3,417 research outputs found

    Sqrt{shat}_{min} resurrected

    Full text link
    We discuss the use of the variable sqrt{shat}_{min}, which has been proposed in order to measure the hard scale of a multi parton final state event using inclusive quantities only, on a SUSY data sample for a 14 TeV LHC. In its original version, where this variable was proposed on calorimeter level, the direct correlation to the hard scattering scale does not survive when effects from soft physics are taken into account. We here show that when using reconstructed objects instead of calorimeter energy and momenta as input, we manage to actually recover this correlation for the parameter point considered here. We furthermore discuss the effect of including W + jets and t tbar+jets background in our analysis and the use of sqrt{shat}_{min} for the suppression of SM induced background in new physics searches.Comment: 23 pages, 9 figures; v2: 1 figure, several subsections and references as well as new author affiliation added. Corresponds to published versio

    Bone mineral content after renal transplantation

    Get PDF
    Forearm bone mineral content (BMC), as evaluated by photonabsorption densitometry, was measured in 28 cadaver kidney donor recipients who entered the study 8 weeks postoperatively and were followed up for 18 months. BMC decreased signifiantly (p<0.05) but marginally in placebo-treated patients (n=14) (initial BMC 1.09±0.25 g/cm; final BMC 1.05±0.24). Fourteen patients were prophylactically given 1,25(OH)2vitamin D3 in a dose which avoided hypercalcemia and hypercalciuria (sim0.25 µg/day); under 1,25(OH)2 vitamin D3 prophylaxis a significant decrease of forearm BMC was observed no longer (initial BMC 0.94±0.21 g/cm; final BMC 0.95±0.21), but the difference between placebo and 1,25(OH)2 vitamin D3 narrowly missed statistical significance (p=0.066). It is concluded that the decrease of forearm BMC is negligible in transplant recipients with low steroid regimens. The data suggest a trend for prophylaxis with 1,25(OH)2 vitamin D3 to slightly ameliorate forearm (cortical) BMC loss

    Dark Matter Spin-Dependent Limits for WIMP Interactions on 19-F by PICASSO

    Get PDF
    The PICASSO experiment at SNOLAB reports new results for spin-dependent WIMP interactions on 19^{19}F using the superheated droplet technique. A new generation of detectors and new features which enable background discrimination via the rejection of non-particle induced events are described. First results are presented for a subset of two detectors with target masses of 19^{19}F of 65 g and 69 g respectively and a total exposure of 13.75 ±\pm 0.48 kgd. No dark matter signal was found and for WIMP masses around 24 GeV/c2^2 new limits have been obtained on the spin-dependent cross section on 19^{19}F of σF\sigma_F = 13.9 pb (90% C.L.) which can be converted into cross section limits on protons and neutrons of σp\sigma_p = 0.16 pb and σn\sigma_n = 2.60 pb respectively (90% C.L). The obtained limits on protons restrict recent interpretations of the DAMA/LIBRA annual modulations in terms of spin-dependent interactions.Comment: Revised version, accepted for publication in Phys. Lett. B, 20 pages, 7 figure

    Constraints on Low-Mass WIMP Interactions on 19F from PICASSO

    Get PDF
    Recent results from the PICASSO dark matter search experiment at SNOLAB are reported. These results were obtained using a subset of 10 detectors with a total target mass of 0.72 kg of 19F and an exposure of 114 kgd. The low backgrounds in PICASSO allow recoil energy thresholds as low as 1.7 keV to be obtained which results in an increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below 10 GeV/c^2. No dark matter signal was found. Best exclusion limits in the spin dependent sector were obtained for WIMP masses of 20 GeV/c^2 with a cross section on protons of sigma_p^SD = 0.032 pb (90% C.L.). In the spin independent sector close to the low mass region of 7 GeV/c2 favoured by CoGeNT and DAMA/LIBRA, cross sections larger than sigma_p^SI = 1.41x10^-4 pb (90% C.L.) are excluded.Comment: 23 pages, 7 figures, to be published in Phys. Lett.

    Limits on spin-dependent WIMP-nucleon cross-sections from the first ZEPLIN-II data

    Get PDF
    The first underground data run of the ZEPLIN-II experiment has set a limit on the nuclear recoil rate in the two-phase xenon detector for direct dark matter searches. In this paper the results from this run are converted into the limits on spin-dependent WIMP-proton and WIMP-neutron cross-sections. The minimum of the curve for WIMP-neutron cross-section corresponds to 0.07 pb at a WIMP mass of around 65 GeV.Comment: 12 pages, 2 figures, to be published in Physics Letters

    The impact of the ATLAS zero-lepton, jets and missing momentum search on a CMSSM fit

    Full text link
    Recent ATLAS data significantly extend the exclusion limits for supersymmetric particles. We examine the impact of such data on global fits of the constrained minimal supersymmetric standard model (CMSSM) to indirect and cosmological data. We calculate the likelihood map of the ATLAS search, taking into account systematic errors on the signal and on the background. We validate our calculation against the ATLAS determinaton of 95% confidence level exclusion contours. A previous CMSSM global fit is then re-weighted by the likelihood map, which takes a bite at the high probability density region of the global fit, pushing scalar and gaugino masses up.Comment: 16 pages, 7 figures. v2 has bigger figures and fixed typos. v3 has clarified explanation of our handling of signal systematic

    The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning

    Get PDF
    We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.Comment: 25 pages, 19 figures. Submitted to Astropart. Phys. Some figures down sampled to reduce siz

    Nuclear spin structure in dark matter search: The finite momentum transfer limit

    Get PDF
    Spin-dependent elastic scattering of weakly interacting massive dark matter particles (WIMP) off nuclei is reviewed. All available, within different nuclear models, structure functions S(q) for finite momentum transfer (q>0) are presented. These functions describe the recoil energy dependence of the differential event rate due to the spin-dependent WIMP-nucleon interactions. This paper, together with the previous paper ``Nuclear spin structure in dark matter search: The zero momentum transfer limit'', completes our review of the nuclear spin structure calculations involved in the problem of direct dark matter search.Comment: 39 pages, 12 figures, a review in revtex
    corecore