9 research outputs found

    Immediate Cementless Hemiarthroplasty for Severe Destructive Glenohumeral Tuberculous Arthritis

    Get PDF
    The glenohumeral joint tuberculosis (TB) is rare as compared with other joints. Plaster immobilization, arthrodesis, and resection arthroplasty have been proposed as the additional treatments with anti-TB medications in severe destructive arthritis. To our knowledge, however, the surgical treatment with shoulder arthroplasty has never been reported. We present two cases of active TB with unsalvageable glenohumeral joint. The cementless hemishoulder arthroplasties were performed immediately following the radical debridement. Anti-TB medications were given for 12 months after the surgery. Postoperatively, the patients were satisfied with the rapid symptomatic relief and significant functional recovery. With the follow-up period of 5 years, the operative results were still satisfactory and the reactivation of the infection was not detected

    Radial head replacement with the 3D-printed patient-specific titanium prosthesis: Preliminary results of a multi-centric prospective study

    No full text
    Purpose To report preliminary clinical results and safety of 3D-printed patient-specific titanium radial head (RH) prosthesis in treatment of the irreparable RH fractures. Material and methods This multi-centric prospective study included 10 patients (6 men and four women, mean age 41 years (range, 25–64 years)). Three cases were classified as Mason type III and 7 cases as type IV. Patients were assessed preoperatively, intraoperatively, and at 1, 6, 12, 24, 36, and 48 weeks postoperatively. Range of motion (ROM), visual analog scale (VAS) score, Disabilities of the Arm, Shoulder and Hand (DASH) score, Mayo Elbow Performance Score (MEPS), radiology imaging, and laboratory blood and urine testing were evaluated. Results The prostheses were implanted utilizing cemented stems in 5 patients and cementless stems in 5 patients. Intraoperatively, well congruency of a prosthesis with capitellum and radial notch of ulna was observed in all cases. All patients had improvement of ROM, VAS score, DASH score, and MEPS during the postoperative follow-ups. At the final follow-up, mean elbow extension was 6.5° (range, 0°–30°), flexion 145° (range, 125°–150°), supination 79° (range, 70°–80°), and pronation 73.5° (range, 45°–80°). Mean VAS score was 0.3 (range, 0–3), DASH score was 12.35 (range, 1.7–23.3), and MEPS was 99.5 (range, 95–100). Postoperative radiographs demonstrated heterotopic ossification in 2 cases, periprosthetic radiolucency in 2 cases, and proximal radial neck resorption in 2 cases. No one had the evidence of capitellar erosion, implant failure, malpositioning, overstuffing, or symptomatic stem loosening. There was no significant alteration of laboratory results or adverse events related to the 3D-printed prosthesis implantation. Conclusion The preliminary results demonstrated that implantation of the 3D-printed patient-specific titanium RH prosthesis is safe and may be a potential treatment option for irreparable RH fracture

    The Patient-Specific Implant Created with 3D Printing Technology in Treatment of the Irreparable Radial Head in Chronic Persistent Elbow Instability

    No full text
    Successful treatment of the chronic persistent elbow instability is a challenge for orthopedic surgeons. In this form, it is important to recognize and restore the osseous stabilizer in order to obtain the concentric reduction. In the present report, we describe a case of such injury with irreparable radial head treated with patient-specific radial head prosthesis which was created with 3D printing technology. To our knowledge, this is the first report in clinical use of this kind of prosthesis for the radial head fracture. At a 24-month follow-up visit, the patient was satisfied with the functional outcomes. The Mayo Elbow Performance Index (MEPI) increased from 20 points at the preoperative day to 85 points, and the patient-based Disabilities of the Arm, Shoulder, and Hand (DASH) was reduced from 88.33 points to 28.33 points. Due to the favorable result, replacement of the radial head with the patient-specific implant could be a useful treatment for the irreparable radial head in chronic persistent elbow instability

    A Patient-Matched Entire First Metacarpal Prosthesis in Treatment of Giant Cell Tumor of Bone

    No full text
    Giant cell tumor of the bones occurring in the first metacarpals frequently requires entire metacarpal resection due to the aggressive nature and high rate of recurrence. Bone reconstruction can be performed with autogenous bone grafts. Here we describe a new technique of reconstruction using a patient-matched three-dimensional printed titanium first metacarpal prosthesis. This prosthesis has a special design for ligament reconstruction in the proximal and distal portions. Good hand function and aesthetic appearance were maintained at a 24-month follow-up visit. This reconstructive technique can avoid donor-site complications and spare the autogenous bone grafts for revision options
    corecore