-effects meta-analyses, mixed-effects mega-analyses and ComBat mega-analyses to compare cortical thickness, surface area and subcortical volumes between 2897 individuals with a diagnosis of schizophrenia and 3141 healthy controls from 33 sites. Specifically, we compared the imaging data between individuals with schizophrenia and healthy controls, covarying for age and sex. The use of ComBat substantially increased the statistical significance of the findings as compared to random-effects meta-analyses. The findings were more similar when comparing ComBat with mixed-effects mega-analysis, although ComBat still slightly increased the statistical significance. ComBat also showed increased statistical power when we repeated the analyses with fewer sites. Results were nearly identical when we applied the ComBat harmonization separately for cortical thickness, cortical surface area and subcortical volumes. Therefore, we recommend applying the ComBat function to attenuate potential effects of site in ENIGMA projects and other multi-site structural imaging work. We provide easy-to-use functions in R that work even if imaging data are partially missing in some brain regions, and they can be trained with one data set and then applied to another (a requirement for some analyses such as machine learning)

    Breast MRI: guidelines from the European Society of Breast Imaging

    Get PDF
    The aim of breast MRI is to obtain a reliable evaluation of any lesion within the breast. It is currently always used as an adjunct to the standard diagnostic procedures of the breast, i.e., clinical examination, mammography and ultrasound. Whereas the sensitivity of breast MRI is usually very high, specificity—as in all breast imaging modalities—depends on many factors such as reader expertise, use of adequate techniques and composition of the patient cohorts. Since breast MRI will always yield MR-only visible questionable lesions that require an MR-guided intervention for clarification, MRI should only be offered by institutions that can also offer a MRI-guided breast biopsy or that are in close contact with a site that can perform this type of biopsy for them. Radiologists involved in breast imaging should ensure that they have a thorough knowledge of the MRI techniques that are necessary for breast imaging, that they know how to evaluate a breast MRI using the ACR BI-RADS MRI lexicon, and most important, when to perform breast MRI. This manuscript provides guidelines on the current best practice for the use of breast MRI, and the methods to be used, from the European Society of Breast Imaging (EUSOBI)
    corecore