162 research outputs found

    Time to reduce CD4+ monitoring for the management of antiretroviral therapy in HIV-infected individuals

    Get PDF
    Access to antiretroviral therapy (ART) is expanding at a rapid rate in resource-limited settings, with ambitious goals such as having 90% of infected individuals on ART by 2020. With the expansion of ART, there will be the need to expand assays for both HIV diagnosis and monitoring. To achieve these goals, clinical and diagnostic algorithms need to undergo constant review to ensure that they remain relevant and have the desired impact. While all assays used in HIV care need to be considered, this opinion focuses on the changes that could be made to CD4+ testing algorithms, resulting in reduced use allowing funds to be diverted to the current gold standard assay for measuring treatment success, the HIV viral load.

    How South Africa Used National Cycle Threshold (Ct) Values to Continuously Monitor SARS-CoV-2 Laboratory Test Quality

    Get PDF
    The high demand for SARS-CoV-2 tests but limited supply to South African laboratories early in the COVID-19 pandemic resulted in a heterogenous diagnostic footprint of open and closed molecular testing platforms being implemented. Ongoing monitoring of the performance of these multiple and varied systems required novel approaches, especially during the circulation of variants. The National Health Laboratory Service centrally collected cycle threshold (Ct) values from 1,497,669 test results reported from 6 commonly used PCR assays in 36 months, and visually monitored changes in their median Ct within a 28-day centered moving average for each assays’ gene targets. This continuous quality monitoring rapidly identified delayed hybridization of in the Allplex & trade; SARS-CoV-2 assay due to the Delta (B.1.617.2) variant; gene target failure in the TaqPath & trade; COVID-19 assay due to B.1.1.7 (Alpha) and the B.1.1.529 (Omicron); and recently gene delayed hybridization in the Xpress SARS-CoV-2 due to XBB.1.5. This near ;real-time; monitoring helped inform the need for sequencing and the importance of multiplex molecular nucleic acid amplification technology designs used in diagnostics for patient care. This continuous quality monitoring approach at the granularity of Ct values should be included in ongoing surveillance and with application to other disease use cases that rely on molecular diagnostics

    HIV-1 viral load assays for resource-limited settings: Authors' reply [5]

    Get PDF
    The authors discuss studies on the low-cost viral load assays that are currently available and their potential for use in resource-limited settings

    Systematic review of the performance of HIV viral load technologies on plasma samples.

    Get PDF
    BACKGROUND: Viral load (VL) monitoring is the standard of care in developing country settings for detecting HIV treatment failure. Since 2010 the World Health Organization has recommended a phase-in approach to VL monitoring in resource-limited settings. We conducted a systematic review of the accuracy and precision of HIV VL technologies for treatment monitoring. METHODS AND FINDINGS: A search of Medline and Embase was conducted for studies evaluating the accuracy or reproducibility of commercially available HIV VL assays. 37 studies were included for review including evaluations of the Amplicor Monitor HIV-1 v1.5 (n = 25), Cobas TaqMan v2.0 (n = 11), Abbott RealTime HIV-1 (n = 23), Versant HIV-1 RNA bDNA 3.0 (n = 15), Versant HIV-1 RNA kPCR 1.0 (n = 2), ExaVir Load v3 (n = 2), and NucliSens EasyQ v2.0 (n = 1). All currently available HIV VL assays are of sufficient sensitivity to detect plasma virus levels at a lower detection limit of 1,000 copies/mL. Bias data comparing the Abbott RealTime HIV-1, TaqMan v2.0 to the Amplicor Monitor v1.5 showed a tendency of the Abbott RealTime HIV-1 to under-estimate results while the TaqMan v2.0 overestimated VL counts. Compared to the Amplicor Monitor v1.5, 2-26% and 9-70% of results from the Versant bDNA 3.0 and Abbott RealTime HIV-1 differed by greater than 0.5log10. The average intra and inter-assay variation of the Abbott RealTime HIV-1 were 2.95% (range 2.0-5.1%) and 5.44% (range 1.17-30.00%) across the range of VL counts (2log10-7log10). CONCLUSIONS: This review found that all currently available HIV VL assays are of sufficient sensitivity to detect plasma VL of 1,000 copies/mL as a threshold to initiate investigations of treatment adherence or possible treatment failure. Sources of variability between VL assays include differences in technology platform, plasma input volume, and ability to detect HIV-1 subtypes. Monitoring of individual patients should be performed on the same technology platform to ensure appropriate interpretation of changes in VL. Prospero registration # CD42013003603

    A comparison of the predictive accuracy of three screening models for pulmonary arterial hypertension in systemic sclerosis

    Get PDF
    Introduction: There is evidence that early screening for pulmonary arterial hypertension (PAH) in systemic sclerosis (SSc) improves outcomes. We compared the predictive accuracy of two recently published screening algorithms (DETECT 2013 and Australian Scleroderma Interest Group (ASIG) 2012) for SSc-associated PAH (SSc-PAH) with the commonly used European Society of Cardiology/European Respiratory Society (ESC/ERS 2009) guidelines. Methods: We included 73 consecutive SSc patients with suspected PAH undergoing right heart catheterization (RHC). The three screening models were applied to each patient. For each model, contingency table analysis was used to determine sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values for PAH. These properties were also evaluated in an ‘alternate scenario analysis’ in which the prevalence of PAH was set at 10%. Results: RHC revealed PAH in 27 (36.9%) patients. DETECT and ASIG algorithms performed equally in predicting PAH with sensitivity and NPV of 100%. The ESC/ERS guidelines had sensitivity of 96.3% and NPV of only 91%, missing one case of PAH; these guidelines could not be applied to three patients who had absent tricuspid regurgitant (TR) jet. The ASIG algorithm had the highest specificity (54.5%). With PAH prevalence set at 10%, the NPV of the models was unchanged, but the PPV dropped to less than 20%. Conclusions: In this cohort, the DETECT and ASIG algorithms out-perform the ESC/ERS guidelines, detecting all patients with PAH. The ESC/ERS guidelines have limitations in the absence of a TR jet. Ultimately, the choice of SSc-PAH screening algorithm will also depend on cost and ease of application

    Systematic review of the use of dried blood spots for monitoring HIV viral load and for early infant diagnosis.

