88 research outputs found

    Experimental characterization and multi-physics simulation of a triple-junction cell in a novel hybrid III:V concentrator photovoltaic–thermoelectric receiver design with secondary optical element

    Get PDF
    A lattice-matched monolithic triple-junction Concentrator Photovoltaic cell (InGa(0.495)P/GaIn(0.012)As/Ge) was electrically and thermally interfaced to a Thermoelectric Peltier module. A single optical design secondary lens was bonded to the CPV-TE receiver. The hybrid SILO-CPV-TE solar energy harvesting device was electrically, thermally and theoretically investigated. The electrical performance data for the cell under variable irradiance and cell temperature conditions were measured using the integrated thermoelectric module as both a temperature sensor and as a solid-state heat pump. The cell was electrically characterised under standard test conditions (1000 W/m2 irradiance, 25°C temperature and AM1.5G spectrum) for comparison with literature data. Transient multiphysics simulations in ANSYS CFX 15.0 were carried out to calculate cell temperatures and to determine the short circuit current and temperature coefficient in a scaling law. The optimization was used to determine 15 model parameters for the component sub-cells within the triple-junction cell at STC with a MATLAB scaling law. The root-mean-square error in electrical currents between measurement and simulations was 0.66%

    Design and characterization of hybrid III–V concentrator photovoltaic–thermoelectric receivers under primary and secondary optical elements

    Get PDF
    Lattice-matched monolithic triple-junction Concentrator Photovoltaic (CPV) cells (InGa(0.495)P/GaIn(0.012)As/Ge) were electrically and thermally interfaced to two Thermoelectric (TE) Peltier module designs. An electrical and thermal model of the hybrid receivers was modelled in COMSOL Multiphysics software v5.3 to improve CPV cell cooling whilst increasing photon energy conversion efficiency. The receivers were measured for current-voltage characteristics with the CPV cell only (with sylguard encapsulant), under single secondary optical element (SOE) at x2.5 optical concentration, and under Fresnel lens primary optical element (POE) concentration between x313 and x480. Measurements were taken in solar simulators at Cardiff and Jaén Universities, and on-sun with dual-axis tracking at Jaén University. The hybrid receivers were electrically, thermally and theoretically investigated. The electrical performance data for the cells under variable irradiance and cell temperature conditions were measured using the integrated thermoelectric module as both a temperature sensor and as a solid-state heat pump. The performance of six SOE-CPV-TE hybrid devices were evaluated within two 3-receiver strings under primary optical concentration with measured acceptance angles of 1.00o and 0.89o, similar to commercially sourced CPV modules. A six-parameter one-diode equivalent electrical model was developed for the multi-junction CPV cells with SOE and POE. This was applied to extract six model parameters with the experimental I-V curves of type A receiver at 1, 3 and 500 concentration ratios. Standard test conditions (1000W/m2, 25oC and AM1.5G spectrum) were assumed based on trust-region-reflective least squares algorithm in MATLAB. The model fitted the experimental I-V curves satisfactorily with a mean error of 4.44%, and the optical intensity gain coefficient of SOE and POE is as high as 0.91, in comparison with 0.50-0.86 for crossed compound parabolic concentrators (CCPC). The determined values of diode reverse saturation current, combined series resistance and shunt resistance were similar to those of monocrystalline PV cell/modules in our previous publications. The model may be applicable to performance prediction of multi-junction CPV cells in the future

    Cardiovascular parameters on computed tomography are independently associated with in-hospital complications and outcomes in level-1 trauma patients

    Get PDF
    Background: In-hospital complications after trauma may result in prolonged stays, higher costs, and adverse functional outcomes. Among reported risk factors for complications are pre-existing cardiopulmonary comorbidities. Objective and quick evaluation of cardiovascular risk would be beneficial for risk assessment in trauma patients. Studies in non-trauma patients suggested an independent association between cardiovascular abnormalities visible on routine computed tomography (CT) imaging and outcomes. However, whether this applies to trauma patients is unknown.Purpose: To assess the association between cardiopulmonary abnormalities visible on routine CT images and the development of in-hospital complications in patients in a level-1 trauma center.Methods: All trauma patients aged 16 years or older with CT imaging of the abdomen, thorax, or spine and admitted to the UMC Utrecht in 2017 were included. Patients with an active infection upon admission or severe neurological trauma were excluded. Routine trauma CT images were analyzed for visible abnormalities: pulmonary emphysema, coronary artery calcifications, and abdominal aorta calcification severity. Drug-treated complications were scored. The discharge condition was measured on the Glasgow Outcome Scale.Results: In total, 433 patients (median age 50 years, 67% male, 89% ASA 1–2) were analyzed. Median Injury Severity Score and Glasgow Coma Scale score were 9 and 15, respectively. Seventy-six patients suffered from at least one complication, mostly pneumonia (n = 39, 9%) or delirium (n = 19, 4%). Left main coronary artery calcification was independently associated with the development of any complication (OR 3.9, 95% CI 1.7–8.9). An increasing number of calcified coronary arteries showed a trend toward an association with complications (p = 0.07) and was significantly associated with an adverse discharge condition (p = 0.02). Pulmonary emphysema and aortic calcifications were not associated with complications.Conclusion: Coronary artery calcification, visible on routine CT imaging, is independently associated with in-hospital complications and an adverse discharge condition in level-1 trauma patients. The findings of this study may help to identify trauma patients quickly and objectively at risk for complications in an early stage without performing additional diagnostics or interventions.</p

