132 research outputs found

    Ultrafast element-resolved magneto-optics using a fiber-laser-driven extreme ultraviolet light source

    Full text link
    We present a novel setup to measure the transverse magneto-optical Kerr effect in the extreme ultraviolet spectral range at exceptionally high repetition rates based on a fiber laser amplifier system. This affords a very high and stable flux of extreme ultraviolet light, which we use to measure element-resolved demagnetization dynamics with unprecedented depth of information. Furthermore, the setup is equipped with a strong electromagnet and a cryostat, allowing measurements between 10 and 420 K using magnetic fields up to 0.86 T. The performance of our setup is demonstrated by a set of temperature- and time-dependent magnetization measurements showing distinct element-dependent behavior

    Profound influence of different methods for determination of the ankle brachial index on the prevalence estimate of peripheral arterial disease

    Get PDF
    BACKGROUND: The ankle brachial index (ABI) is an efficient tool for objectively documenting the presence of lower extremity peripheral arterial disease (PAD). However, different methods exist for ABI calculation, which might result in varying PAD prevalence estimates. To address this question, we compared five different methods of ABI calculation using Doppler ultrasound in 6,880 consecutive, unselected primary care patients ≥65 years in the observational getABI study. METHODS: In all calculations, the average systolic pressure of the right and left brachial artery was used as the denominator (however, in case of discrepancies of ≥10 mmHg, the higher reading was used). As nominators, the following pressures were used: the highest arterial ankle pressure of each leg (method #1), the lowest pressure (#2), only the systolic pressure of the tibial posterior artery (#3), only the systolic pressure of the tibial anterior artery (#4), and the systolic pressure of the tibial posterior artery after exercise (#5). An ABI < 0.9 was regarded as evidence of PAD. RESULTS: The estimated prevalence of PAD was lowest using method #1 (18.0%) and highest using method #2 (34.5%), while the differences in methods #3–#5 were less pronounced. Method #1 resulted in the most accurate estimation of PAD prevalence in the general population. Using the different approaches, the odds ratio for the association of PAD and cardiovascular (CV) events varied between 1.7 and 2.2. CONCLUSION: The data demonstrate that different methods for ABI determination clearly affect the estimation of PAD prevalence, but not substantially the strength of the associations between PAD and CV events. Nonetheless, to achieve improved comparability among different studies, one mode of calculation should be universally applied, preferentially method #1

    MicroRNAs in Renal Cell Carcinoma: Diagnostic Implications of Serum miR-1233 Levels

    Get PDF
    BACKGROUND: MicroRNA expression is altered in cancer cells, and microRNAs could serve as diagnostic/prognostic biomarker for cancer patients. Our study was designed to analyze circulating serum microRNAs in patients with renal cell carcinoma (RCC). METHODOLOGY/PRINCIPAL FINDINGS: We first explored microrna expression profiles in tissue and serum using taqman low density arrays in each six malignant and benign samples: Although 109 microRNAs were circulating at higher levels in cancer patients' serum, we identified only 36 microRNAs with up-regulation in RCC tissue and serum of RCC patients. Seven candidate microRNAs were selected for verification based on the finding of up-regulation in serum and tissue of RCC patients: miR-7-1*, miR-93, miR-106b*, miR-210, miR-320b, miR-1233 and miR-1290 levels in serum of healthy controls (n = 30) and RCC (n = 33) patients were determined using quantitative real-time PCR (TaqMan MicroRNA Assays). miR-1233 was increased in RCC patients, and thus validated in a multicentre cohort of 84 RCC patients and 93 healthy controls using quantitative real-time PCR (sensitivity 77.4%, specificity 37.6%, AUC 0.588). We also studied 13 samples of patients with angiomyolipoma or oncocytoma, whose serum miR-1233 levels were similar to RCC patients. Circulating microRNAs were not correlated with clinical-pathological parameters. CONCLUSIONS/SIGNIFICANCE: MicroRNA levels are distinctly increased in cancer patients, although only a small subset of circulating microRNAs has a tumor-specific origin. We identify circulating miR-1233 as a potential biomarker for RCC patients. Larger-scaled studies are warranted to fully explore the role of circulating microRNAs in RCC

    Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF

    Full text link
    The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described

    Time projection chambers for the T2K near detectors

    Get PDF
    The T2K experiment is designed to study neutrino oscillation properties by directing a high intensity neutrino beam produced at J-PARC in Tokai, Japan, towards the large Super-Kamiokande detector located 295 km away, in Kamioka, Japan. The experiment includes a sophisticated near detector complex, 280 m downstream of the neutrino production target in order to measure the properties of the neutrino beam and to better understand neutrino interactions at the energy scale below a few GeV. A key element of the near detectors is the ND280 tracker, consisting of two active scintillator-bar target systems surrounded by three large time projection chambers (TPCs) for charged particle tracking. The data collected with the tracker is used to study charged current neutrino interaction rates and kinematics prior to oscillation, in order to reduce uncertainties in the oscillation measurements by the far detector. The tracker is surrounded by the former UA1/Nomad dipole magnet and the TPCs measure the charges, momenta, and particle types of charged particles passing through them. Novel features of the TPC design include its rectangular box layout constructed from composite panels, the use of bulk micromegas detectors for gas amplification, electronics readout based on a new ASIC, and a photoelectron calibration system. This paper describes the design and construction of the TPCs, the micromegas modules, the readout electronics, the gas handling system, and shows the performance of the TPCs as deduced from measurements with particle beams, cosmic rays, and the calibration system

