103 research outputs found
Evaluation of polyneuropathy markers in type 1 diabetic kidney transplant patients and effects of islet transplantation: Neurophysiological and skin biopsy longitudinal analysis
OBJECTIVE - The purpose of this study was to evaluate whether islet transplantation may stabilize polyneuropathy in uremic type 1 diabetic patients (end-stage renal disease [ESRD] and type 1 diabetes), who received a successful islet-after-kidney transplantation (KI-s). RESEARCH DESIGN AND METHODS - Eighteen KI-s patients underwent electroneurographic tests of sural, peroneal, ulnar, and median nerves: the nerve conduction velocity (NCV) index and amplitudes of both sensory action potentials (SAPs) and compound motor action potentials (CMAPs) were analyzed longitudinally at 2, 4, and 6 years after islet transplantation. Skin content of advanced glycation end products (AGEs) and expression of their specific receptors (RAGE) were also studied at the 4-year follow-up. Nine patients with ESRD and type 1 diabetes who received kidney transplantation alone (KD) served as control subjects. RESULTS - The NCV score improved in the KI-s group up to the 4-year time point (P = 0.01 versus baseline) and stabilized 2 years later, whereas the same parameter did not change significantly in the KD group throughout the follow-up period or when a cross-sectional analysis between groups was performed. Either SAP or CMAP amplitudes recovered in the KI-s group, whereas they continued worsening in KD control subjects. AGE and RAGE levels in perineurium and vasa nervorum of skin biopsies were lower in the KI-s than in the KD group (P < 0.01 for RAGE). CONCLUSIONS - Islet transplantation seems to prevent long-term worsening of polyneuropathy in patients with ESRD and type 1 diabetes who receive islets after kidney transplantation. No statistical differences between the two groups were evident on cross-sectional analysis. A reduction in AGE/RAGE expression in the peripheral nervous system was shown in patients receiving islet transplantation. © 2007 by the American Diabetes Association
Frequency-modulated electromagnetic neural stimulation (FREMS) as a treatment for symptomatic diabetic neuropathy: results from a double-blind, randomised, multicentre, long-term, placebo-controlled clinical trial
AIMS/HYPOTHESIS: The aim was to evaluate the efficacy and safety of
transcutaneous frequency-modulated electromagnetic neural stimulation (frequency
rhythmic electrical modulation system, FREMS) as a treatment for symptomatic
peripheral neuropathy in patients with diabetes mellitus.
METHODS: This was a double-blind, randomised, multicentre, parallel-group study
of three series, each of ten treatment sessions of FREMS or placebo administered
within 3 weeks, 3 months apart, with an overall follow-up of about 51 weeks. The
primary endpoint was the change in nerve conduction velocity (NCV) of deep
peroneal, tibial and sural nerves. Secondary endpoints included the effects of
treatment on pain, tactile, thermal and vibration sensations. Patients eligible
to participate were aged 18-75 years with diabetes for ≥ 1 year, HbA(1c) <11.0%
(97 mmol/mol), with symptomatic diabetic polyneuropathy at the lower extremities
(i.e. abnormal amplitude, latency or NCV of either tibial, deep peroneal or sural
nerve, but with an evocable potential and measurable NCV of the sural nerve), a
Michigan Diabetes Neuropathy Score ≥ 7 and on a stable dose of medications for
diabetic neuropathy in the month prior to enrolment. Data were collected in an
outpatient setting. Participants were allocated to the FREMS or placebo arm (1:1
ratio) according to a sequence generated by a computer random number generator,
without block or stratification factors. Investigators digitised patients' date
of birth and site number into an interactive voice recording system to obtain the
assigned treatment. Participants, investigators conducting the trial, or people
assessing the outcomes were blinded to group assignment.