    Get PDF
    BACKGROUND: Dried blood spots (DBS) have been used as alternative specimens to plasma to increase access to HIV viral load (VL) monitoring and early infant diagnosis (EID) in remote settings. We systematically reviewed evidence on the performance of DBS compared to plasma for VL monitoring and EID. METHODS AND FINDINGS: Thirteen peer reviewed HIV VL publications and five HIV EID papers were included. Depending on the technology and the viral load distribution in the study population, the percentage of DBS samples that are within 0.5 log of VL in plasma ranged from 52-100%. Because the input sample volume is much smaller in a blood spot, there is a risk of false negatives with DBS. Sensitivity of DBS VL was found to be 78-100% compared to plasma at VL below 1000 copies/ml, but this increased to 100% at a threshold of 5000 copies/ml. Unlike a plasma VL test which measures only cell free HIV RNA, a DBS VL also measures proviral DNA as well as cell-associated RNA, potentially leading to false positive results when using DBS. The systematic review showed that specificity was close to 100% at DBS VL above 5000 copies/ml, and this threshold would be the most reliable for predicting true virologic failure using DBS. For early infant diagnosis, DBS has a sensitivity of 100% compared to fresh whole blood or plasma in all studies. CONCLUSIONS: Although limited data are available for EID, DBS offer a highly sensitive and specific sampling strategy to make viral load monitoring and early infant diagnosis more accessible in remote settings. A standardized approach for sampling, storing, and processing DBS samples would be essential to allow successful implementation. TRIAL REGISTRATION: PROSPERO Registration #: CRD42013003621

    Observational study on variability between biobanks in the estimation of DNA concentration.

    Get PDF
    BACKGROUND: There is little confidence in the consistency of estimation of DNA concentrations when samples move between laboratories. Evidence on this consistency is largely anecdotal. Therefore there is a need first to measure this consistency among different laboratories and then identify and implement remedies. A pilot experiment to test logistics and provide initial data on consistency was therefore conceived. METHODS: DNA aliquots at nominal concentrations between 10 and 300 ng/mul were dispensed into the wells of 96-well plates by one participant - the coordinating centre. Participants estimated the concentration in each well and returned estimates to the coordinating centre. RESULTS: Considerable overall variability was observed among estimates. There were statistically significant differences between participants' measurements and between fluorescence emission and absorption spectroscopy. CONCLUSION: Anecdotal evidence of variability in DNA concentration estimation has been substantiated. Reduction in variability between participants will require the identification of major sources of variation, specification of effective remedies and their implementation

    Clinical Research and Development of Tuberculosis Diagnostics: Moving From Silos to Synergy

    Get PDF
    The development, evaluation, and implementation of new and improved diagnostics have been identified as critical needs by human immunodeficiency virus (HIV) and tuberculosis researchers and clinicians alike. These needs exist in international and domestic settings and in adult and pediatric populations. Experts in tuberculosis and HIV care, researchers, healthcare providers, public health experts, and industry representatives, as well as representatives of pertinent US federal agencies (Centers for Disease Control and Prevention, Food and Drug Administration, National Institutes of Health, United States Agency for International Development) assembled at a workshop proposed by the Diagnostics Working Group of the Federal Tuberculosis Taskforce to review the state of tuberculosis diagnostics development in adult and pediatric populations

    The inclusion of N-terminal pro-brain natriuretic peptide in a sensitive screening strategy for systemic sclerosis-related pulmonary arterial hypertension: a cohort study

    Get PDF
    INTRODUCTION: Pulmonary arterial hypertension (PAH) is a major cause of mortality in systemic sclerosis (SSc). Screening guidelines for PAH recommend multiple investigations, including annual echocardiography, which together have low specificity and may not be cost-effective. We sought to evaluate the predictive accuracy of serum N-terminal pro-brain natriuretic peptide (NT-proBNP) in combination with pulmonary function tests (PFT) (‘proposed’ algorithm) in a screening algorithm for SSc-PAH. METHODS: We evaluated our proposed algorithm (PFT with NT-proBNP) on 49 consecutive SSc patients with suspected pulmonary hypertension undergoing right heart catherisation (RHC). The predictive accuracy of the proposed algorithm was compared with existing screening recommendations, and is presented as sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). RESULTS: Overall, 27 patients were found to have pulmonary hypertension (PH) at RHC, while 22 had no PH. The sensitivity, specificity, PPV and NPV of the proposed algorithm for PAH was 94.1%, 54.5%, 61.5% and 92.3%, respectively; current European Society of Cardiology (ESC)/European Respiratory Society (ERS) guidelines achieved a sensitivity, specificity, PPV and NPV of 94.1%, 31.8%, 51.6% and 87.5%, respectively. In an alternate case scenario analysis, estimating a PAH prevalence of 10%, the proposed algorithm achieved a sensitivity, specificity, PPV and NPV for PAH of 94.1%, 54.5%, 18.7% and 98.8%, respectively. CONCLUSIONS: The combination of NT-proBNP with PFT is a sensitive, yet simple and non-invasive, screening strategy for SSc-PAH. Patients with a positive screening result can be referred for echocardiography, and further confirmatory testing for PAH. In this way, it may be possible to shift the burden of routine screening away from echocardiography. The findings of this study should be confirmed in larger studies
    • …