    Conceptual design and performance evaluation of a hybrid concentrating photovoltaic system in preparation for energy

    Get PDF
    Concentrating sunlight and focussing it on smaller sized solar cells increases the device's power output per unit active area. However, this process tends to increase the solar cell temperature considerably and has the potential to compromise system reliability. Adding a heat exchanger system to regulate this temperature rise, can improve the electrical performance whilst simultaneously providing an additional source of low temperature heat. In this study the performance of a low concentrator photovoltaic system with thermal (LCPV/T) extraction was conceptualised and evaluated in depth. An experimental analysis was performed using a first-generation prototype consisting of 5 units of Cross Compound Parabolic Concentrators (CCPC) connected to a heat extraction unit. A bespoke rotating table was used as experimental apparatus to effectively evaluate the optical performance of the system, as a function of its angular positions to replicate the motion of actual sun. Key design performance parameters for the LCPV/T collector are presented and discussed. This work also provides a useful technique to effectively calculate system performance, as a function of the orientation-dependant electrical characterisation parameters data. Finally, a Computational Fluid Dynamics (CFD) model was also applied to investigate the efficacy of the heat exchanger and hence estimate the overall co-generation benefit of using such optimisation techniques on realistic CPV systems. It was highlighted through these simulations that the water flow rate had the potential to be a critical power-generation optimisation criterion for LCPV-T systems. The maximum power output at normal incidence with concentrators and no water flow was found to be 78.4 mW. The system was found to perform with an average electrical efficiency ranging between 10 and 16% when evaluated at five different geographic locations. Experimental analysis of the data obtained showed an increase in power of 141% (power ratio 2.41) compared to the analogous non-concentrating counterpart. For example, in the case of London which receives an annual solar radiation of 1300 kWh/m2 the system is expected to generate 210 kWh/m2. This may reduce further to include losses due to temperature, reflectance/glazing losses, and electrical losses in cabling and inverter by up to 36% leading to an annual power output of 134 kWh/m2 of module

    A scaling law for monocrystalline PV/T modules with CCPC and comparison with triple junction PV cells

    Get PDF
    Scaling laws serve as a tool to convert the five parameters in a lumped one-diode electrical model of a photovoltaic (PV) cell/module/panel under indoor standard test conditions (STC) into the parameters under any outdoor conditions. By using the transformed parameters, a current-voltage curve can be established under any outdoor conditions to predict the PV cell/module/panel performance. A scaling law is developed for PV modules with and without crossed compound parabolic concentrator (CCPC) based on the experimental current-voltage curves of six flat monocrystalline PV modules collected from literature at variable irradiances and cell temperatures by using nonlinear least squares method. Experiments are performed to validate the model and method on a monocrystalline PV cell at various irradiances and cell temperatures. The proposed scaling law is compared with the existing one, and the former exhibits a much better accuracy when the cell temperature is higher than 40 °C. The scaling law of a triple junction flat PV cell is also compared with that of the monocrystalline cell and the CCPC effects on the scaling law are investigated with the monocrystalline PV cell. It is identified that the CCPCs impose a more significant influence on the scaling law for the monocrystalline PV cell in comparison with the triple junction PV cell. The proposed scaling law is applied to predict the electrical performance of PV/thermal modules with CCPC

    Is a chest radiograph indicated after chest tube removal in trauma patients? A systematic review

