238 research outputs found

    Evaluation of Sexual Communication Message Strategies

    Get PDF
    Parent-child communication about sex is an important proximal reproductive health outcome. But while campaigns to promote it such as the Parents Speak Up National Campaign (PSUNC) have been effective, little is known about how messages influence parental cognitions and behavior. This study examines which message features explain responses to sexual communication messages

    Evaluation of Sexual Communication Message Strategies

    Get PDF
    Parent-child communication about sex is an important proximal reproductive health outcome. But while campaigns to promote it such as the Parents Speak Up National Campaign (PSUNC) have been effective, little is known about how messages influence parental cognitions and behavior. This study examines which message features explain responses to sexual communication messages

    Automated inter-rater reliability assessment and electronic data collection in a multi-center breast cancer study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The choice between paper data collection methods and electronic data collection (EDC) methods has become a key question for clinical researchers. There remains a need to examine potential benefits, efficiencies, and innovations associated with an EDC system in a multi-center medical record review study.</p> <p>Methods</p> <p>A computer-based automated menu-driven system with 658 data fields was developed for a cohort study of women aged 65 years or older, diagnosed with invasive histologically confirmed primary breast cancer (N = 1859), at 6 Cancer Research Network sites. Medical record review with direct data entry into the EDC system was implemented. An inter-rater and intra-rater reliability (IRR) system was developed using a modified version of the EDC.</p> <p>Results</p> <p>Automation of EDC accelerated the flow of study information and resulted in an efficient data collection process. Data collection time was reduced by approximately four months compared to the project schedule and funded time available for manuscript preparation increased by 12 months. In addition, an innovative modified version of the EDC permitted an automated evaluation of inter-rater and intra-rater reliability across six data collection sites.</p> <p>Conclusion</p> <p>Automated EDC is a powerful tool for research efficiency and innovation, especially when multiple data collection sites are involved.</p

    Implementing an innovative consent form: the PREDICT experience

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In the setting of coronary angiography, generic consent forms permit highly variable communication between patients and physicians. Even with the existence of multiple risk models, clinicians have been unable to readily access them and thus provide patients with vague estimations regarding risks of the procedure.</p> <p>Methods</p> <p>We created a web-based vehicle, PREDICT, for embedding patient-specific estimates of risk from validated multivariable models into individualized consent documents at the point-of-care. Beginning August 2006, outpatients undergoing coronary angiography at the Mid America Heart Institute received individualized consent documents generated by PREDICT. In February 2007 this approach was expanded to all patients undergoing coronary angiography within the four Kansas City hospitals of the Saint Luke's Health System. Qualitative research methods were used to identify the implementation challenges and successes with incorporating PREDICT-enhanced consent documents into routine clinical care from multiple perspectives: administration, information systems, nurses, physicians, and patients.</p> <p>Results</p> <p>Most clinicians found usefulness in the tool (providing clarity and educational value for patients) and satisfaction with the altered processes of care, although a few cardiologists cited delayed patient flow and excessive patient questions. The responses from administration and patients were uniformly positive. The key barrier was related to informatics.</p> <p>Conclusion</p> <p>This preliminary experience suggests that successful change in clinical processes and organizational culture can be accomplished through multidisciplinary collaboration. A randomized trial of PREDICT consent, leveraging the accumulated knowledge from this first experience, is needed to further evaluate its impact on medical decision-making, patient compliance, and clinical outcomes.</p

    Functional and molecular characterization of hyposensitive underactive bladder tissue and urine in streptozotocin-induced diabetic rat

