25 research outputs found
Trends in pediatric epilepsy surgery in Europe between 2008 and 2015: Country‐, center‐, and age‐specific variation
OBJECTIVE: To profile European trends in pediatric epilepsy surgery (<16 years of age) between 2008 and 2015. METHODS: We collected information on volumes and types of surgery, pathology, and seizure outcome from 20 recognized epilepsy surgery reference centers in 10 European countries. RESULTS: We analyzed retrospective aggregate data on 1859 operations. The proportion of surgeries significantly increased over time (P < .0001). Engel class I outcome was achieved in 69.3% of children, with no significant improvement between 2008 and 2015. The proportion of histopathological findings consistent with glial scars significantly increased between the ages of 7 and 16 years (P for trend = .0033), whereas that of the remaining pathologies did not vary across ages. A significant increase in unilobar extratemporal surgeries (P for trend = .0047) and a significant decrease in unilobar temporal surgeries (P for trend = .0030) were observed between 2008 and 2015. Conversely, the proportion of multilobar surgeries and unrevealing magnetic resonance imaging cases remained unchanged. Invasive investigations significantly increased, especially stereo‐electroencephalography. We found different trends comparing centers starting their activity in the 1990s to those whose programs were developed in the past decade. Multivariate analysis revealed a significant variability of the proportion of the different pathologies and surgical approaches across countries, centers, and age groups between 2008 and 2015. SIGNIFICANCE: Between 2008 and 2015, we observed a significant increase in the volume of pediatric epilepsy surgeries, stability in the proportion of Engel class I outcomes, and a modest increment in complexity of the procedures
Technical Design Report for the: PANDA Micro Vertex Detector
This document illustrates the technical layout and the expected performance
of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect
charged particles as close as possible to the interaction zone. Design criteria
and the optimisation process as well as the technical solutions chosen are
discussed and the results of this process are subjected to extensive Monte
Carlo physics studies. The route towards realisation of the detector is
outlined.Comment: 189 pages, 225 figures, 41 table
The phenotypic spectrum of WWOX -related disorders: 20 additional cases of WOREE syndrome and review of the literature
Purpose: Germline WWOX pathogenic variants have been associated with disorder of sex differentiation (DSD), spinocerebellar ataxia (SCA), and WWOX-related epileptic encephalopathy (WOREE syndrome). We review clinical and molecular data on WWOX-related disorders, further describing WOREE syndrome and phenotype/genotype correlations. Methods: We report clinical and molecular findings in 20 additional patients from 18 unrelated families with WOREE syndrome and biallelic pathogenic variants in the WWOX gene. Different molecular screening approaches were used (quantitative polymerase chain reaction/multiplex ligation-dependent probe amplification [qPCR/MLPA], array comparative genomic hybridization [array-CGH], Sanger sequencing, epilepsy gene panel, exome sequencing). Results: Two copy-number variations (CNVs) or two single-nucleotide variations (SNVs) were found respectively in four and nine families, with compound heterozygosity for one SNV and one CNV in five families. Eight novel missense pathogenic variants have been described. By aggregating our patients with all cases reported in the literature, 37 patients from 27 families with WOREE syndrome are known. This review suggests WOREE syndrome is a very severe epileptic encephalopathy characterized by absence of language development and acquisition of walking, early-onset drug-resistant seizures, ophthalmological involvement, and a high likelihood of premature death. The most severe clinical presentation seems to be associated with null genotypes. Conclusion: Germline pathogenic variants in WWOX are clearly associated with a severe early-onset epileptic encephalopathy. We report here the largest cohort of individuals with WOREE syndrome
Participatory Populism: Online Discussion Forums on Mainstream News Sites During the 2014 European Parliament Election
The phenotypic spectrum of WWOX-related Epileptic Encephalopathy: 20 additional cases and review of the literature
51st Conference of the European-Society-of-Human-Genetics (ESHG) in conjunction with the European Meeting on Psychosocial Aspects of Genetics (EMPAG), Milan, ITALY, JUN 16-19, 2018International audienc
Recessive loss-of-function mutations in AP4S1 cause mild fever-sensitive seizures, developmental delay and spastic paraplegia through loss of AP-4 complex assembly
Lifetime Measurements of and Atoms to Test Low-Energy QCD Predictions
%PS212 \\ \\ The proposed experiment aims to measure the lifetime of atoms in the ground state with 10\% precision, using the 24~GeV/c proton beam of the CERN Proton Synchrotron. As the value of the above lifetime of order 10 ^- ^{1} ^{5} s is dictated by a strong interaction at low energy, the precise measurement of this quantity enables to determine a combination of S-wave pion scattering lengths to 5\%. Pion scattering lengths have been calculated in the framework of chiral perturbation theory and values predicted at the same level of accuracy have, up to now, never been confronted with accurate experimental data. Such a measurement would submit the understanding of chiral symmetry breaking of QCD to a crucial test
Current use of imaging and electromagnetic source localization procedures in epilepsy surgery centers across Europe.
OBJECTIVE: In 2014 the European Union-funded E-PILEPSY project was launched to improve awareness of, and accessibility to, epilepsy surgery across Europe. We aimed to investigate the current use of neuroimaging, electromagnetic source localization, and imaging postprocessing procedures in participating centers.
METHODS: A survey on the clinical use of imaging, electromagnetic source localization, and postprocessing methods in epilepsy surgery candidates was distributed among the 25 centers of the consortium. A descriptive analysis was performed, and results were compared to existing guidelines and recommendations.
RESULTS: Response rate was 96%. Standard epilepsy magnetic resonance imaging (MRI) protocols are acquired at 3 Tesla by 15 centers and at 1.5 Tesla by 9 centers. Three centers perform 3T MRI only if indicated. Twenty-six different MRI sequences were reported. Six centers follow all guideline-recommended MRI sequences with the proposed slice orientation and slice thickness or voxel size. Additional sequences are used by 22 centers. MRI postprocessing methods are used in 16 centers. Interictal positron emission tomography (PET) is available in 22 centers; all using 18F-fluorodeoxyglucose (FDG). Seventeen centers perform PET postprocessing. Single-photon emission computed tomography (SPECT) is used by 19 centers, of which 15 perform postprocessing. Four centers perform neither PET nor SPECT in children. Seven centers apply magnetoencephalography (MEG) source localization, and nine apply electroencephalography (EEG) source localization. Fourteen combinations of inverse methods and volume conduction models are used.
SIGNIFICANCE: We report a large variation in the presurgical diagnostic workup among epilepsy surgery centers across Europe. This diversity underscores the need for high-quality systematic reviews, evidence-based recommendations, and harmonization of available diagnostic presurgical methods
Current use of imaging and electromagnetic source localization procedures in epilepsy surgery centers across Europe.
Species diversification – which species should we use?
Large detector systems for particle and astroparticle physics; Particle tracking detectors; Gaseous detectors; Calorimeters; Cherenkov detectors; Particle identification methods; Photon detectors for UV. visible and IR photons; Detector alignment and calibration methods; Detector cooling and thermo-stabilization; Detector design and construction technologies and materials. The LHCb experiment is dedicated to precision measurements of CP violation and rare decays of B hadrons at the Large Hadron Collider (LHC) at CERN (Geneva). The initial configuration and expected performance of the detector and associated systems. as established by test beam measurements and simulation studies. is described. © 2008 IOP Publishing Ltd and SISSA