RESULTS: Patients (n = 110) with symptomatic neuropathy were randomised to FREMS
(n = 54) or placebo (n = 56). In the intention-to-treat population (50 FREMS, 51
placebo), changes in NCV of the three examined nerves were not different between
FREMS and placebo (deep peroneal [means ± SE]: 0.74 ± 0.71 vs 0.06 ± 1.38 m/s;
tibial: 2.08 ± 0.84 vs 0.61 ± 0.43 m/s; and sural: 0.80 ± 1.08 vs -0.91 ± 1.13
m/s; FREMS vs placebo, respectively). FREMS induced a significant reduction in
day and night pain as measured by a visual analogue scale immediately after each
treatment session, although this beneficial effect was no longer measurable 3
months after treatment. Compared with the placebo group, in the FREMS group the
cold sensation threshold was significantly improved, while non-significant
differences were observed in the vibration and warm sensation thresholds. No
relevant side effects were recorded during the study.
CONCLUSIONS/INTERPRETATION: FREMS proved to be a safe treatment for symptomatic
diabetic neuropathy, with immediate, although transient, reduction in pain, and
no effect on NCV.
TRIAL REGISTRATION: ClinicalTrials.gov NCT01628627.
FUNDING: The clinical trial was sponsored by Lorenz Biotech (Medolla, Italy),
lately Lorenz Lifetech (Ozzano dell'Emilia, Italy)
Guillain-Barré syndrome and COVID-19: an observational multicentre study from two Italian hotspot regions
Objective: Single cases and small series of Guillain-Barré syndrome (GBS) have been reported during the SARS-CoV-2 outbreak worldwide. We evaluated incidence and clinical features of GBS in a cohort of patients from two regions of northern Italy with the highest number of patients with COVID-19. Methods: GBS cases diagnosed in 12 referral hospitals from Lombardy and Veneto in March and April 2020 were retrospectively collected. As a control population, GBS diagnosed in March and April 2019 in the same hospitals were considered. Results: Incidence of GBS in March and April 2020 was 0.202/100 000/month (estimated rate 2.43/100 000/year) vs 0.077/100 000/month (estimated rate 0.93/100 000/year) in the same months of 2019 with a 2.6-fold increase. Estimated incidence of GBS in COVID-19-positive patients was 47.9/100 000 and in the COVID-19-positive hospitalised patients was 236/100 000. COVID-19-positive patients with GBS, when compared with COVID-19-negative subjects, showed lower MRC sum score (26.3±18.3 vs 41.4±14.8, p=0.006), higher frequency of demyelinating subtype (76.6% vs 35.3%, p=0.011), more frequent low blood pressure (50% vs 11.8%, p=0.017) and higher rate of admission to intensive care unit (66.6% vs 17.6%, p=0.002). Conclusions: This study shows an increased incidence of GBS during the COVID-19 outbreak in northern Italy, supporting a pathogenic link. COVID-19-associated GBS is predominantly demyelinating and seems to be more severe than non-COVID-19 GBS, although it is likely that in some patients the systemic impairment due to COVID-19 might have contributed to the severity of the whole clinical picture
The CARMENES search for exoplanets around M dwarfs. Two temperate Earth-mass planet candidates around Teegarden’s Star
Context.Teegarden’s Star is the brightest and one of the nearest ultra-cool dwarfs in the solar neighbourhood. For its late spectral type (M7.0 V),the star shows relatively little activity and is a prime target for near-infrared radial velocity surveys such as CARMENES.Aims.As part of the CARMENES search for exoplanets around M dwarfs, we obtained more than 200 radial-velocity measurements of Teegarden’sStar and analysed them for planetary signals.Methods.We find periodic variability in the radial velocities of Teegarden’s Star. We also studied photometric measurements to rule out stellarbrightness variations mimicking planetary signals.Results.We find evidence for two planet candidates, each with 1.1M⊕minimum mass, orbiting at periods of 4.91 and 11.4 d, respectively. Noevidence for planetary transits could be found in archival