    Get PDF
    Background: The functional and molecular alterations of nerve growth factor (NGF) and Prostaglandin E2 (PGE2) and its receptors were studied in bladder and urine in streptozotocin (STZ)-induced diabetic rats. Methodology/Principal Findings: Diabetes mellitus was induced with a single dose of 45 mg/kg STZ Intraperitoneally (i.p) in female Sprague-Dawley rats. Continuous cystometrogram were performed on control rats and STZ treated rats at week 4 or 12 under urethane anesthesia. Bladder was then harvested for histology, expression of EP receptors and NGF by western blotting, PGE2 levels by ELISA, and detection of apoptosis by TUNEL staining. In addition, 4-hr urine was collected from all groups for urine levels of PGE2, and NGF assay. DM induced progressive increase of bladder weight, urine production, intercontraction interval (ICI) and residual urine in a time dependent fashion. Upregulation of Prostaglandin E receptor (EP)1 and EP3 receptors and downregulation of NGF expression, increase in urine NGF and decrease levels of urine PGE2 at week 12 was observed. The decrease in ICI by intravesical instillation of PGE2 was by 51% in control rats and 31.4% in DM group at week 12. Conclusions/Significance: DM induced hyposensitive underactive bladder which is characterized by increased inflammatory reaction, apoptosis, urine NGF levels, upregulation of EP1 and EP3 receptors and decreased bladder NGF and urine PGE2. The data suggest that EP3 receptor are potential targets in the treatment of diabetes induced underactive bladder. © 2014 Nirmal et al

    Germ Line Origin and Somatic Mutations Determine the Target Tissues in Systemic AL-Amyloidosis

    Get PDF
    BACKGROUND: Amyloid is insoluble aggregated proteins deposited in the extra cellular space. About 25 different proteins are known to form amyloid in vivo and are associated with severe diseases such as Alzheimer's disease, prion diseases and type-2 diabetes. Light chain (AL) -amyloidosis is unique among amyloid diseases in that the fibril protein, a monoclonal immunoglobulin light chain, varies between individuals and that no two AL-proteins with identical primary structures have been described to date. The variability in tissue distribution of amyloid deposits is considerably larger in systemic AL-amyloidosis than in any other form of amyloidosis. The reason for this variation is believed to be based on the differences in properties of the amyloidogenic immunoglobulin light chain. However, there is presently no known relationship between the structure of an AL-protein and tissue distribution. METHODOLOGY/PRINCIPAL FINDINGS: We compared the pattern of amyloid deposition in four individuals with amyloid protein derived from variable light chain gene O18-O8, the source of a high proportion of amyloidogenic light chains, and in whom all or most of the fibril protein had been determined by amino acid sequencing. In spite of great similarities between the structures of the proteins, there was a pronounced variability in deposition pattern. We also compared the tissue distribution in these four individuals with that of four other patients with AL-amyloid derived from the L2-L16 gene. Although the interindividual variations were pronounced, liver and kidney involvement was much more evident in the latter four. CONCLUSIONS/SIGNIFICANCE: We conclude that although the use of a specific gene influences the tissue distribution of amyloid, each light chain exhibits one or more determinants of organ-specificity, which originate from somatic mutations and post-translational modifications. Eventual identification of such determinants could lead to improved treatment of patients with AL amyloidosis

    Quantum coherent control of a hybrid superconducting circuit made with graphene-based van der Waals heterostructures

    Full text link
    Quantum coherence and control is foundational to the science and engineering of quantum systems. In van der Waals (vdW) materials, the collective coherent behavior of carriers has been probed successfully by transport measurements. However, temporal coherence and control, as exemplified by manipulating a single quantum degree of freedom, remains to be verified. Here we demonstrate such coherence and control of a superconducting circuit incorporating graphene-based Josephson junctions. Furthermore, we show that this device can be operated as a voltage-tunable transmon qubit, whose spectrum reflects the electronic properties of massless Dirac fermions traveling ballistically. In addition to the potential for advancing extensible quantum computing technology, our results represent a new approach to studying vdW materials using microwave photons in coherent quantum circuits