    Measurement of neutrino and antineutrino neutral-current quasielasticlike interactions on oxygen by detecting nuclear deexcitation γ rays

    Get PDF
    Neutrino- and antineutrino-oxygen neutral-current quasielastic-like interactions are measured at Super-Kamiokande using nuclear de-excitation γ\gamma-rays to identify signal-like interactions in data from a $14.94 \ (16.35)\times 10^{20}protonsontargetexposureoftheT2Kneutrino(antineutrino)beam.Themeasuredfluxaveragedcrosssectionsonoxygennucleiare protons-on-target exposure of the T2K neutrino (antineutrino) beam. The measured flux-averaged cross sections on oxygen nuclei are \langle \sigma_{\nu {\rm -NCQE}} \rangle = 1.70 \pm 0.17 ({\rm stat.}) ^{+ {\rm 0.51}}_{- {\rm 0.38}} ({\rm syst.}) \times 10^{-38} \ {\rm cm^2/oxygen}withafluxaveragedenergyof0.82GeVand with a flux-averaged energy of 0.82 GeV and \langle \sigma_{\bar{\nu} {\rm -NCQE}} \rangle = 0.98 \pm 0.16 ({\rm stat.}) ^{+ {\rm 0.26}}_{- {\rm 0.19}} ({\rm syst.}) \times 10^{-38} \ {\rm cm^2/oxygen}$ with a flux-averaged energy of 0.68 GeV, for neutrinos and antineutrinos, respectively. These results are the most precise to date, and the antineutrino result is the first cross section measurement of this channel. They are compared with various theoretical predictions. The impact on evaluation of backgrounds to searches for supernova relic neutrinos at present and future water Cherenkov detectors is also discussed

    Multi-messenger searches via IceCube’s high-energy neutrinos and gravitational-wave detections of LIGO/Virgo

    Get PDF
    We summarize initial results for high-energy neutrino counterpart searches coinciding with gravitational-wave events in LIGO/Virgo\u27s GWTC-2 catalog using IceCube\u27s neutrino triggers. We did not find any statistically significant high-energy neutrino counterpart and derived upper limits on the time-integrated neutrino emission on Earth as well as the isotropic equivalent energy emitted in high-energy neutrinos for each event

    In-situ estimation of ice crystal properties at the South Pole using LED calibration data from the IceCube Neutrino Observatory

    Get PDF
    The IceCube Neutrino Observatory instruments about 1 km3 of deep, glacial ice at the geographic South Pole using 5160 photomultipliers to detect Cherenkov light emitted by charged relativistic particles. A unexpected light propagation effect observed by the experiment is an anisotropic attenuation, which is aligned with the local flow direction of the ice. Birefringent light propagation has been examined as a possible explanation for this effect. The predictions of a first-principles birefringence model developed for this purpose, in particular curved light trajectories resulting from asymmetric diffusion, provide a qualitatively good match to the main features of the data. This in turn allows us to deduce ice crystal properties. Since the wavelength of the detected light is short compared to the crystal size, these crystal properties do not only include the crystal orientation fabric, but also the average crystal size and shape, as a function of depth. By adding small empirical corrections to this first-principles model, a quantitatively accurate description of the optical properties of the IceCube glacial ice is obtained. In this paper, we present the experimental signature of ice optical anisotropy observed in IceCube LED calibration data, the theory and parametrization of the birefringence effect, the fitting procedures of these parameterizations to experimental data as well as the inferred crystal properties.</p

    In situ estimation of ice crystal properties at the South Pole using LED calibration data from the IceCube Neutrino Observatory

    Get PDF
    The IceCube Neutrino Observatory instruments about 1 km3 of deep, glacial ice at the geographic South Pole. It uses 5160 photomultipliers to detect Cherenkov light emitted by charged relativistic particles. An unexpected light propagation effect observed by the experiment is an anisotropic attenuation, which is aligned with the local flow direction of the ice. We examine birefringent light propagation through the polycrystalline ice microstructure as a possible explanation for this effect. The predictions of a first-principles model developed for this purpose, in particular curved light trajectories resulting from asymmetric diffusion, provide a qualitatively good match to the main features of the data. This in turn allows us to deduce ice crystal properties. Since the wavelength of the detected light is short compared to the crystal size, these crystal properties include not only the crystal orientation fabric, but also the average crystal size and shape, as a function of depth. By adding small empirical corrections to this first-principles model, a quantitatively accurate description of the optical properties of the IceCube glacial ice is obtained. In this paper, we present the experimental signature of ice optical anisotropy observed in IceCube light-emitting diode (LED) calibration data, the theory and parameterization of the birefringence effect, the fitting procedures of these parameterizations to experimental data, and the inferred crystal properties.Peer Reviewe

    Simulation and sensitivities for a phased IceCube-Gen2 deployment

    Get PDF
    corecore