and follow-up photometry. Small photometric variability is suggestive of slow rotationand old age.Conclusions.The two planets are among the lowest-mass planets discovered so far, and they are the first Earth-mass planets around an ultra-cooldwarf for which the masses have been determined using radial velocities.We thank the referee Rodrigo Díaz for a careful review andhelpful comments. M.Z. acknowledges support from the Deutsche Forschungs-gemeinschaft under DFG RE 1664/12-1 and Research Unit FOR2544 “BluePlanets around Red Stars”, project no. RE 1664/14-1. CARMENES isan instrument for the Centro Astronómico Hispano-Alemán de Calar Alto(CAHA, Almería, Spain). CARMENES is funded by the German Max-Planck-Gesellschaft (MPG), the Spanish Consejo Superior de InvestigacionesCientíficas (CSIC), the European Union through FEDER/ERF FICTS-2011-02 funds, and the members of the CARMENES Consortium (Max-Planck-Institut für Astronomie, Instituto de Astrofísica de Andalucía, LandessternwarteKönigstuhl, Institut de Ciències de l’Espai, Institut für Astrophysik Göttingen,Universidad Complutense de Madrid, Thüringer Landessternwarte Tautenburg,Instituto de Astrofísica de Canarias, Hamburger Sternwarte, Centro de Astro-biología and Centro Astronómico Hispano-Alemán), with additional contribu-tions by the Spanish Ministry of Economy, the German Science Foundationthrough the Major Research Instrumentation Programme and DFG ResearchUnit FOR2544 “Blue Planets around Red Stars”, the Klaus Tschira Stiftung, thestates of Baden-Württemberg and Niedersachsen, and by the Junta de Andalucía.Based on data from the CARMENES data archive at CAB (INTA-CSIC). Thisarticle is based on observations made with the MuSCAT2 instrument, devel-oped by ABC, at Telescopio Carlos Sánchez operated on the island of Tener-ife by the IAC in the Spanish Observatorio del Teide. Data were partly col-lected with the 150-cm and 90-cm telescopes at the Sierra Nevada Observa-tory (SNO) operated by the Instituto de Astrofísica de Andalucía (IAA-CSIC).Data were partly obtained with the MONET/South telescope of the MOnitoringNEtwork of Telescopes, funded by the Alfried Krupp von Bohlen und HalbachFoundation, Essen, and operated by the Georg-August-Universität Göttingen,the McDonald Observatory of the University of Texas at Austin, and the SouthAfrican Astronomical Observatory. We acknowledge financial support from theSpanish Agencia Estatal de Investigación of the Ministerio de Ciencia, Inno-vación y Universidades and the European FEDER/ERF funds through projectsAYA2015-69350-C3-2-P, AYA2016-79425-C3-1/2/3-P, AYA2018-84089, BES-2017-080769, BES-2017-082610, ESP2015-65712-C5-5-R, ESP2016-80435-C2-1/2-R, ESP2017-87143-R, ESP2017-87676-2-2, ESP2017-87676-C5-1/2/5-R, FPU15/01476, RYC-2012-09913, the Centre of Excellence ”Severo Ochoa”and ”María de Maeztu” awards to the Instituto de Astrofísica de Canarias (SEV-2015-0548), Instituto de Astrofísica de Andalucía (SEV-2017-0709), and Cen-tro de Astrobiología (MDM-2017-0737), the Generalitat de Catalunya throughCERCA programme”, the Deutsches Zentrum für Luft- und Raumfahrt throughgrants 50OW0204 and 50OO1501, the European Research Council through grant694513, the Italian Ministero dell’instruzione, dell’università de della ricerca andUniversità degli Studi di Roma Tor Vergata through FFABR 2017 and “Mis-sion: Sustainability 2016”, the UK Science and Technology Facilities Council through grant ST/P000592/1, the Israel Science Foundation through grant848/16, the Chilean CONICYT-FONDECYT through grant 3180405, the Mexi-can CONACYT through grant CVU 448248, the JSPS KAKENHI through grantsJP18H01265 and 18H05439, and the JST PRESTO through grant JPMJPR1775
Spin Density Matrix Elements in Exclusive Meson Muoproduction
We report on a measurement of Spin Density Matrix Elements (SDMEs) in hard
exclusive meson muoproduction at COMPASS using 160~GeV/ polarised
and beams impinging on a liquid hydrogen target. The
measurement covers the kinematic range 5.0~GeV/ 17.0~GeV/,