    Get PDF
    PURPOSE The aim of this systematic review was to assess the necessity of routine chest radiographs after chest tube removal in ventilated and nonventilated trauma patients. METHODS A systematic literature search was conducted in MEDLINE, Embase, CENTRAL, and CINAHL on May 15, 2020. Quality assessment was performed using the Methodological Index for Nonrandomized Studies criteria. Primary outcome measures were abnormalities on postremoval chest radiograph (e.g., recurrence of a pneumothorax, hemothorax, pleural effusion) and reintervention after chest tube removal. Secondary outcome measures were emergence of new clinical symptoms or vital signs after chest tube removal. RESULTS Fourteen studies were included, consisting of seven studies on nonventilated patients and seven studies on combined cohorts of ventilated and nonventilated patients, all together containing 1,855 patients. Nonventilated patients had abnormalities on postremoval chest radiograph in 10% (range across studies, 0-38%) of all chest tubes and 24% (range, 0-78%) of those underwent reintervention. In the studies that reported on clinical symptoms after chest tube removal, all patients who underwent reintervention also had symptoms of recurrent pathology. Combined cohorts of ventilated and nonventilated patients had abnormalities on postremoval chest radiograph in 20% (range, 6-49%) of all chest tubes and 45% (range, 8-63%) of those underwent reintervention. CONCLUSION In nonventilated patients, one in ten developed recurrent pathology after chest tube removal and almost a quarter of them underwent reintervention. In two studies that reported on clinical symptoms, all reinterventions were performed in patients with symptoms of recurrent pathology. In these two studies, omission of routine postremoval chest radiograph seemed safe. However, current literature remains insufficient to draw definitive conclusions on this matter, and future studies are needed. LEVEL OF EVIDENCE Systematic review study, level IV

    A coupled optical-thermal-electrical model to predict the performance of hybrid PV/T-CCPC roof-top systems

    Get PDF
    A crossed compound parabolic concentrator (CCPC) is applied into a photovoltaic/thermal (PV/T) hybrid solar collector, i.e. concentrating PV/T (CPV/T) collector, to develop new hybrid roof-top CPV/T systems. However, to optimise the system configuration and operational parameters as well as to predict their performances, a coupled optical, thermal and electrical model is essential. We establish this model by integrating a number of submodels sourced from literature as well as from our recent work on incidence-dependent optical efficiency, six-parameter electrical model and scaling law for outdoor conditions. With the model, electrical performance and cell temperature are predicted on specific days for the roof-top systems installed in Glasgow, Penryn and Jaen. Results obtained by the proposed model reasonably agree with monitored data and it is also clarified that the systems operate under off-optimal operating condition. Long-term electric performance of the CPV/T systems is estimated as well. In addition, effects of transient terms in heat transfer and diffuse solar irradiance on electric energy are identified and discussed

    Magnetic Reconnection in Extreme Astrophysical Environments

    Full text link
    Magnetic reconnection is a basic plasma process of dramatic rearrangement of magnetic topology, often leading to a violent release of magnetic energy. It is important in magnetic fusion and in space and solar physics --- areas that have so far provided the context for most of reconnection research. Importantly, these environments consist just of electrons and ions and the dissipated energy always stays with the plasma. In contrast, in this paper I introduce a new direction of research, motivated by several important problems in high-energy astrophysics --- reconnection in high energy density (HED) radiative plasmas, where radiation pressure and radiative cooling become dominant factors in the pressure and energy balance. I identify the key processes distinguishing HED reconnection: special-relativistic effects; radiative effects (radiative cooling, radiation pressure, and Compton resistivity); and, at the most extreme end, QED effects, including pair creation. I then discuss the main astrophysical applications --- situations with magnetar-strength fields (exceeding the quantum critical field of about 4 x 10^13 G): giant SGR flares and magnetically-powered central engines and jets of GRBs. Here, magnetic energy density is so high that its dissipation heats the plasma to MeV temperatures. Electron-positron pairs are then copiously produced, making the reconnection layer highly collisional and dressing it in a thick pair coat that traps radiation. The pressure is dominated by radiation and pairs. Yet, radiation diffusion across the layer may be faster than the global Alfv\'en transit time; then, radiative cooling governs the thermodynamics and reconnection becomes a radiative transfer problem, greatly affected by the ultra-strong magnetic field. This overall picture is very different from our traditional picture of reconnection and thus represents a new frontier in reconnection research.Comment: Accepted to Space Science Reviews (special issue on magnetic reconnection). Article is based on an invited review talk at the Yosemite-2010 Workshop on Magnetic Reconnection (Yosemite NP, CA, USA; February 8-12, 2010). 30 pages, no figure

    The SAMI Galaxy Survey: Spatially resolving the environmental quenching of star formation in GAMA galaxies

