1,566 research outputs found
Performance of the EUDET-type beam telescopes
Test beam measurements at the test beam facilities of DESY have been
conducted to characterise the performance of the EUDET-type beam telescopes
originally developed within the EUDET project. The beam telescopes are equipped
with six sensor planes using MIMOSA26 monolithic active pixel devices. A
programmable Trigger Logic Unit provides trigger logic and time stamp
information on particle passage. Both data acquisition framework and offline
reconstruction software packages are available. User devices are easily
integrable into the data acquisition framework via predefined interfaces.
The biased residual distribution is studied as a function of the beam energy,
plane spacing and sensor threshold. Its standard deviation at the two centre
pixel planes using all six planes for tracking in a 6\,GeV
electron/positron-beam is measured to be
(2.88\,\pm\,0.08)\,\upmu\meter.Iterative track fits using the formalism of
General Broken Lines are performed to estimate the intrinsic resolution of the
individual pixel planes. The mean intrinsic resolution over the six sensors
used is found to be (3.24\,\pm\,0.09)\,\upmu\meter.With a 5\,GeV
electron/positron beam, the track resolution halfway between the two inner
pixel planes using an equidistant plane spacing of 20\,mm is estimated to
(1.83\,\pm\,0.03)\,\upmu\meter assuming the measured intrinsic resolution.
Towards lower beam energies the track resolution deteriorates due to increasing
multiple scattering. Threshold studies show an optimal working point of the
MIMOSA26 sensors at a sensor threshold of between five and six times their RMS
noise. Measurements at different plane spacings are used to calibrate the
amount of multiple scattering in the material traversed and allow for
corrections to the predicted angular scattering for electron beams
Combining TCAD and Monte Carlo methods to simulate CMOS pixel sensors with a small collection electrode using the Allpix framework
Combining electrostatic field simulations with Monte Carlo methods enables realistic modeling of the detector response for novel monolithic silicon detectors with strongly non-linear electric fields. Both the precise field description and the inclusion of Landau fluctuations and production of secondary particles in the sensor are crucial ingredients for the understanding and reproduction of detector characteristics.
In this paper, a CMOS pixel sensor with small collection electrode design, implemented in a high-resistivity epitaxial layer, is simulated by integrating a detailed electric field model from finite element TCAD into a Monte Carlo based simulation with the framework. The simulation results are compared to data recorded in test-beam measurements and very good agreement is found for various quantities such as cluster size, spatial resolution and efficiency. Furthermore, the observables are studied as a function of the intra-pixel incidence position to enable a detailed comparison with the detector behavior observed in data.
The validation of such simulations is fundamental for modeling the detector response and for predicting the performance of future prototype designs. Moreover, visualization plots extracted from the charge carrier drift model of the framework can aid in understanding the charge propagation behavior in different regions of the sensor
Time resolution studies of Timepix3 assemblies with thin silicon pixel sensors
Timepix3 is a multi-purpose readout ASIC for hybrid pixel detectors. It can measure time and amplitude simultaneously by employing time-of-arrival (ToA) and time-over-threshold (ToT) techniques. Both methods are systematically affected by timewalk. In this paper, a method for pixel-by-pixel calibration of the time response is presented. Assemblies of Timepix3 ASICs bump-bonded to thin planar silicon pixel sensors with thicknesses of 50 μ m, 100 μ m and 150 μ m are calibrated and characterised in particle beams. For minimum ionising particles, time resolutions down to 0.72 ± 0.04 ns are achieved
Design and characterisation of the CLICTD pixelated monolithic sensor chip
A novel monolithic pixelated sensor and readout chip, the CLIC Tracker Detector (CLICTD) chip, is presented. The CLICTD chip was designed targeting the requirements of the silicon tracker development for the experiment at the Compact Linear Collider (CLIC), and has been fabricated in a modified 180 nm CMOS imaging process with charge collection on a high-resistivity p-type epitaxial layer. The chip features a matrix of 16×128 elongated channels, each measuring 300×30 μm2. Each channel contains 8 equidistant collection electrodes and analog readout circuits to ensure prompt signal formation. A simultaneous 8-bit Time-of-Arrival (with 10 ns time bins) and 5-bit Time-over-Threshold measurement is performed on the combined digital output of the 8 sub-pixels in every channel. The chip has been fabricated in two process variants and characterised in laboratory measurements using electrical test pulses and radiation sources. Results show a minimum threshold between 135 and 180 e‾ and a noise of about 14 e‾ RMS. The design aspects and characterisation results of the CLICTD chip are presented
Optomechanical resonator-enhanced atom interferometry
Matter-wave interferometry and spectroscopy of optomechanical resonators offer complementary advantages. Interferometry with cold atoms is employed for accurate and long-term stable measurements, yet it is challenged by its dynamic range and cyclic acquisition. Spectroscopy of optomechanical resonators features continuous signals with large dynamic range, however it is generally subject to drifts. In this work, we combine the advantages of both devices. Measuring the motion of a mirror and matter waves interferometrically with respect to a joint reference allows us to operate an atomic gravimeter in a seismically noisy environment otherwise inhibiting readout of its phase. Our method is applicable to a variety of quantum sensors and shows large potential for improvements of both elements by quantum engineering. © 2020, The Author(s)