1.0 (GeV/) 10.0 (GeV/) and 0.01 (GeV/) 0.5 (GeV/). Here, denotes the mass of the final
hadronic system, the virtuality of the exchanged photon, and
the transverse momentum of the meson with respect to the
virtual-photon direction. The measured non-zero SDMEs for the transitions of
transversely polarised virtual photons to longitudinally polarised vector
mesons () indicate a violation of -channel helicity
conservation. Additionally, we observe a dominant contribution of
natural-parity-exchange transitions and a very small contribution of
unnatural-parity-exchange transitions, which is compatible with zero within
experimental uncertainties. The results provide important input for modelling
Generalised Parton Distributions (GPDs). In particular, they may allow one to
evaluate in a model-dependent way the role of parton helicity-flip GPDs in
exclusive production
Collins and Sivers transverse-spin asymmetries in inclusive muoproduction of mesons
The production of vector mesons in deep inelastic scattering is an
interesting yet scarsely explored channel to study the transverse spin
structure of the nucleon and the related phenomena. The COMPASS collaboration
has performed the first measurement of the Collins and Sivers asymmetries for
inclusively produced mesons. The analysis is based on the data set
collected in deep inelastic scattering in using a
beam impinging on a transversely polarized target. The
mesons are selected from oppositely charged hadron pairs, and the
asymmetries are extracted as a function of the Bjorken- variable, the
transverse momentum of the pair and the fraction of the energy carried by
the pair. Indications for positive Collins and Sivers asymmetries are observed
What is the role of the placebo effect for pain relief in neurorehabilitation? Clinical implications from the Italian Consensus Conference on Pain in Neurorehabilitation
Background: It is increasingly acknowledged that the outcomes of medical treatments are influenced by the context of the clinical encounter through the mechanisms of the placebo effect. The phenomenon of placebo analgesia might be exploited to maximize the efficacy of neurorehabilitation treatments. Since its intensity varies across neurological disorders, the Italian Consensus Conference on Pain in Neurorehabilitation (ICCP) summarized the studies on this field to provide guidance on its use. Methods: A review of the existing reviews and meta-analyses was performed to assess the magnitude of the placebo effect in disorders that may undergo neurorehabilitation treatment. The search was performed on Pubmed using placebo, pain, and the names of neurological disorders as keywords. Methodological quality was assessed using a pre-existing checklist. Data about the magnitude of the placebo effect were extracted from the included reviews and were commented in a narrative form. Results: 11 articles were included in this review. Placebo treatments showed weak effects in central neuropathic pain (pain reduction from 0.44 to 0.66 on a 0-10 scale) and moderate effects in postherpetic neuralgia (1.16), in diabetic peripheral neuropathy (1.45), and in pain associated to HIV (1.82). Moderate effects were also found on pain due to fibromyalgia and migraine; only weak short-term effects were found in complex regional pain syndrome. Confounding variables might have influenced these results. Clinical implications: These estimates should be interpreted with caution, but underscore that the placebo effect can be exploited in neurorehabilitation programs. It is not necessary to conceal its use from the patient. Knowledge of placebo mechanisms can be used to shape the doctor-patient relationship, to reduce the use of analgesic drugs and to train the patient to become an active agent of the therapy
CARMENES: high-resolution spectra and precise radial velocities in the red and infrared
SPIE Astronomical Telescopes + Instrumentation (2018, Austin, Texas, United States
- …