    Get PDF
    We use data from the Sydney-AAO Multi-Object Integral Field Spectrograph (SAMI) Galaxy Survey and the Galaxy And Mass Assembly (GAMA) survey to investigate the spatially-resolved signatures of the environmental quenching of star formation in galaxies. Using dust-corrected measurements of the distribution of Hα emission we measure the radial profiles of star formation in a sample of 201 star-forming galaxies covering three orders of magnitude in stellar mass (M∗M∗; 108.1-1010.95 M⊙) and in 5th nearest neighbour local environment density (Σ5; 10−1.3- 102.1 Mpc−2). We show that star formation rate gradients in galaxies are steeper in dense (log10(Σ5/Mpc2) > 0.5) environments by 0.58 ± 0.29 dex re−1 in galaxies with stellar masses in the range 1010 1.0). These lines of evidence strongly suggest that with increasing local environment density the star formation in galaxies is suppressed, and that this starts in their outskirts such that quenching occurs in an outside-in fashion in dense environments and is not instantaneous

    State of the climate in 2013

    Get PDF
    In 2013, the vast majority of the monitored climate variables reported here maintained trends established in recent decades. ENSO was in a neutral state during the entire year, remaining mostly on the cool side of neutral with modest impacts on regional weather patterns around the world. This follows several years dominated by the effects of either La Niña or El Niño events. According to several independent analyses, 2013 was again among the 10 warmest years on record at the global scale, both at the Earths surface and through the troposphere. Some regions in the Southern Hemisphere had record or near-record high temperatures for the year. Australia observed its hottest year on record, while Argentina and New Zealand reported their second and third hottest years, respectively. In Antarctica, Amundsen-Scott South Pole Station reported its highest annual temperature since records began in 1957. At the opposite pole, the Arctic observed its seventh warmest year since records began in the early 20th century. At 20-m depth, record high temperatures were measured at some permafrost stations on the North Slope of Alaska and in the Brooks Range. In the Northern Hemisphere extratropics, anomalous meridional atmospheric circulation occurred throughout much of the year, leading to marked regional extremes of both temperature and precipitation. Cold temperature anomalies during winter across Eurasia were followed by warm spring temperature anomalies, which were linked to a new record low Eurasian snow cover extent in May. Minimum sea ice extent in the Arctic was the sixth lowest since satellite observations began in 1979. Including 2013, all seven lowest extents on record have occurred in the past seven years. Antarctica, on the other hand, had above-average sea ice extent throughout 2013, with 116 days of new daily high extent records, including a new daily maximum sea ice area of 19.57 million km2 reached on 1 October. ENSO-neutral conditions in the eastern central Pacific Ocean and a negative Pacific decadal oscillation pattern in the North Pacific had the largest impacts on the global sea surface temperature in 2013. The North Pacific reached a historic high temperature in 2013 and on balance the globally-averaged sea surface temperature was among the 10 highest on record. Overall, the salt content in nearsurface ocean waters increased while in intermediate waters it decreased. Global mean sea level continued to rise during 2013, on pace with a trend of 3.2 mm yr-1 over the past two decades. A portion of this trend (0.5 mm yr-1) has been attributed to natural variability associated with the Pacific decadal oscillation as well as to ongoing contributions from the melting of glaciers and ice sheets and ocean warming. Global tropical cyclone frequency during 2013 was slightly above average with a total of 94 storms, although the North Atlantic Basin had its quietest hurricane season since 1994. In the Western North Pacific Basin, Super Typhoon Haiyan, the deadliest tropical cyclone of 2013, had 1-minute sustained winds estimated to be 170 kt (87.5 m s-1) on 7 November, the highest wind speed ever assigned to a tropical cyclone. High storm surge was also associated with Haiyan as it made landfall over the central Philippines, an area where sea level is currently at historic highs, increasing by 200 mm since 1970. In the atmosphere, carbon dioxide, methane, and nitrous oxide all continued to increase in 2013. As in previous years, each of these major greenhouse gases once again reached historic high concentrations. In the Arctic, carbon dioxide and methane increased at the same rate as the global increase. These increases are likely due to export from lower latitudes rather than a consequence of increases in Arctic sources, such as thawing permafrost. At Mauna Loa, Hawaii, for the first time since measurements began in 1958, the daily average mixing ratio of carbon dioxide exceeded 400 ppm on 9 May. The state of these variables, along with dozens of others, and the 2013 climate conditions of regions around the world are discussed in further detail in this 24th edition of the State of the Climate series. © 2014, American Meteorological Society. All rights reserved
    • …
    corecore