EUDAQ - A data acquisition software framework for common beam telescopes
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed with reliability and ease-of-use in mind. It enables flexible integration of different independent devices under test via their specific data acquisition systems into a top-level framework. EUDAQ controls all components globally, handles the data flow centrally and synchronises and records the data streams. Over the past decade, EUDAQ has been deployed as part of a wide range of successful test beam campaigns and detector development applications
Recommended from our members
Top-quark physics at the CLIC electron-positron linear collider
Abstract
The Compact Linear Collider (CLIC) is a proposed future high-luminosity linear electron-positron collider operating at three energy stages, with nominal centre-of-mass energies
s
= 380 GeV, 1.5 TeV, and 3 TeV. Its aim is to explore the energy frontier, providing sensitivity to physics beyond the Standard Model (BSM) and precision measurements of Standard Model processes with an emphasis on Higgs boson and top-quark physics. The opportunities for top-quark physics at CLIC are discussed in this paper. The initial stage of operation focuses on top-quark pair production measurements, as well as the search for rare flavour-changing neutral current (FCNC) top-quark decays. It also includes a top-quark pair production threshold scan around 350 GeV which provides a precise measurement of the top-quark mass in a well-defined theoretical framework. At the higher-energy stages, studies are made of top-quark pairs produced in association with other particles. A study of t̄tH production including the extraction of the top Yukawa coupling is presented as well as a study of vector boson fusion (VBF) production, which gives direct access to high-energy electroweak interactions. Operation above 1 TeV leads to more highly collimated jet environments where dedicated methods are used to analyse the jet constituents. These techniques enable studies of the top-quark pair production, and hence the sensitivity to BSM physics, to be extended to higher energies. This paper also includes phenomenological interpretations that may be performed using the results from the extensive top-quark physics programme at CLIC.</jats:p
Top-quark physics at the CLIC electron-positron linear collider
ABSTRACT: The Compact Linear Collider (CLIC) is a proposed future high-luminosity linear electron-positron collider operating at three energy stages, with nominal centre-of-mass energies √s = 380 GeV, 1.5 TeV, and 3 TeV. Its aim is to explore the energy frontier, providing sensitivity to physics beyond the Standard Model (BSM) and precision measurements of Standard Model processes with an emphasis on Higgs boson and top-quark physics. The opportunities for top-quark physics at CLIC are discussed in this paper. The initial stage of operation focuses on top-quark pair production measurements, as well as the search for rare flavour-changing neutral current (FCNC) top-quark decays. It also includes a top-quark pair production threshold scan around 350 GeV which provides a precise measurement of the top-quark mass in a well-defined theoretical framework. At the higher-energy stages, studies are made of top-quark pairs produced in association with other particles. A study of t̄tH production including the extraction of the top Yukawa coupling is presented as well as a study of vector boson fusion (VBF) production, which gives direct access to high-energy electroweak interactions. Operation above 1 TeV leads to more highly collimated jet environments where dedicated methods are used to analyse the jet constituents. These techniques enable studies of the top-quark pair production, and hence the sensitivity to BSM physics, to be extended to higher energies. This paper also includes phenomenological interpretations that may be performed using the results from the extensive top-quark physics programme at CLIC.the Spanish Ministry of Economy, Industry and Competitiveness under projects MINEICO/FEDER-UE, FPA2015-65652-C4-3-R, FPA2015-71292-C2-1-Pand FPA2015-71956-REDT; and the MECD grant FPA2016-78645-P, Spai
Detector Technologies for CLIC
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear
electron-positron collider under development. It is foreseen to be built and
operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3
TeV, respectively. It offers a rich physics program including direct searches
as well as the probing of new physics through a broad set of precision
measurements of Standard Model processes, particularly in the Higgs-boson and
top-quark sectors. The precision required for such measurements and the
specific conditions imposed by the beam dimensions and time structure put
strict requirements on the detector design and technology. This includes
low-mass vertexing and tracking systems with small cells, highly granular
imaging calorimeters, as well as a precise hit-time resolution and power-pulsed
operation for all subsystems. A conceptual design for the CLIC detector system
was published in 2012. Since then, ambitious R&D programmes for silicon vertex
and tracking detectors, as well as for calorimeters have been pursued within
the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector
requirements with innovative technologies. This report introduces the
experimental environment and detector requirements at CLIC and reviews the
current status and future plans for detector technology R&D.Comment: 152 pages, 116 figures; published as CERN Yellow Report Monograph
Vol. 1/2019; corresponding editors: Dominik Dannheim, Katja Kr\"uger, Aharon
Levy, Andreas N\"urnberg, Eva Sickin
- …