    Amplitude Spectroscopy of a Solid-State Artificial Atom

    Get PDF
    The energy-level structure of a quantum system plays a fundamental role in determining its behavior and manifests itself in a discrete absorption and emission spectrum. Conventionally, spectra are probed via frequency spectroscopy whereby the frequency \nu of a harmonic driving field is varied to fulfill the conditions \Delta E = h \nu, where the driving field is resonant with the level separation \Delta E (h is Planck's constant). Although this technique has been successfully employed in a variety of physical systems, including natural and artificial atoms and molecules, its application is not universally straightforward, and becomes extremely challenging for frequencies in the range of 10's and 100's of gigahertz. Here we demonstrate an alternative approach, whereby a harmonic driving field sweeps the atom through its energy-level avoided crossings at a fixed frequency, surmounting many of the limitations of the conventional approach. Spectroscopic information is obtained from the amplitude dependence of the system response. The resulting ``spectroscopy diamonds'' contain interference patterns and population inversion that serve as a fingerprint of the atom's spectrum. By analyzing these features, we determine the energy spectrum of a manifold of states with energies from 0.01 to 120 GHz \times h in a superconducting artificial atom, using a driving frequency near 0.1 GHz. This approach provides a means to manipulate and characterize systems over a broad bandwidth, using only a single driving frequency that may be orders of magnitude smaller than the energy scales being probed.Comment: 12 pages, 13 figure

    Levels of DNA methylation vary at CpG sites across the BRCA1 promoter, and differ according to triple negative and "BRCA-like" status, in both blood and tumour DNA

    Get PDF
    Triple negative breast cancer is typically an aggressive and difficult to treat subtype. It is often associated with loss of function of the BRCA1 gene, either through mutation, loss of heterozygosity or methylation. This study aimed to measure methylation of the BRCA1 gene promoter at individual CpG sites in blood, tumour and normal breast tissue, to assess whether levels were correlated between different tissues, and with triple negative receptor status, histopathological scoring for BRCA-like features and BRCA1 protein expression. Blood DNA methylation levels were significantly correlated with tumour methylation at 9 of 11 CpG sites examined (p<0.0007). The levels of tumour DNA methylation were significantly higher in triple negative tumours, and in tumours with high BRCA-like histopathological scores (10 of 11 CpG sites; p<0.01 and p<0.007 respectively). Similar results were observed in blood DNA (6 of 11 CpG sites; p<0.03 and 7 of 11 CpG sites; p<0.02 respectively). This study provides insight into the pattern of CpG methylation across the BRCA1 promoter, and supports previous studies suggesting that tumours with BRCA1 promoter methylation have similar features to those with BRCA1 mutations, and therefore may be suitable for the same targeted therapies

    Quantitative determination of vitamin D metabolites in plasma using UHPLC-MS/MS

    Get PDF
    Vitamin D is an important determinant of bone health at all ages. The plasma concentrations of 25-hydroxy vitamin D (25-OH D) and other metabolites are used as biomarkers for vitamin sufficiency and function. To allow for the simultaneous determination of five vitamin D metabolites, 25-OH D3, 25-OH D2, 24,25-(OH)2 D3, 1,25-(OH)2 D3, and 1,25-(OH)2 D2, in low volumes of human plasma, an assay using ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) was established. Plasma samples were spiked with isotope-labeled internal standards and pretreated using protein precipitation, solid-phase extraction (SPE) and a Diels–Alder derivatization step with 4-phenyl-1,2,4-triazoline-3,5-dione. The SPE recovery rates ranged from 55% to 85%, depending on the vitamin D metabolite; the total sample run time was <5 min. Mass spectrometry was conducted using positive ion electrospray ionization in the multiple reaction monitoring mode on a quadrupole–quadrupole-linear ion trap instrument after pre-column addition of methylamine to increase the ionization efficiency. The intra- and inter-day relative standard deviations were 1.6–4.1% and 3.7–6.8%, respectively. The limit of quantitation for these compounds was determined to be between 10 and 20 pg/mL. The 25-OH D results were compared with values obtained for reference materials (DEQAS). In addition, plasma samples were analyzed with two additional Diasorin antibody assays. All comparisons with conventional methods showed excellent correlations (r2 = 0.9738) for DEQAS samples, demonstrating the high degree of comparability of the new UHPLC-MS/MS technique to existing methods
    corecore